81_FR_38274 81 FR 38161 - Notice of Petition for Waiver From Johnston Boiler Company From the Department of Energy Commercial Packaged Boiler Test Procedure

81 FR 38161 - Notice of Petition for Waiver From Johnston Boiler Company From the Department of Energy Commercial Packaged Boiler Test Procedure

DEPARTMENT OF ENERGY
Office of Energy Efficiency and Renewable Energy

Federal Register Volume 81, Issue 113 (June 13, 2016)

Page Range38161-38165
FR Document2016-13891

This notice announces receipt of a petition for waiver from Johnston Boiler Company (Johnston) seeking an exemption from specified portions of the U.S. Department of Energy (DOE) test procedure applicable to commercial packaged boilers. Johnston contends that some of their commercial packaged boilers cannot be accurately tested using the currently applicable DOE test procedure and, as a result, seeks to use an alternate test procedure to test these basic models. DOE solicits comments, data, and information concerning Johnston's petition and the suggested alternate test procedure.

Federal Register, Volume 81 Issue 113 (Monday, June 13, 2016)
[Federal Register Volume 81, Number 113 (Monday, June 13, 2016)]
[Notices]
[Pages 38161-38165]
From the Federal Register Online  [www.thefederalregister.org]
[FR Doc No: 2016-13891]


=======================================================================
-----------------------------------------------------------------------

DEPARTMENT OF ENERGY

Office of Energy Efficiency and Renewable Energy

[Case No. BLR-006]


Notice of Petition for Waiver From Johnston Boiler Company From 
the Department of Energy Commercial Packaged Boiler Test Procedure

AGENCY: Office of Energy Efficiency and Renewable Energy, Department of 
Energy.

ACTION: Notice of petition for waiver and request for public comments.

-----------------------------------------------------------------------

SUMMARY: This notice announces receipt of a petition for waiver from 
Johnston Boiler Company (Johnston) seeking an exemption from specified 
portions of the U.S. Department of Energy (DOE) test procedure 
applicable to commercial packaged boilers. Johnston contends that some 
of their commercial packaged boilers cannot be accurately tested using 
the currently applicable DOE test procedure and, as a result, seeks to 
use an alternate test procedure to test these basic models. DOE 
solicits comments, data, and information concerning Johnston's petition 
and the suggested alternate test procedure.

DATES: DOE will accept comments, data, and information with respect to 
the Johnston petition until July 13, 2016.

ADDRESSES: You may submit comments, identified by case number ``BLR-
006,'' by any of the following methods:
     Federal eRulemaking Portal: http://www.regulations.gov. 
Follow the instructions for submitting comments.
     Email: [email protected]. Include the case 
number [Case No. BLR-006] in the subject line of the message.
     Mail: Ms. Brenda Edwards, U.S. Department of Energy, 
Building Technologies Program, Mailstop EE-2B, 1000 Independence Avenue 
SW., Washington, DC 20585-0121. Telephone: (202) 586-2945. Please 
submit one signed original paper copy.
     Hand Delivery/Courier: Ms. Brenda Edwards, U.S. Department 
of Energy, Building Technologies Program, 950 L'Enfant Plaza SW., Suite 
600, Washington, DC 20024. Please submit one signed original paper 
copy.
    Docket: For access to the docket to review the background documents 
relevant to this matter, you may visit http://www.regulations.gov. 
Available documents include the following items: (1) This notice; (2) 
public comments received; and (3) the petition for waiver.

FOR FURTHER INFORMATION CONTACT:
    Mr. Bryan Berringer, U.S. Department of Energy, Building 
Technologies Program, Mail Stop EE-2B, Forrestal Building, 1000 
Independence Avenue SW., Washington, DC 20585-0121. Telephone: (202) 
586-0371. Email: [email protected].
    Mr. Peter Cochran, U.S. Department of Energy, Office of the General 
Counsel, Mail Stop GC-33, Forrestal Building, 1000 Independence Avenue 
SW., Washington, DC 20585-0103. Telephone: (202) 586-9496. Email: 
[email protected].

SUPPLEMENTARY INFORMATION: In a petition received July 21, 2015, 
Johnston requested that the U.S. Department of Energy (``DOE'') grant a 
waiver to certain models of larger commercial package boilers that 
cannot be tested under the existing DOE test procedure. The models of 
commercial packaged boilers at issue are models with higher input 
capacities that typically require higher steam pressure and alternative 
instrumentation due to the large quantities of fluids being measured.

I. Background and Authority

    Title III, Part C of the Energy Policy and Conservation Act of 1975 
(EPCA), as amended (42 U.S.C. 6311 et seq.), established the Energy 
Conservation Program for certain industrial equipment, which includes 
commercial packaged boilers.\1\ Part C specifically includes 
definitions (42 U.S.C. 6311), energy conservation standards (42 U.S.C 
6313), test procedures (42 U.S.C. 6314), labeling provisions (42 U.S.C. 
6315), and the authority to require information and reports from 
manufacturers (42 U.S.C. 6316). Part C authorizes the Secretary of 
Energy (the Secretary) to prescribe test procedures that are reasonably 
designed to produce results that measure energy efficiency, energy use, 
and estimated annual operating costs, and that are not unduly 
burdensome to conduct. (42 U.S.C. 6314(a)(2)) With respect to 
commercial packaged boilers, Part C requires DOE to use industry test 
procedures developed or recognized by the Air-Conditioning, Heating, 
and Refrigeration Institute (AHRI) or the American Society of Heating, 
Refrigerating, and Air-Conditioning Engineers (ASHRAE), as referenced 
in ASHRAE/IES \2\ Standard 90.1, ``Energy Standard for Buildings Except 
Low-Rise Residential Buildings.'' (42 U.S.C. 6314(a)(4)(A)) Further, if 
such an industry test procedure is amended, DOE is required to amend 
its test procedure to be consistent with the amended industry test 
procedure, unless it determines, by rule published

[[Page 38162]]

in the Federal Register and supported by clear and convincing evidence, 
that the amended test procedure would be unduly burdensome to conduct 
or would not produce test results that reflect the energy efficiency, 
energy use, and estimated operating costs of that equipment during a 
representative average use cycle. (42 U.S.C. 6314(a)(4)(B)). The test 
procedure for commercial packaged boilers is contained in 10 CFR part 
431, subpart E.
---------------------------------------------------------------------------

    \1\ For editorial reasons, upon codification in the U.S. Code, 
Part C was re-designated Part A-1.
    \2\ Illuminating Engineering Society.
---------------------------------------------------------------------------

    DOE's regulations for covered products and equipment permit a 
person to seek a waiver from the test procedure requirements for 
covered commercial equipment if at least one of the following 
conditions is met: (1) The petitioner's basic model contains one or 
more design characteristics that prevent testing according to the 
prescribed test procedures; or (2) the prescribed test procedures may 
evaluate the basic model in a manner so unrepresentative of its true 
energy consumption as to provide materially inaccurate comparative 
data. 10 CFR 431.401(a)(1). A petitioner must include in its petition 
any alternate test procedures known to the petitioner to evaluate the 
basic model in a manner representative of its energy consumption. 10 
CFR 431.401(b)(1)(iii).
    DOE may grant a waiver subject to conditions, including adherence 
to alternate test procedures. 10 CFR 431.401(f)(2). As soon as 
practicable after the granting of any waiver, DOE will publish in the 
Federal Register a notice of proposed rulemaking to amend its 
regulations so as to eliminate any need for the continuation of such 
waiver. As soon thereafter as practicable, DOE will publish in the 
Federal Register a final rule. 10 CFR 431.401(l).

II. Petition for Waiver of Test Procedure

    On July 21, 2015, Johnston submitted a petition for waiver from the 
DOE test procedure for certain basic models of its commercial packaged 
boilers. The DOE test procedure for commercial packaged boilers is set 
forth at 10 CFR 431.86 and incorporates by reference Hydronics 
Institute (HI) BTS-2000, ``Method to Determine Efficiency of Commercial 
Space Heating Boilers'' (BTS-2000).
    According to Johnston, there are several issues that make BTS-2000 
incompatible with larger commercial packaged boilers, including those 
identified in its petition for waiver. Johnston stated that the 
requirements to use test conditions specified in BTS-2000 and the 
instrumentation requirements are outdated. Specifically, Johnston 
indicated the following regarding the test conditions:
     The 0 to 2 psig test pressure for steam boilers may be 
adequate for residential and small commercial (cast iron) boilers sized 
[commercial packaged] boilers, however such steam pressures are not 
compatible with large [commercial packaged] boilers as it will cause 
water carryover in large quantities, and an inability to meet design 
water flow rates and firing rates;
     Typically test steam pressures in the range of 10 to 12 
psig are required; and
     Test temperatures defined for hot water [commercial 
packaged] boilers cause thermal shock problems in large [commercial 
packaged] boilers.
    Johnston also indicated the following regarding the instrumentation 
chart in Table 1 of section 6.0, ``Instruments,'' of BTS-2000:
     Steam pressure cannot be measured by mercury manometer as 
the use of mercury in instruments and controls is banned; the correct 
instrument is a Bourdon Tube Gauge for pressures of 0 to 30 psig;
     Large boilers typically fire into a positive pressure 
combustion chamber, thus gas pressure, firebox pressure and vent/flue 
pressure instruments all need to reflect this;
     The use of scales to measure water/condensate/moisture 
flow rates is incompatible with the volume of these fluids being used 
or generated by large [commercial packaged] boilers; water flow meters 
should be used and in the case of moisture content, current practice is 
to use a throttling calorimeter;
     The measurement of carbon dioxide as a means of 
calculating excess air or oxygen is considered obsolete in the large 
[commercial packaged] boiler industry; direct measurement of excess 
oxygen is the preferred method as modern oxygen meters can easily be 
calibrated against the oxygen in the ambient air;
     Carbon Monoxide levels are no longer measured as a 
percentage; the current preferred unit is parts per million (ppm).
    To address these concerns, Johnston proposes to use the newly 
published American National Standards Institute (ANSI)/Air-
Conditioning, Heating, and Refrigeration Institute (AHRI) 1500-2015, 
``Standard for Performance Rating of Commercial Space Heating Boilers'' 
(ANSI/AHRI Standard 1500-2015) in place of BTS-2000. AHRI developed 
ANSI/AHRI Standard 1500-2015 as a replacement for BTS-2000 in order to 
make the test procedure suitable for use with larger commercial 
packaged boilers, as well as improve and clarify the test method. 
Johnston claims that use of this ANSI/AHRI Standard 1500-2015 is 
necessary as it is compatible with the size of commercial packaged 
boilers they manufacture.
    Additionally, for the large commercial packaged boilers capable of 
supplying either steam or hot water identified in this petition, 
Johnston requests that, when determining the combustion efficiency in 
hot water mode based on testing in steam mode only, the combustion 
efficiency rating be determined based on an adjusted combustion 
efficiency. Johnston requests that an adjustment be made to the 
measured stack temperature to be used in calculating combustion 
efficiency based on the relative difference between the flue gas 
temperature and the bulk fluid temperature when operating in steam mode 
as opposed to hot water using the following relationship:

Tstack, hw = (Tstack, steam - Tsat) + 
Tbulk, hw

where Tstack, hw is the stack temperature to be used to 
determine the combustion efficiency in hot water mode, 
Tstack, steam is the measured stack temperature when testing 
on steam, Tsat is the saturation temperature of steam at the 
test pressure, and Tbulk, hw is the temperature of the 
outlet water when testing in hot water mode and is equal to 180 [deg]F. 
According to Johnston, using this adjusted stack temperature to 
calculate combustion efficiency is a more accurate representation of 
the actual efficiency when operating as a hot water commercial packaged 
boiler than simply using combustion efficiency value for steam mode.
    Johnston also requests to use the vertical stack arrangement shown 
on their ``Drawing #327A0040 Johnston Boiler General Arrangement D.O.E. 
Efficiency Test (attachment B).'' DOE's existing test procedure 
incorporates section 7.0 ``Apparatus'' of BTS-2000 with respect to test 
setup including flue connection requirements. (DOE notes that the term 
``flue,'' not ``stack,'' is used throughout its test procedure 
regulations as well as BTS-2000). The flue requirements differ 
depending on the characteristics of the commercial packaged boiler, 
including:
     Whether the unit is oil-fired or gas-fired, and if gas-
fired;
     Whether the unit is direct vent;
     Whether the unit has an input rating of more than 400,000 
Btu/h;
     Whether the unit is discharges vent gases horizontally or 
vertically; and
     Whether the unit is condensing.
    According to Johnston, the large volume of flue gas in relation to 
the flue

[[Page 38163]]

diameter results in relatively high velocities and therefore creates 
turbulence. Johnston indicates that this straight stack arrangement is 
shown in their operating manual and in the American Boiler Manufacturer 
Association's (ABMA) ``Packaged Boiler Engineering Manual.'' DOE 
requests comment on how turbulence affects measured efficiency under 
the current test procedure, and how use of the vertical stack 
arrangement shown in the drawing provided by Johnston would prevent 
turbulence.
    In addition, Johnston stated that ANSI/AHRI Standard 1500-2015 does 
not clarify whether there is an upper limit for fuel input rate to 
which the standard applies. However, the scope of ANSI/AHRI Standard 
1500-2015 is identified as ``commercial space heating boilers'' in 
section 1.1. (Note: The term ``commercial space heating boiler'' is not 
defined in ANSI/AHRI Standard 1500-2015.) Johnston suggested that the 
upper fuel input rate limit be established at 12,500,000 Btu/hr. 
Johnston stated that the two major safety standards for the industry 
are American Society of Mechanical Engineers (ASME) CSD-1 Controls and 
Safety Devices for Automatically Fired Boilers (ASME CSD-1) and 
National Fire Protection Association (NFPA)-85-2015 Boiler and 
Combustion Systems Hazard Code (NFPA-85). Johnston further indicated 
that the scope of ASME CSD-1 is for commercial boilers with inputs from 
400,000 to 12,500,000 Btu/hr and the scope for NFPA-85 is for 
industrial boilers over 12,500,000 Btu/hr. DOE notes that neither the 
existing DOE test procedure or energy standards establish an upper 
limit in terms of fuel input rate for which they apply. Consequently, 
DOE is declining to consider Johnston's request for an upper limit for 
the fuel input rate which would limit the scope of applicability of the 
test procedure in this proceeding.
    DOE notes that it has published a notice of proposed rulemaking 
(NOPR) to amend its test procedure for commercial packaged boilers 
prescribed in 10 CFR part 431 subpart E (March 2016 CPB TP NOPR). 81 FR 
14641 (Mar. 17, 2016). The proposed amended test procedure addresses, 
among other changes, most of the issues raised in this waiver request 
by incorporating by reference ANSI/AHRI Standard 1500-2015 as a 
replacement for BTS-2000 in the DOE test procedure for commercial 
packaged boilers. In addition to adopting ANSI/AHRI Standard 1500-2015 
as a replacement for BTS-2000, DOE further proposes several 
modifications to its test procedure that are not captured in ANSI/AHRI 
Standard 1500-2015 in order to improve repeatability, add 
clarification, and accommodate testing of some equipment that has 
experienced difficulty in testing to the existing DOE test procedure. 
Among these changes, DOE proposes to adopt the stack temperature 
adjustment described by Johnston when using the tested combustion 
efficiency of large steam commercial packaged boilers to represent the 
combustion efficiency of large commercial packaged boilers in hot water 
mode.
    The following basic models are included in Johnston's petition:

------------------------------------------------------------------------
 
------------------------------------------------------------------------
                               509 Series
------------------------------------------------------------------------
                          4-Pass Scotch Marine
------------------------------------------------------------------------
PFT_50-4S                            PFT_50-4W
PFT_75-4S                            PFT_75-4W
PFT_80-4S                            PFT_80-4W
PFT_100-4S                           PFT_100-4W
PFT_125-4S                           PFT_125-4W
PFT_150-4S                           PFT_150-4W
PFT_200-4S                           PFT_200-4W
PFT_250-4S                           PFT_250-4W
PFT_300-4S                           PFT_300-4W
PFT_350-4S                           PFT_350-4W
PFT_400-4S                           PFT_400-4W
PFT_500-4S                           PFT_500-4W
PFT_600-4S                           PFT_600-4W
PFT_750-4S                           PFT_750-4W
PFT_800-4S                           PFT_800-4W
PFT_900-4S                           PFT_900-4W
PFT_1000-4S                          PFT_1000-4W
PFT_1200-4S                          PFT_1200-4W
PFT_1500-4S                          PFT_1500-4W
PFT_1600-4S                          PFT_1600-4W
------------------------------------------------------------------------
                               509 Series
------------------------------------------------------------------------
                          3-Pass Scotch Marine
------------------------------------------------------------------------
PFT_50-3S                            PFT_50-3W
PFT_75-3S                            PFT_75-3W
PFT_80-3S                            PFT_80-3W
PFT_100-3S                           PFT_100-3W
PFT_125-3S                           PFT_125-3W
PFT_150-3S                           PFT_150-3W
PFT_200-3S                           PFT_200-3W
PFT_250-3S                           PFT_250-3W
PFT_300-3S                           PFT_300-3W
PFT_350-3S                           PFT_350-3W
PFT_400-3S                           PFT_400-3W
PFT_500-3S                           PFT_500-3W
PFT_600-3S                           PFT_600-3W
PFT_750-3S                           PFT_750-3W
PFT_800-3S                           PFT_800-3W
PFT_900-3S                           PFT_900-3W
PFT_1000-3S                          PFT_1000-3W
PFT_1200-3S                          PFT_1200-3W
PFT_1500-3S                          PFT_1500-3W
PFT_1600-3S                          PFT_1600-3W
PFT_1800-3S                          PFT_1800-3W
PFT_2000-3S                          PFT_2000-3W
PFT_2500-3S                          PFT_2500-3W
------------------------------------------------------------------------
                               XID Series
------------------------------------------------------------------------
                          2-Pass Scotch Marine
------------------------------------------------------------------------
PFX_100-2S                           PFX_100-2W
PFX_150-2S                           PFX_150-2W
PFX_200-2S                           PFX_200-2W
PFX_250-2S                           PFX_250-2W
PFX_300-2S                           PFX_300-2W
PFX_350-2S                           PFX_350-2W
PFX_400-2S                           PFX_400-2W
PFX_500-2S                           PFX_500-2W
PFX_600-2S                           PFX_600-2W
PFX_700-2S                           PFX_700-2W
PFX_800-2S                           PFX_800-2W
PFX_900-2S                           PFX_900-2W
PFX_1000-2S                          PFX_1000-2W
PFX_1200-2S                          PFX_1200-2W
PFX_1500-2S                          PFX_1500-2W
PFX_1600-2S                          PFX_1600-2W
PFX_1800-2S                          PFX_1800-2W
PFX_2000-2S                          PFX_2000-2W
PFX_2500-2S                          PFX_2500-2W
------------------------------------------------------------------------
                               309 Series
------------------------------------------------------------------------
                          3-Pass Scotch Marine
------------------------------------------------------------------------
PFB_100-3S                           PFB_100-3W
PFB_125-3S                           PFB_125-3W
PFB_150-3S                           PFB_150-3W
PFB_200-3S                           PFB_200-3W
PFB_250-3S                           PFB_250-3W
PFB_300-3S                           PFB_300-3W
PFB_350-3S                           PFB_350-3W
PFB_400-3S                           PFB_400-3W
PFB_500-3S                           PFB_500-3W
PFB_600-3S                           PFB_600-3W
PFB_750-3S                           PFB_750-3W
------------------------------------------------------------------------

III. Summary and Request for Comments

    Through this notice, DOE is publishing Johnston's petition for 
waiver pursuant to 10 CFR 431.401(b)(1)(iv). The petition contains no 
confidential information. The petition includes a suggested alternate 
test procedure applicable to measurement of energy efficiency of 
certain models of commercial packaged boilers manufactured by Johnston.
    DOE solicits comments from interested parties on all aspects of the 
petition, including the suggested alternate test procedure. Pursuant to 
10 CFR 431.401(d), any person submitting written comments to DOE must 
also send a copy of such comments to the petitioner. The contact 
information for the petitioner is: David C. Reinink, President, 
Johnston Boiler Company, 300 Pine Street, P.O. Box 300, Ferrysburg, MI 
49409-0300. All submissions received must include the agency name and 
case number for this proceeding. Submit electronic comments in 
WordPerfect, Microsoft Word, Portable Document Format (PDF), or text 
(American Standard Code for Information Interchange (ASCII)) file 
format and avoid the use of special characters or any form of 
encryption. Wherever possible, include the electronic signature of the 
author. DOE does not accept telefacsimiles (faxes).

[[Page 38164]]

    According to 10 CFR 1004.11, any person submitting information that 
he or she believes to be confidential and exempt by law from public 
disclosure should submit two copies: One copy of the document including 
all the information believed to be confidential, and one copy of the 
document with the information believed to be confidential deleted. DOE 
will make its own determination about the confidential status of the 
information and treat it according to its determination.

    Issued in Washington, DC, on June 3, 2016.
Kathleen B. Hogan,
Deputy Assistant Secretary for Energy Efficiency, Energy Efficiency and 
Renewable Energy.
Johnston Boiler Company
300 Pine Street
P.O. Box 300
Ferrysburg, MI 49409-0300

Application for Waiver for the Efficiency Rating of Commercial Space 
Heating Boilers

    In accordance with the provisions of the Code of Federal 
Regulations Part 431, paragraph 431.401, Johnston Boiler Company is 
hereby petitioning for a waiver from the following test procedures 
specified for Commercial Packaged Boilers:
    1. Paragraph 431.86 Uniform test method for the measurement of 
energy efficiency of commercial packaged boilers. This section 
requires the boilers be tested using the provisions of HI BTS-2000. 
We propose to use the newly published AHRI 1500, 2015 Standard for 
Performance Rating of Commercial Space Heating Boilers. There are 
several issues that make BTS 2000 incompatible with the larger 
boilers that were identified in previous waiver requests. AHRI has 
worked diligently over the past year to revise BTS-2000 in order to 
address those issues and make BTS-2000 suitable for use with larger 
boilers. AHRI Standard 1500 is the result of that work. Use of this 
new standard is required as it is compatible with the size boilers 
we manufacture.
    2. Paragraph 431.86(c)(1)(iv) The requirement to use test 
conditions specified in BTS-2000 specifically the requirements for 
the test pressure for steam boilers, the required water temperatures 
for hot water boilers and instrumentation requirements seem to refer 
back to the middle of the last century rather than the present day, 
for example:
     The 0 to 2 psig test pressure for steam boilers may be 
perfectly adequate for residential and small commercial (cast iron) 
boilers sized boilers, however is not compatible with large boilers 
as it will cause water carryover in large quantities, and an 
inability to meet design water flow rates and firing rates. 
Typically test pressures in range 10 to 12 psig are required.
     Test temperatures defined for hot water boilers are 
guaranteed to cause thermal shock problems in large boilers.
     The instrumentation chart, Table 1, has several problem 
areas, as follows:
    [cir] Steam pressure cannot be measured by mercury manometer as 
the use of mercury in instruments and controls is banned. The 
correct instrument is a Bourdon Tube Gauge 0 to 30 psig
    [cir] Large boilers typically fire into a positive pressure 
combustion chamber, thus gas pressure, firebox pressure and vent/
flue pressure instruments all need to reflect this.
    [cir] The use of scales to measure water/condensate/moisture 
flow rates is incompatible with the sheer volume of these fluids 
being used or generated by large boilers. Water flow meters should 
be used and in the case of moisture content, current practice is to 
use a throttling calorimeter.
    [cir] The measurement of carbon dioxide as a means of 
calculating excess air or oxygen is considered obsolete in the large 
boiler industry. Direct measurement of excess oxygen is the 
preferred method as modern oxygen meters can easily be calibrated 
against the oxygen in the ambient air.
    [cir] Carbon Monoxide levels are no longer measured as a 
percentage. The current preferred unit is ppm.
    AHRI 1500 has taken into account these changes.
    3. Paragraph 431.86(c)(2)(iii)(B) Rating. This paragraph 
specifies that for boilers capable of supplying either steam or hot 
water, that they are tested on steam only, the hot water efficiency 
shall be based on the testing in the steam mode. We propose to use 
an adjusted steam efficiency for hot water when testing on steam 
only. The adjustment is made to the measured stack temperature to be 
used in calculating efficiency based on the relative difference 
between the flue gas temperature and the bulk fluid temperature when 
operating on steam v hot water using the following relationship:

Tstackhw = (Tstacksteam - Tsat) + 
Tbulkhw

Where:

Tstackhw = Stack temperature to be used to determine the 
efficiency on hot water
Tstacksteam = Measured stack temperature when testing on 
steam
Tsat = Saturation temperature of steam at the test 
pressure
Tbulkhw = 180 [deg]F

    The dominant heat transfer variable for both steam and hot water 
boilers is the gas side coefficient and there is very little 
difference in the overall heat transfer coefficient between steam 
and hot water boilers. It is possible therefore to determine what a 
hot water boiler stack temperature will be, based on a steam test 
and the bulk fluid temperature difference within the boiler. We 
believe that using this adjusted stack temperature to calculate 
efficiency is a more accurate representation of the actual 
efficiency when operating as a hot water boiler than simply using 
the steam efficiency value.
    4. We will use the vertical stack arrangement shown on our 
Drawing #327A0040 Johnston Boiler General Arrangement D.O.E. 
Efficiency Test (attachment B). The large volume of our flue gas in 
relation to the flue diameter results in relatively high velocities 
with resulting turbulence. This straight stack arrangement is shown 
in our operating manual and ABMA's ``Packaged Boiler Engineering 
Manual''.
    5. AHRI Standard 1500, Page 1, Section 2, Paragraph 1.1 and 2.2. 
It is not clear if there is an upper limit for input rating. 
However, the stated purpose of the AHRI standard 1500 is for 
Commercial Space Heating Boilers. We suggest that the upper input 
limit be established at 12,500,000 Btu/hr.
    The two major safety standards for our industry are American 
Society of Mechanical Engineers (ASME CSD-1 Controls and Safety 
Devices for Automatically Fired Boilers) and National Fire 
Protection Association (2015 NFPA-85 Boiler and Combustion Systems 
Hazard Code). The scope of CSD-1 is for Commercial Boilers with 
inputs from 400,000 to 12,500,000 Btu/hr. The scope for NFPA-85 is 
for Industrial Boilers over 12,500,000 Btu/hr.
    The basic models that this request is applicable to are as 
follows:

See attachment A

    Other known Manufacturers of similar products are listed below. 
These manufacturers will be notified by Johnston Boiler Company of 
this waiver, if and when the deviation is granted, in accordance 
with paragraph 431.401(c).

AESYS Technologies, LLC
Bryan Steam
Burnham Commercial
Cleaver Brooks
Easco
Fulton Boiler Works
Hurst
Johnston Boiler Company
Lattner Boiler Company
Miura
Precision Boilers LLC
Superior Boiler Works
Unilux
Vapor Power International LLC
Victory Energy Operations LLC
Williams & Davis

Best Regards,

David C. Reinink,
President, Johnston Boiler Company

Attachment A

Johnston Boiler Company--Ferrysburg, Michigan--Boiler Model Numbers

------------------------------------------------------------------------
 
------------------------------------------------------------------------
                               509 Series
------------------------------------------------------------------------
                          4-Pass Scotch Marine
------------------------------------------------------------------------
PFT_50-4S                            PFT_50-4W
PFT_75-4S                            PFT_75-4W
PFT_80-4S                            PFT_80-4W
PFT_100-4S                           PFT_100-4W
PFT_125-4S                           PFT_125-4W
PFT_150-4S                           PFT_150-4W
PFT_200-4S                           PFT_200-4W
PFT_250-4S                           PFT_250-4W
PFT_300-4S                           PFT_300-4W
PFT_350-4S                           PFT_350-4W
PFT_400-4S                           PFT_400-4W
PFT_500-4S                           PFT_500-4W
PFT_600-4S                           PFT_600-4W
PFT_750-4S                           PFT_750-4W
PFT_800-4S                           PFT_800-4W
PFT_900-4S                           PFT_900-4W
PFT_1000-4S                          PFT_1000-4W
PFT_1200-4S                          PFT_1200-4W
PFT_1500-4S                          PFT_1500-4W
PFT_1600-4S                          PFT_1600-4W
------------------------------------------------------------------------

[[Page 38165]]

 
                               509 Series
------------------------------------------------------------------------
                          3-Pass Scotch Marine
------------------------------------------------------------------------
PFT_50-3S                            PFT_50-3W
PFT_75-3S                            PFT_75-3W
PFT_80-3S                            PFT_80-3W
PFT_100-3S                           PFT_100-3W
PFT_125-3S                           PFT_125-3W
PFT_150-3S                           PFT_150-3W
PFT_200-3S                           PFT_200-3W
PFT_250-3S                           PFT_250-3W
PFT_300-3S                           PFT_300-3W
PFT_350-3S                           PFT_350-3W
PFT_400-3S                           PFT_400-3W
PFT_500-3S                           PFT_500-3W
PFT_600-3S                           PFT_600-3W
PFT_750-3S                           PFT_750-3W
PFT_800-3S                           PFT_800-3W
PFT_900-3S                           PFT_900-3W
PFT_1000-3S                          PFT_1000-3W
PFT_1200-3S                          PFT_1200-3W
PFT_1500-3S                          PFT_1500-3W
PFT_1600-3S                          PFT_1600-3W
PFT_1800-3S                          PFT_1800-3W
PFT_2000-3S                          PFT_2000-3W
PFT_2500-3S                          PFT_2500-3W
------------------------------------------------------------------------
                               XID Series
------------------------------------------------------------------------
                          2-Pass Scotch Marine
------------------------------------------------------------------------
PFX_100-2S                           PFX_100-2W
PFX_150-2S                           PFX_150-2W
PFX_200-2S                           PFX_200-2W
PFX_250-2S                           PFX_250-2W
PFX_300-2S                           PFX_300-2W
PFX_350-2S                           PFX_350-2W
PFX_400-2S                           PFX_400-2W
PFX_500-2S                           PFX_500-2W
PFX_600-2S                           PFX_600-2W
PFX_700-2S                           PFX_700-2W
PFX_800-2S                           PFX_800-2W
PFX_900-2S                           PFX_900-2W
PFX_1000-2S                          PFX_1000-2W
PFX_1200-2S                          PFX_1200-2W
PFX_1500-2S                          PFX_1500-2W
PFX_1600-2S                          PFX_1600-2W
PFX_1800-2S                          PFX_1800-2W
PFX_2000-2S                          PFX_2000-2W
PFX_2500-2S                          PFX_2500-2W
------------------------------------------------------------------------
                               309 Series
------------------------------------------------------------------------
                          3-Pass Scotch Marine
------------------------------------------------------------------------
PFB_100-3S                           PFB_100-3W
PFB_125-3S                           PFB_125-3W
PFB_150-3S                           PFB_150-3W
PFB_200-3S                           PFB_200-3W
PFB_250-3S                           PFB_250-3W
PFB_300-3S                           PFB_300-3W
PFB_350-3S                           PFB_350-3W
PFB_400-3S                           PFB_400-3W
PFB_500-3S                           PFB_500-3W
PFB_600-3S                           PFB_600-3W
PFB_750-3S                           PFB_750-3W
------------------------------------------------------------------------

                                     [GRAPHIC] [TIFF OMITTED] TN13JN16.014
                                     
[FR Doc. 2016-13891 Filed 6-10-16; 8:45 am]
BILLING CODE6450-01-P



                                                                               Federal Register / Vol. 81, No. 113 / Monday, June 13, 2016 / Notices                                                       38161

                                                (4) how might the Department enhance                    DEPARTMENT OF ENERGY                                   Program, Mail Stop EE–2B, Forrestal
                                                the quality, utility, and clarity of the                                                                       Building, 1000 Independence Avenue
                                                information to be collected; and (5) how                Office of Energy Efficiency and                        SW., Washington, DC 20585–0121.
                                                might the Department minimize the                       Renewable Energy                                       Telephone: (202) 586–0371. Email:
                                                burden of this collection on the                        [Case No. BLR–006]                                     Bryan.Berringer@ee.doe.gov.
                                                respondents, including through the use                                                                           Mr. Peter Cochran, U.S. Department of
                                                of information technology. Please note                  Notice of Petition for Waiver From                     Energy, Office of the General Counsel,
                                                that written comments received in                       Johnston Boiler Company From the                       Mail Stop GC–33, Forrestal Building,
                                                                                                        Department of Energy Commercial                        1000 Independence Avenue SW.,
                                                response to this notice will be
                                                                                                        Packaged Boiler Test Procedure                         Washington, DC 20585–0103.
                                                considered public records.
                                                                                                                                                               Telephone: (202) 586–9496. Email:
                                                  Title of Collection: Fund for the                     AGENCY:  Office of Energy Efficiency and               Peter.Cochran@hq.doe.gov.
                                                Improvement of Postsecondary                            Renewable Energy, Department of                        SUPPLEMENTARY INFORMATION: In a
                                                Education (FIPSE) Annual Performance                    Energy.                                                petition received July 21, 2015, Johnston
                                                Report.                                                 ACTION: Notice of petition for waiver and              requested that the U.S. Department of
                                                  OMB Control Number: 1840–0793.                        request for public comments.                           Energy (‘‘DOE’’) grant a waiver to
                                                                                                        SUMMARY:    This notice announces receipt              certain models of larger commercial
                                                  Type of Review: A revision of an                                                                             package boilers that cannot be tested
                                                existing information collection.                        of a petition for waiver from Johnston
                                                                                                        Boiler Company (Johnston) seeking an                   under the existing DOE test procedure.
                                                  Respondents/Affected Public: State,                                                                          The models of commercial packaged
                                                                                                        exemption from specified portions of
                                                Local, and Tribal Governments.                                                                                 boilers at issue are models with higher
                                                                                                        the U.S. Department of Energy (DOE)
                                                  Total Estimated Number of Annual                                                                             input capacities that typically require
                                                                                                        test procedure applicable to commercial
                                                Responses: 100.                                                                                                higher steam pressure and alternative
                                                                                                        packaged boilers. Johnston contends
                                                                                                                                                               instrumentation due to the large
                                                  Total Estimated Number of Annual                      that some of their commercial packaged
                                                                                                                                                               quantities of fluids being measured.
                                                Burden Hours: 4,000.                                    boilers cannot be accurately tested using
                                                                                                        the currently applicable DOE test                      I. Background and Authority
                                                  Abstract: The Fund for the                            procedure and, as a result, seeks to use
                                                Improvement of Postsecondary                                                                                      Title III, Part C of the Energy Policy
                                                                                                        an alternate test procedure to test these              and Conservation Act of 1975 (EPCA),
                                                Education (FIPSE) works to improve                      basic models. DOE solicits comments,
                                                postsecondary education through grants                                                                         as amended (42 U.S.C. 6311 et seq.),
                                                                                                        data, and information concerning                       established the Energy Conservation
                                                to postsecondary educational                            Johnston’s petition and the suggested                  Program for certain industrial
                                                institutions and agencies. Such grants                  alternate test procedure.                              equipment, which includes commercial
                                                are awarded to non-profit organizations                 DATES: DOE will accept comments, data,                 packaged boilers.1 Part C specifically
                                                on the basis of competitively reviewed                  and information with respect to the                    includes definitions (42 U.S.C. 6311),
                                                applications submitted to FIPSE under                   Johnston petition until July 13, 2016.                 energy conservation standards (42 U.S.C
                                                the First in the World (FITW) Program.                  ADDRESSES: You may submit comments,                    6313), test procedures (42 U.S.C. 6314),
                                                This collection includes a performance                  identified by case number ‘‘BLR–006,’’                 labeling provisions (42 U.S.C. 6315),
                                                report for use with FITW programs                       by any of the following methods:                       and the authority to require information
                                                84.116F and 84.116X. We request                            • Federal eRulemaking Portal: http://               and reports from manufacturers (42
                                                clearance of one annual performance                     www.regulations.gov. Follow the                        U.S.C. 6316). Part C authorizes the
                                                report for FITW programs 84.116F and                    instructions for submitting comments.                  Secretary of Energy (the Secretary) to
                                                84.116X that will serve the dual purpose                   • Email: AS_Waiver_Requests@                        prescribe test procedures that are
                                                of an annual and final performance                      ee.doe.gov. Include the case number                    reasonably designed to produce results
                                                report. In this collection there is one (1)             [Case No. BLR–006] in the subject line                 that measure energy efficiency, energy
                                                form, the annual performance report for                 of the message.                                        use, and estimated annual operating
                                                FITW programs that includes a FITW                         • Mail: Ms. Brenda Edwards, U.S.                    costs, and that are not unduly
                                                program burden statement. The                           Department of Energy, Building                         burdensome to conduct. (42 U.S.C.
                                                collection of the requested data in the                 Technologies Program, Mailstop EE–2B,                  6314(a)(2)) With respect to commercial
                                                                                                        1000 Independence Avenue SW.,                          packaged boilers, Part C requires DOE to
                                                performance report is necessary for the
                                                                                                        Washington, DC 20585–0121.                             use industry test procedures developed
                                                evaluation and assessment of FITW-
                                                                                                        Telephone: (202) 586–2945. Please                      or recognized by the Air-Conditioning,
                                                funded programs and for assessment of
                                                                                                        submit one signed original paper copy.                 Heating, and Refrigeration Institute
                                                continuation funding for each grantee.                     • Hand Delivery/Courier: Ms. Brenda                 (AHRI) or the American Society of
                                                  Dated: June 8, 2016.                                  Edwards, U.S. Department of Energy,                    Heating, Refrigerating, and Air-
                                                Kate Mullan,                                            Building Technologies Program, 950                     Conditioning Engineers (ASHRAE), as
                                                Acting Director, Information Collection                 L’Enfant Plaza SW., Suite 600,                         referenced in ASHRAE/IES 2 Standard
                                                Clearance Division, Office of the Chief Privacy         Washington, DC 20024. Please submit                    90.1, ‘‘Energy Standard for Buildings
                                                Officer, Office of Management.                          one signed original paper copy.                        Except Low-Rise Residential Buildings.’’
                                                [FR Doc. 2016–13865 Filed 6–10–16; 8:45 am]
                                                                                                           Docket: For access to the docket to                 (42 U.S.C. 6314(a)(4)(A)) Further, if such
                                                                                                        review the background documents                        an industry test procedure is amended,
                                                BILLING CODE 4000–01–P
                                                                                                        relevant to this matter, you may visit
srobinson on DSK5SPTVN1PROD with NOTICES




                                                                                                                                                               DOE is required to amend its test
                                                                                                        http://www.regulations.gov. Available                  procedure to be consistent with the
                                                                                                        documents include the following items:                 amended industry test procedure,
                                                                                                        (1) This notice; (2) public comments                   unless it determines, by rule published
                                                                                                        received; and (3) the petition for waiver.
                                                                                                        FOR FURTHER INFORMATION CONTACT:                         1 For editorial reasons, upon codification in the
                                                                                                          Mr. Bryan Berringer, U.S. Department                 U.S. Code, Part C was re-designated Part A–1.
                                                                                                        of Energy, Building Technologies                         2 Illuminating Engineering Society.




                                           VerDate Sep<11>2014   20:48 Jun 10, 2016   Jkt 238001   PO 00000   Frm 00035   Fmt 4703   Sfmt 4703   E:\FR\FM\13JNN1.SGM   13JNN1


                                                38162                          Federal Register / Vol. 81, No. 113 / Monday, June 13, 2016 / Notices

                                                in the Federal Register and supported                   Johnston indicated the following                       boilers, as well as improve and clarify
                                                by clear and convincing evidence, that                  regarding the test conditions:                         the test method. Johnston claims that
                                                the amended test procedure would be                        • The 0 to 2 psig test pressure for                 use of this ANSI/AHRI Standard 1500–
                                                unduly burdensome to conduct or                         steam boilers may be adequate for                      2015 is necessary as it is compatible
                                                would not produce test results that                     residential and small commercial (cast                 with the size of commercial packaged
                                                reflect the energy efficiency, energy use,              iron) boilers sized [commercial                        boilers they manufacture.
                                                and estimated operating costs of that                   packaged] boilers, however such steam                     Additionally, for the large commercial
                                                equipment during a representative                       pressures are not compatible with large                packaged boilers capable of supplying
                                                average use cycle. (42 U.S.C.                           [commercial packaged] boilers as it will               either steam or hot water identified in
                                                6314(a)(4)(B)). The test procedure for                  cause water carryover in large                         this petition, Johnston requests that,
                                                commercial packaged boilers is                          quantities, and an inability to meet                   when determining the combustion
                                                contained in 10 CFR part 431, subpart                   design water flow rates and firing rates;              efficiency in hot water mode based on
                                                E.                                                         • Typically test steam pressures in                 testing in steam mode only, the
                                                   DOE’s regulations for covered                        the range of 10 to 12 psig are required;               combustion efficiency rating be
                                                products and equipment permit a                         and                                                    determined based on an adjusted
                                                person to seek a waiver from the test                      • Test temperatures defined for hot                 combustion efficiency. Johnston
                                                procedure requirements for covered                      water [commercial packaged] boilers                    requests that an adjustment be made to
                                                commercial equipment if at least one of                 cause thermal shock problems in large                  the measured stack temperature to be
                                                the following conditions is met: (1) The                [commercial packaged] boilers.                         used in calculating combustion
                                                petitioner’s basic model contains one or                   Johnston also indicated the following               efficiency based on the relative
                                                more design characteristics that prevent                regarding the instrumentation chart in                 difference between the flue gas
                                                testing according to the prescribed test                Table 1 of section 6.0, ‘‘Instruments,’’ of            temperature and the bulk fluid
                                                procedures; or (2) the prescribed test                  BTS–2000:                                              temperature when operating in steam
                                                                                                           • Steam pressure cannot be measured                 mode as opposed to hot water using the
                                                procedures may evaluate the basic
                                                                                                        by mercury manometer as the use of                     following relationship:
                                                model in a manner so unrepresentative
                                                                                                        mercury in instruments and controls is
                                                of its true energy consumption as to                                                                           Tstack, hw = (Tstack, steam ¥ Tsat) + Tbulk, hw
                                                                                                        banned; the correct instrument is a
                                                provide materially inaccurate                                                                                  where Tstack, hw is the stack temperature
                                                                                                        Bourdon Tube Gauge for pressures of 0
                                                comparative data. 10 CFR 431.401(a)(1).                                                                        to be used to determine the combustion
                                                                                                        to 30 psig;
                                                A petitioner must include in its petition                  • Large boilers typically fire into a               efficiency in hot water mode, Tstack, steam
                                                any alternate test procedures known to                  positive pressure combustion chamber,                  is the measured stack temperature when
                                                the petitioner to evaluate the basic                    thus gas pressure, firebox pressure and                testing on steam, Tsat is the saturation
                                                model in a manner representative of its                 vent/flue pressure instruments all need                temperature of steam at the test
                                                energy consumption. 10 CFR                              to reflect this;                                       pressure, and Tbulk, hw is the temperature
                                                431.401(b)(1)(iii).                                        • The use of scales to measure water/               of the outlet water when testing in hot
                                                   DOE may grant a waiver subject to                    condensate/moisture flow rates is                      water mode and is equal to 180 °F.
                                                conditions, including adherence to                      incompatible with the volume of these                  According to Johnston, using this
                                                alternate test procedures. 10 CFR                       fluids being used or generated by large                adjusted stack temperature to calculate
                                                431.401(f)(2). As soon as practicable                   [commercial packaged] boilers; water                   combustion efficiency is a more
                                                after the granting of any waiver, DOE                   flow meters should be used and in the                  accurate representation of the actual
                                                will publish in the Federal Register a                  case of moisture content, current                      efficiency when operating as a hot water
                                                notice of proposed rulemaking to amend                  practice is to use a throttling                        commercial packaged boiler than simply
                                                its regulations so as to eliminate any                  calorimeter;                                           using combustion efficiency value for
                                                need for the continuation of such                          • The measurement of carbon dioxide                 steam mode.
                                                waiver. As soon thereafter as                           as a means of calculating excess air or                   Johnston also requests to use the
                                                practicable, DOE will publish in the                    oxygen is considered obsolete in the                   vertical stack arrangement shown on
                                                Federal Register a final rule. 10 CFR                   large [commercial packaged] boiler                     their ‘‘Drawing #327A0040 Johnston
                                                431.401(l).                                             industry; direct measurement of excess                 Boiler General Arrangement D.O.E.
                                                II. Petition for Waiver of Test Procedure               oxygen is the preferred method as                      Efficiency Test (attachment B).’’ DOE’s
                                                                                                        modern oxygen meters can easily be                     existing test procedure incorporates
                                                  On July 21, 2015, Johnston submitted                  calibrated against the oxygen in the                   section 7.0 ‘‘Apparatus’’ of BTS–2000
                                                a petition for waiver from the DOE test                 ambient air;                                           with respect to test setup including flue
                                                procedure for certain basic models of its                  • Carbon Monoxide levels are no                     connection requirements. (DOE notes
                                                commercial packaged boilers. The DOE                    longer measured as a percentage; the                   that the term ‘‘flue,’’ not ‘‘stack,’’ is used
                                                test procedure for commercial packaged                  current preferred unit is parts per                    throughout its test procedure
                                                boilers is set forth at 10 CFR 431.86 and               million (ppm).                                         regulations as well as BTS–2000). The
                                                incorporates by reference Hydronics                        To address these concerns, Johnston                 flue requirements differ depending on
                                                Institute (HI) BTS–2000, ‘‘Method to                    proposes to use the newly published                    the characteristics of the commercial
                                                Determine Efficiency of Commercial                      American National Standards Institute                  packaged boiler, including:
                                                Space Heating Boilers’’ (BTS–2000).                     (ANSI)/Air-Conditioning, Heating, and                     • Whether the unit is oil-fired or gas-
                                                  According to Johnston, there are                      Refrigeration Institute (AHRI) 1500–                   fired, and if gas-fired;
                                                several issues that make BTS–2000                       2015, ‘‘Standard for Performance Rating                   • Whether the unit is direct vent;
srobinson on DSK5SPTVN1PROD with NOTICES




                                                incompatible with larger commercial                     of Commercial Space Heating Boilers’’                     • Whether the unit has an input
                                                packaged boilers, including those                       (ANSI/AHRI Standard 1500–2015) in                      rating of more than 400,000 Btu/h;
                                                identified in its petition for waiver.                  place of BTS–2000. AHRI developed                         • Whether the unit is discharges vent
                                                Johnston stated that the requirements to                ANSI/AHRI Standard 1500–2015 as a                      gases horizontally or vertically; and
                                                use test conditions specified in BTS–                   replacement for BTS–2000 in order to                      • Whether the unit is condensing.
                                                2000 and the instrumentation                            make the test procedure suitable for use                  According to Johnston, the large
                                                requirements are outdated. Specifically,                with larger commercial packaged                        volume of flue gas in relation to the flue


                                           VerDate Sep<11>2014   20:48 Jun 10, 2016   Jkt 238001   PO 00000   Frm 00036   Fmt 4703   Sfmt 4703   E:\FR\FM\13JNN1.SGM   13JNN1


                                                                               Federal Register / Vol. 81, No. 113 / Monday, June 13, 2016 / Notices                                              38163

                                                diameter results in relatively high                     Standard 1500–2015 in order to improve                 PFX_150–2S             PFX_150–2W
                                                velocities and therefore creates                        repeatability, add clarification, and                  PFX_200–2S             PFX_200–2W
                                                turbulence. Johnston indicates that this                accommodate testing of some                            PFX_250–2S             PFX_250–2W
                                                straight stack arrangement is shown in                  equipment that has experienced                         PFX_300–2S             PFX_300–2W
                                                                                                                                                               PFX_350–2S             PFX_350–2W
                                                their operating manual and in the                       difficulty in testing to the existing DOE              PFX_400–2S             PFX_400–2W
                                                American Boiler Manufacturer                            test procedure. Among these changes,                   PFX_500–2S             PFX_500–2W
                                                Association’s (ABMA) ‘‘Packaged Boiler                  DOE proposes to adopt the stack                        PFX_600–2S             PFX_600–2W
                                                Engineering Manual.’’ DOE requests                      temperature adjustment described by                    PFX_700–2S             PFX_700–2W
                                                comment on how turbulence affects                       Johnston when using the tested                         PFX_800–2S             PFX_800–2W
                                                measured efficiency under the current                   combustion efficiency of large steam                   PFX_900–2S             PFX_900–2W
                                                test procedure, and how use of the                      commercial packaged boilers to                         PFX_1000–2S            PFX_1000–2W
                                                vertical stack arrangement shown in the                 represent the combustion efficiency of                 PFX_1200–2S            PFX_1200–2W
                                                drawing provided by Johnston would                      large commercial packaged boilers in                   PFX_1500–2S            PFX_1500–2W
                                                prevent turbulence.                                                                                            PFX_1600–2S            PFX_1600–2W
                                                                                                        hot water mode.                                        PFX_1800–2S            PFX_1800–2W
                                                   In addition, Johnston stated that                      The following basic models are                       PFX_2000–2S            PFX_2000–2W
                                                ANSI/AHRI Standard 1500–2015 does                       included in Johnston’s petition:                       PFX_2500–2S            PFX_2500–2W
                                                not clarify whether there is an upper
                                                limit for fuel input rate to which the                                       509 Series                                         309 Series
                                                standard applies. However, the scope of
                                                ANSI/AHRI Standard 1500–2015 is                                       4-Pass Scotch Marine                                 3-Pass Scotch Marine
                                                identified as ‘‘commercial space heating
                                                boilers’’ in section 1.1. (Note: The term               PFT_50–4S                    PFT_50–4W                 PFB_100–3S             PFB_100–3W
                                                                                                        PFT_75–4S                    PFT_75–4W                 PFB_125–3S             PFB_125–3W
                                                ‘‘commercial space heating boiler’’ is                  PFT_80–4S                    PFT_80–4W                 PFB_150–3S             PFB_150–3W
                                                not defined in ANSI/AHRI Standard                       PFT_100–4S                   PFT_100–4W                PFB_200–3S             PFB_200–3W
                                                1500–2015.) Johnston suggested that the                 PFT_125–4S                   PFT_125–4W                PFB_250–3S             PFB_250–3W
                                                upper fuel input rate limit be                          PFT_150–4S                   PFT_150–4W                PFB_300–3S             PFB_300–3W
                                                established at 12,500,000 Btu/hr.                       PFT_200–4S                   PFT_200–4W                PFB_350–3S             PFB_350–3W
                                                Johnston stated that the two major safety               PFT_250–4S                   PFT_250–4W                PFB_400–3S             PFB_400–3W
                                                standards for the industry are American                 PFT_300–4S                   PFT_300–4W                PFB_500–3S             PFB_500–3W
                                                Society of Mechanical Engineers                         PFT_350–4S                   PFT_350–4W                PFB_600–3S             PFB_600–3W
                                                                                                        PFT_400–4S                   PFT_400–4W                PFB_750–3S             PFB_750–3W
                                                (ASME) CSD–1 Controls and Safety                        PFT_500–4S                   PFT_500–4W
                                                Devices for Automatically Fired Boilers                 PFT_600–4S                   PFT_600–4W
                                                (ASME CSD–1) and National Fire                          PFT_750–4S                   PFT_750–4W                III. Summary and Request for
                                                Protection Association (NFPA)–85–2015                   PFT_800–4S                   PFT_800–4W                Comments
                                                Boiler and Combustion Systems Hazard                    PFT_900–4S                   PFT_900–4W                   Through this notice, DOE is
                                                Code (NFPA–85). Johnston further                        PFT_1000–4S                  PFT_1000–4W
                                                                                                                                                               publishing Johnston’s petition for
                                                indicated that the scope of ASME CSD–                   PFT_1200–4S                  PFT_1200–4W
                                                                                                        PFT_1500–4S                  PFT_1500–4W               waiver pursuant to 10 CFR
                                                1 is for commercial boilers with inputs                                                                        431.401(b)(1)(iv). The petition contains
                                                from 400,000 to 12,500,000 Btu/hr and                   PFT_1600–4S                  PFT_1600–4W
                                                                                                                                                               no confidential information. The
                                                the scope for NFPA–85 is for industrial                                      509 Series                        petition includes a suggested alternate
                                                boilers over 12,500,000 Btu/hr. DOE
                                                                                                                                                               test procedure applicable to
                                                notes that neither the existing DOE test                              3-Pass Scotch Marine                     measurement of energy efficiency of
                                                procedure or energy standards establish
                                                                                                        PFT_50–3S                    PFT_50–3W                 certain models of commercial packaged
                                                an upper limit in terms of fuel input rate
                                                                                                        PFT_75–3S                    PFT_75–3W                 boilers manufactured by Johnston.
                                                for which they apply. Consequently,
                                                DOE is declining to consider Johnston’s                 PFT_80–3S                    PFT_80–3W                    DOE solicits comments from
                                                                                                        PFT_100–3S                   PFT_100–3W                interested parties on all aspects of the
                                                request for an upper limit for the fuel                 PFT_125–3S                   PFT_125–3W
                                                input rate which would limit the scope                                                                         petition, including the suggested
                                                                                                        PFT_150–3S                   PFT_150–3W                alternate test procedure. Pursuant to 10
                                                of applicability of the test procedure in               PFT_200–3S                   PFT_200–3W
                                                this proceeding.                                        PFT_250–3S                   PFT_250–3W
                                                                                                                                                               CFR 431.401(d), any person submitting
                                                   DOE notes that it has published a                    PFT_300–3S                   PFT_300–3W                written comments to DOE must also
                                                notice of proposed rulemaking (NOPR)                    PFT_350–3S                   PFT_350–3W                send a copy of such comments to the
                                                to amend its test procedure for                         PFT_400–3S                   PFT_400–3W                petitioner. The contact information for
                                                commercial packaged boilers prescribed                  PFT_500–3S                   PFT_500–3W                the petitioner is: David C. Reinink,
                                                in 10 CFR part 431 subpart E (March                     PFT_600–3S                   PFT_600–3W                President, Johnston Boiler Company,
                                                2016 CPB TP NOPR). 81 FR 14641 (Mar.                    PFT_750–3S                   PFT_750–3W                300 Pine Street, P.O. Box 300,
                                                                                                        PFT_800–3S                   PFT_800–3W                Ferrysburg, MI 49409–0300. All
                                                17, 2016). The proposed amended test                    PFT_900–3S                   PFT_900–3W
                                                procedure addresses, among other                                                                               submissions received must include the
                                                                                                        PFT_1000–3S                  PFT_1000–3W
                                                changes, most of the issues raised in this              PFT_1200–3S                  PFT_1200–3W               agency name and case number for this
                                                waiver request by incorporating by                      PFT_1500–3S                  PFT_1500–3W               proceeding. Submit electronic
                                                reference ANSI/AHRI Standard 1500–                      PFT_1600–3S                  PFT_1600–3W               comments in WordPerfect, Microsoft
                                                2015 as a replacement for BTS–2000 in                   PFT_1800–3S                  PFT_1800–3W               Word, Portable Document Format (PDF),
srobinson on DSK5SPTVN1PROD with NOTICES




                                                the DOE test procedure for commercial                   PFT_2000–3S                  PFT_2000–3W               or text (American Standard Code for
                                                packaged boilers. In addition to                        PFT_2500–3S                  PFT_2500–3W               Information Interchange (ASCII)) file
                                                adopting ANSI/AHRI Standard 1500–                                                                              format and avoid the use of special
                                                                                                                             XID Series
                                                2015 as a replacement for BTS–2000,                                                                            characters or any form of encryption.
                                                DOE further proposes several                                          2-Pass Scotch Marine                     Wherever possible, include the
                                                modifications to its test procedure that                                                                       electronic signature of the author. DOE
                                                are not captured in ANSI/AHRI                           PFX_100–2S                   PFX_100–2W                does not accept telefacsimiles (faxes).


                                           VerDate Sep<11>2014   20:48 Jun 10, 2016   Jkt 238001   PO 00000   Frm 00037   Fmt 4703   Sfmt 4703   E:\FR\FM\13JNN1.SGM   13JNN1


                                                38164                          Federal Register / Vol. 81, No. 113 / Monday, June 13, 2016 / Notices

                                                  According to 10 CFR 1004.11, any                      instruments and controls is banned. The                is an upper limit for input rating. However,
                                                person submitting information that he                   correct instrument is a Bourdon Tube Gauge             the stated purpose of the AHRI standard 1500
                                                or she believes to be confidential and                  0 to 30 psig                                           is for Commercial Space Heating Boilers. We
                                                                                                           Æ Large boilers typically fire into a positive      suggest that the upper input limit be
                                                exempt by law from public disclosure                    pressure combustion chamber, thus gas                  established at 12,500,000 Btu/hr.
                                                should submit two copies: One copy of                   pressure, firebox pressure and vent/flue                  The two major safety standards for our
                                                the document including all the                          pressure instruments all need to reflect this.         industry are American Society of Mechanical
                                                information believed to be confidential,                   Æ The use of scales to measure water/               Engineers (ASME CSD–1 Controls and Safety
                                                and one copy of the document with the                   condensate/moisture flow rates is                      Devices for Automatically Fired Boilers) and
                                                information believed to be confidential                 incompatible with the sheer volume of these            National Fire Protection Association (2015
                                                deleted. DOE will make its own                          fluids being used or generated by large                NFPA–85 Boiler and Combustion Systems
                                                                                                        boilers. Water flow meters should be used              Hazard Code). The scope of CSD–1 is for
                                                determination about the confidential
                                                                                                        and in the case of moisture content, current           Commercial Boilers with inputs from 400,000
                                                status of the information and treat it                  practice is to use a throttling calorimeter.
                                                according to its determination.                                                                                to 12,500,000 Btu/hr. The scope for NFPA–
                                                                                                           Æ The measurement of carbon dioxide as a
                                                                                                                                                               85 is for Industrial Boilers over 12,500,000
                                                   Issued in Washington, DC, on June 3, 2016.           means of calculating excess air or oxygen is
                                                                                                                                                               Btu/hr.
                                                Kathleen B. Hogan,                                      considered obsolete in the large boiler
                                                                                                                                                                  The basic models that this request is
                                                                                                        industry. Direct measurement of excess
                                                Deputy Assistant Secretary for Energy                   oxygen is the preferred method as modern               applicable to are as follows:
                                                Efficiency, Energy Efficiency and Renewable             oxygen meters can easily be calibrated                 See attachment A
                                                Energy.                                                 against the oxygen in the ambient air.                    Other known Manufacturers of similar
                                                Johnston Boiler Company                                    Æ Carbon Monoxide levels are no longer              products are listed below. These
                                                300 Pine Street                                         measured as a percentage. The current                  manufacturers will be notified by Johnston
                                                P.O. Box 300                                            preferred unit is ppm.                                 Boiler Company of this waiver, if and when
                                                Ferrysburg, MI 49409–0300                                  AHRI 1500 has taken into account these              the deviation is granted, in accordance with
                                                Application for Waiver for the Efficiency               changes.                                               paragraph 431.401(c).
                                                      Rating of Commercial Space Heating                   3. Paragraph 431.86(c)(2)(iii)(B) Rating.
                                                                                                                                                               AESYS Technologies, LLC
                                                      Boilers                                           This paragraph specifies that for boilers
                                                                                                                                                               Bryan Steam
                                                   In accordance with the provisions of the             capable of supplying either steam or hot
                                                                                                                                                               Burnham Commercial
                                                Code of Federal Regulations Part 431,                   water, that they are tested on steam only, the
                                                                                                        hot water efficiency shall be based on the             Cleaver Brooks
                                                paragraph 431.401, Johnston Boiler Company                                                                     Easco
                                                is hereby petitioning for a waiver from the             testing in the steam mode. We propose to use
                                                                                                        an adjusted steam efficiency for hot water             Fulton Boiler Works
                                                following test procedures specified for                                                                        Hurst
                                                Commercial Packaged Boilers:                            when testing on steam only. The adjustment
                                                                                                        is made to the measured stack temperature to           Johnston Boiler Company
                                                   1. Paragraph 431.86 Uniform test method                                                                     Lattner Boiler Company
                                                for the measurement of energy efficiency of             be used in calculating efficiency based on the
                                                                                                        relative difference between the flue gas               Miura
                                                commercial packaged boilers. This section
                                                                                                        temperature and the bulk fluid temperature             Precision Boilers LLC
                                                requires the boilers be tested using the
                                                                                                        when operating on steam v hot water using              Superior Boiler Works
                                                provisions of HI BTS–2000. We propose to
                                                                                                        the following relationship:                            Unilux
                                                use the newly published AHRI 1500, 2015
                                                Standard for Performance Rating of                      Tstackhw = (Tstacksteam ¥ Tsat) + Tbulkhw              Vapor Power International LLC
                                                Commercial Space Heating Boilers. There are                                                                    Victory Energy Operations LLC
                                                                                                        Where:                                                 Williams & Davis
                                                several issues that make BTS 2000
                                                                                                        Tstackhw = Stack temperature to be used to             Best Regards,
                                                incompatible with the larger boilers that were
                                                                                                              determine the efficiency on hot water
                                                identified in previous waiver requests. AHRI                                                                   David C. Reinink,
                                                                                                        Tstacksteam = Measured stack temperature
                                                has worked diligently over the past year to                                                                    President, Johnston Boiler Company
                                                                                                              when testing on steam
                                                revise BTS–2000 in order to address those
                                                                                                        Tsat = Saturation temperature of steam at the          Attachment A
                                                issues and make BTS–2000 suitable for use
                                                                                                              test pressure
                                                with larger boilers. AHRI Standard 1500 is                                                                     Johnston Boiler Company—Ferrysburg,
                                                the result of that work. Use of this new                Tbulkhw = 180 °F
                                                                                                                                                               Michigan—Boiler Model Numbers
                                                standard is required as it is compatible with              The dominant heat transfer variable for
                                                the size boilers we manufacture.                        both steam and hot water boilers is the gas
                                                                                                        side coefficient and there is very little                               509 Series
                                                   2. Paragraph 431.86(c)(1)(iv) The
                                                requirement to use test conditions specified            difference in the overall heat transfer
                                                                                                        coefficient between steam and hot water                            4-Pass Scotch Marine
                                                in BTS–2000 specifically the requirements
                                                for the test pressure for steam boilers, the            boilers. It is possible therefore to determine
                                                                                                        what a hot water boiler stack temperature              PFT_50–4S              PFT_50–4W
                                                required water temperatures for hot water
                                                                                                        will be, based on a steam test and the bulk            PFT_75–4S              PFT_75–4W
                                                boilers and instrumentation requirements
                                                                                                        fluid temperature difference within the                PFT_80–4S              PFT_80–4W
                                                seem to refer back to the middle of the last
                                                century rather than the present day, for                boiler. We believe that using this adjusted            PFT_100–4S             PFT_100–4W
                                                example:                                                stack temperature to calculate efficiency is a         PFT_125–4S             PFT_125–4W
                                                   • The 0 to 2 psig test pressure for steam            more accurate representation of the actual             PFT_150–4S             PFT_150–4W
                                                boilers may be perfectly adequate for                   efficiency when operating as a hot water               PFT_200–4S             PFT_200–4W
                                                residential and small commercial (cast iron)            boiler than simply using the steam efficiency          PFT_250–4S             PFT_250–4W
                                                boilers sized boilers, however is not                   value.                                                 PFT_300–4S             PFT_300–4W
                                                compatible with large boilers as it will cause             4. We will use the vertical stack                   PFT_350–4S             PFT_350–4W
                                                water carryover in large quantities, and an             arrangement shown on our Drawing                       PFT_400–4S             PFT_400–4W
                                                inability to meet design water flow rates and           #327A0040 Johnston Boiler General                      PFT_500–4S             PFT_500–4W
                                                firing rates. Typically test pressures in range         Arrangement D.O.E. Efficiency Test                     PFT_600–4S             PFT_600–4W
srobinson on DSK5SPTVN1PROD with NOTICES




                                                10 to 12 psig are required.                             (attachment B). The large volume of our flue           PFT_750–4S             PFT_750–4W
                                                   • Test temperatures defined for hot water            gas in relation to the flue diameter results in        PFT_800–4S             PFT_800–4W
                                                boilers are guaranteed to cause thermal shock           relatively high velocities with resulting              PFT_900–4S             PFT_900–4W
                                                problems in large boilers.                              turbulence. This straight stack arrangement is         PFT_1000–4S            PFT_1000–4W
                                                   • The instrumentation chart, Table 1, has            shown in our operating manual and ABMA’s               PFT_1200–4S            PFT_1200–4W
                                                several problem areas, as follows:                      ‘‘Packaged Boiler Engineering Manual’’.                PFT_1500–4S            PFT_1500–4W
                                                   Æ Steam pressure cannot be measured by                  5. AHRI Standard 1500, Page 1, Section 2,           PFT_1600–4S            PFT_1600–4W
                                                mercury manometer as the use of mercury in              Paragraph 1.1 and 2.2. It is not clear if there



                                           VerDate Sep<11>2014   20:48 Jun 10, 2016   Jkt 238001   PO 00000   Frm 00038   Fmt 4703   Sfmt 4703   E:\FR\FM\13JNN1.SGM   13JNN1


                                                                               Federal Register / Vol. 81, No. 113 / Monday, June 13, 2016 / Notices                                              38165

                                                                    509 Series                          PFT_1600–3S                  PFT_1600–3W               PFX_1500–2S            PFX_1500–2W
                                                                                                        PFT_1800–3S                  PFT_1800–3W               PFX_1600–2S            PFX_1600–2W
                                                             3-Pass Scotch Marine                       PFT_2000–3S                  PFT_2000–3W               PFX_1800–2S            PFX_1800–2W
                                                                                                        PFT_2500–3S                  PFT_2500–3W               PFX_2000–2S            PFX_2000–2W
                                                PFT_50–3S                  PFT_50–3W
                                                                                                                                                               PFX_2500–2S            PFX_2500–2W
                                                PFT_75–3S                  PFT_75–3W                                         XID Series
                                                PFT_80–3S                  PFT_80–3W
                                                                                                                                                                                309 Series
                                                PFT_100–3S                 PFT_100–3W                                 2-Pass Scotch Marine
                                                PFT_125–3S                 PFT_125–3W
                                                                                                        PFX_100–2S                   PFX_100–2W                            3-Pass Scotch Marine
                                                PFT_150–3S                 PFT_150–3W
                                                PFT_200–3S                 PFT_200–3W                   PFX_150–2S                   PFX_150–2W
                                                PFT_250–3S                 PFT_250–3W                   PFX_200–2S                   PFX_200–2W                PFB_100–3S             PFB_100–3W
                                                PFT_300–3S                 PFT_300–3W                   PFX_250–2S                   PFX_250–2W                PFB_125–3S             PFB_125–3W
                                                PFT_350–3S                 PFT_350–3W                   PFX_300–2S                   PFX_300–2W                PFB_150–3S             PFB_150–3W
                                                PFT_400–3S                 PFT_400–3W                   PFX_350–2S                   PFX_350–2W                PFB_200–3S             PFB_200–3W
                                                PFT_500–3S                 PFT_500–3W                   PFX_400–2S                   PFX_400–2W                PFB_250–3S             PFB_250–3W
                                                PFT_600–3S                 PFT_600–3W                   PFX_500–2S                   PFX_500–2W                PFB_300–3S             PFB_300–3W
                                                PFT_750–3S                 PFT_750–3W                   PFX_600–2S                   PFX_600–2W                PFB_350–3S             PFB_350–3W
                                                PFT_800–3S                 PFT_800–3W                   PFX_700–2S                   PFX_700–2W                PFB_400–3S             PFB_400–3W
                                                PFT_900–3S                 PFT_900–3W                   PFX_800–2S                   PFX_800–2W                PFB_500–3S             PFB_500–3W
                                                PFT_1000–3S                PFT_1000–3W                  PFX_900–2S                   PFX_900–2W                PFB_600–3S             PFB_600–3W
                                                PFT_1200–3S                PFT_1200–3W                  PFX_1000–2S                  PFX_1000–2W               PFB_750–3S             PFB_750–3W
                                                PFT_1500–3S                PFT_1500–3W                  PFX_1200–2S                  PFX_1200–2W




                                                [FR Doc. 2016–13891 Filed 6–10–16; 8:45 am]             DEPARTMENT OF ENERGY                                     Applicants: West Valley Power, LLC.
                                                BILLING CODE6450–01–P                                                                                            Description: West Valley Power, LLC
                                                                                                        Federal Energy Regulatory                              Response to Commission May 25, 2016
srobinson on DSK5SPTVN1PROD with NOTICES




                                                                                                        Commission                                             Data Request.
                                                                                                                                                                 Filed Date: 6/3/16.
                                                                                                        Combined Notice of Filings #1
                                                                                                                                                                 Accession Number: 20160603–5288.
                                                                                                           Take notice that the Commission                       Comments Due: 5 p.m. ET 6/13/16.
                                                                                                        received the following electric corporate                Docket Numbers: EC16–127–000.
                                                                                                        filings:                                                 Applicants: Verso Corporation, Verso
                                                                                                           Docket Numbers: EC16–112–000.                       Maine Energy LLC, Rumford Paper
                                                                                                                                                                                                          EN13JN16.014</GPH>




                                           VerDate Sep<11>2014   20:48 Jun 10, 2016   Jkt 238001   PO 00000   Frm 00039   Fmt 4703   Sfmt 4703   E:\FR\FM\13JNN1.SGM   13JNN1



Document Created: 2018-02-08 07:39:35
Document Modified: 2018-02-08 07:39:35
CategoryRegulatory Information
CollectionFederal Register
sudoc ClassAE 2.7:
GS 4.107:
AE 2.106:
PublisherOffice of the Federal Register, National Archives and Records Administration
SectionNotices
ActionNotice of petition for waiver and request for public comments.
DatesDOE will accept comments, data, and information with respect to the Johnston petition until July 13, 2016.
ContactMr. Bryan Berringer, U.S. Department of Energy, Building Technologies Program, Mail Stop EE-2B, Forrestal Building, 1000 Independence Avenue SW., Washington, DC 20585-0121. Telephone: (202) 586-0371. Email: [email protected]
FR Citation81 FR 38161 