[Federal Register Volume 64, Number 70 (Tuesday, April 13, 1999)] [Notices] [Pages 18058-18059] From the Federal Register Online via the Government Publishing Office [www.gpo.gov] [FR Doc No: 99-9170] ----------------------------------------------------------------------- NUCLEAR REGULATORY COMMISSION [Docket Nos. 50-317 and 50-318] In the Matter of Baltimore Gas & Electric Company (Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2); Exemption I. The Baltimore Gas and Electric Company (BGE or the licensee) is the holder of Facility Operating Licenses Nos. DPR-53 and DPR-69, which authorize operation of the Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2 (the facilities), respectively. The licenses provide, among other things, that the facilities are subject to all rules, regulations, and orders of the U.S. Nuclear Regulatory Commission (NRC or the Commission) now or hereafter in effect. The facilities are pressurized-water reactors located at the licensee's site in Calvert County, Maryland. The licensee, in letters dated October 6, 1997, and July 22, 1998, requested an exemption from the technical requirements of 10 CFR Part 50, Appendix R, Section III.J, Emergency lighting, as follows: (1) To be allowed to use security lighting required by 10 CFR 73.55, powered by the security emergency diesel generator, for exterior lighting in lieu of 8-hour battery powered emergency lighting units, (2) to be able to use portable lights powered by an 8-hour power supply, for actions in high radiation areas, in lieu of 8-hour battery powered emergency lighting units, and (3) to be able to use helmet lanterns inside of switchgear cabinets, again in lieu of 8-hour battery powered emergency lighting units. II. Section III.J of Appendix R to 10 CFR Part 50 applies to nuclear power plants that were operating prior to January 1, 1979. Unit 1 of Calvert Cliffs Nuclear Power Plant was licensed to operate July 31, 1974, and Unit 2 was licensed to operate on November 30, 1976. Section III.J of Appendix R specifies that emergency lighting units with at least an 8-hour battery supply shall be provided in all areas needed for operation of safe shutdown equipment and in access and egress routes thereto. The licensee has not provided 8-hour battery supplied emergency lighting units in plant exterior areas, inside of electrical cabinets, or in high radiation areas that require such units under Section III.J. The licensee proposed to credit the security lighting system, required by 10 [[Page 18059]] CFR 73.55, which is backed by a security emergency diesel generator, for exterior lighting in lieu of 8-hour battery powered emergency lighting units. The licensee stated that the security lighting system is powered by an independent, uninterruptible power supply. According to the licensee, the generator backing the security lighting system is located in a separate structure from other plant area buildings and would not be affected by a fire requiring safe shutdown. The licensee stated that the generator is maintained with a fuel supply greater than 8 hours. The licensee also stated that the security lighting system, which meets the illumination requirements of 10 CFR 73.55, provides more than adequate illumination for exterior access and egress routes inside of the security protected area. The licensee also proposed to be able to use portable lights in high radiation areas in lieu of fixed emergency lighting units with at least an 8-hour battery power supply. The exemption to permit this was requested to reduce radiation exposure to levels as low as reasonably achievable (ALARA) by eliminating emergency lighting testing and maintenance in high radiation areas. According to the licensee, the licensee's battery-powered portable lights have a wide base and are designed to be placed on the floor adjacent to the proposed work activity. The position of the lamp head can be adjusted to provide illumination necessary to perform the required work at the activity site. The lights are stored in a controlled cabinet near the activity sites, are dedicated for Appendix R safe shutdown activities, and are periodically tested. The lights have an 8-hour capacity. The licensee stated that fixed emergency lighting units are provided on the access and egress routes to the cabinet which contains the portable lights and to the entrance to the high radiation areas. According to the licensee, activities requiring the use of the portable lights are cold shutdown activities and are not time critical. In addition, the reduction of personnel radiation exposure from maintenance is in accordance with other NRC requirements. The portable lights, according to the licensee, would enable the performance in locked high radiation areas of limited non-time critical safe shutdown activities. Finally, the licensee proposed to be able to use helmet mounted lights inside switchgear cabinets in lieu of fixed emergency lighting units specified by Section III.J of Appendix R. The licensee stated that due to space limitations and seismic qualification requirements, installation of fixed emergency lighting units is not feasible. Emergency lighting units installed outside of the cabinets may not provide adequate lighting for the activity inside of the cabinet due to shadows cast by the operator. Activities performed inside of the cabinets requiring the use of helmet lights are limited to pulling fuses to isolate the cabinet from fire effects, according to the licensee. The helmet lights are stored inside of the Appendix R safe shutdown locker for each unit. This locker also contains the safe shutdown procedures and the locker is the first stop for the operators upon control room evacuation. The helmet mounted lights consist of a light head attached to a wide rubber band that is placed around a hardhat. A belt with two attached battery packs (each weighing about one pound) and a connector to attach the lamps to the battery completes the assembly. The helmet lights for pulling fuses inside of electrical switchgear, according to the licensee, will provide an adequate method of providing the necessary illumination to accomplish the limited activities. III. The underlying purpose of 10 CFR Part 50, Appendix R, Section III.J, is to provide adequate illumination to assure the capability of performing all necessary safe shutdown functions, as well as to assure personnel movement to and from the equipment and components that must be manually operated by plant personnel to effect safe shutdown during emergencies. In addition, the illumination must have a capability to allow sufficient time for normal lighting to be restored. The staff has determined that the security lighting, portable lights, and helmet lights, as described by the licensee and discussed above, satisfy the underlying purpose of 10 CFR Part 50 Appendix R, Section III.J. IV. In consideration of the foregoing, the Commission has determined that pursuant to 10 CFR 50.12, the exemption requested is authorized by law, will not present an undue risk to public health and safety, and is consistent with the common defense and security. The Commission further has determined that special circumstances, as provided in 10 CFR 50.12(a)(2)(ii), are present in that application of the regulation in the particular circumstances is not necessary to achieve the underlying purpose of the rule. Therefore, the licensee's request for an exemption from the requirements of Section III.J of Appendix R to 10 CFR Part 50, to the extent applicable to the areas and locations described by the licensee in its application, is granted, provided the licensee's proposed alternative lighting arrangements are implemented. Pursuant to 10 CFR 51.32, the Commission has determined that granting the above exemption will have no significant impact on the quality of the human environment (64 FR 14275). The subject exemption is effective from the date of issuance. Dated this 7th day of April 1999. For the Nuclear Regulatory Commission. John A. Zwolinski, Director, Division of Licensing Project Management, Office of Nuclear Reactor Regulation. [FR Doc. 99-9170 Filed 4-12-99; 8:45 am] BILLING CODE 7590-01-P
Document
In the Matter of Baltimore Gas & Electric Company (Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2); Exemption
[Federal Register Volume 64, Number 70 (Tuesday, April 13, 1999)] [Notices] [Pages 18058-18059] From the Federal Register Online via the Government Publishing Office [ www.gpo.g...
Legal Citation
Federal Register Citation
Use this for formal legal and research references to the published document.
64 FR 18058
Web Citation
Suggested Web Citation
Use this when citing the archival web version of the document.
“In the Matter of Baltimore Gas & Electric Company (Calvert Cliffs Nuclear Power Plant, Unit Nos. 1 and 2); Exemption,” thefederalregister.org (April 13, 1999), https://thefederalregister.org/documents/99-9170/in-the-matter-of-baltimore-gas-and-electric-company-calvert-cliffs-nuclear-power-plant-unit-nos-1-and-2-exemption.