83_FR_17645 83 FR 17568 - Underwriters Laboratories, Inc.: Applications for Expansion of Recognition and Proposed Modification To Update the Nationally Recognized Testing Laboratory (NRTL) Program's List of Appropriate Test Standards

83 FR 17568 - Underwriters Laboratories, Inc.: Applications for Expansion of Recognition and Proposed Modification To Update the Nationally Recognized Testing Laboratory (NRTL) Program's List of Appropriate Test Standards

DEPARTMENT OF LABOR
Occupational Safety and Health Administration

Federal Register Volume 83, Issue 77 (April 20, 2018)

Page Range17568-17571
FR Document2018-08256

In this notice, OSHA announces the applications of Underwriters Laboratories, Inc., for expansion of its scope of recognition as a Nationally Recognized Testing Laboratory and presents the Agency's preliminary finding to grant the applications. Additionally, OSHA proposes to add twenty-two test standards to the NRTL Program's List of Appropriate Test Standards.

Federal Register, Volume 83 Issue 77 (Friday, April 20, 2018)
[Federal Register Volume 83, Number 77 (Friday, April 20, 2018)]
[Notices]
[Pages 17568-17571]
From the Federal Register Online  [www.thefederalregister.org]
[FR Doc No: 2018-08256]


-----------------------------------------------------------------------

DEPARTMENT OF LABOR

Occupational Safety and Health Administration

[Docket No. OSHA-2009-0025]


Underwriters Laboratories, Inc.: Applications for Expansion of 
Recognition and Proposed Modification To Update the Nationally 
Recognized Testing Laboratory (NRTL) Program's List of Appropriate Test 
Standards

AGENCY: Occupational Safety and Health Administration (OSHA), Labor.

ACTION: Notice.

-----------------------------------------------------------------------

SUMMARY: In this notice, OSHA announces the applications of 
Underwriters Laboratories, Inc., for expansion of its scope of 
recognition as a Nationally Recognized Testing Laboratory and presents 
the Agency's preliminary finding to grant the applications. 
Additionally, OSHA proposes to add twenty-two test standards to the 
NRTL Program's List of Appropriate Test Standards.

DATES: Submit comments, information, and documents in response to this 
notice, or requests for an extension of time to make a submission, on 
or before May 7, 2018.

ADDRESSES: Submit comments by any of the following methods:
    Electronically: You may submit comments and attachments 
electronically at: http://www.regulations.gov, which is the Federal 
eRulemaking Portal. Follow the instructions online for submitting 
comments.
    Facsimile: If your comments, including attachments, are not longer 
than 10 pages, you may fax them to the OSHA Docket Office at (202) 693-
1648.
    Mail, hand delivery, express mail, messenger, or courier service: 
When using this method, you must submit a copy of your comments and 
attachments to the OSHA Docket Office, Docket No. OSHA-2009-0025, 
Occupational Safety and Health Administration, U.S. Department of 
Labor, Room N-3653, 200 Constitution Avenue NW, Washington, DC 20210. 
Deliveries (hand, express mail, messenger, and courier service) are 
accepted during the Docket Office's normal business hours, 10:00 a.m. 
to 3:00 p.m., ET.
    Instructions: All submissions must include the Agency name and OSHA 
docket number (OSHA-2009-0025) for the Information Collection Request 
(ICR). All comments, including any personal information you provide, 
are placed in the public docket without change, and may be made 
available online at http://www.regulations.gov. For further information 
on submitting comments, see the ``Public Participation'' heading in the 
section of this notice titled SUPPLEMENTARY INFORMATION.
    Docket: To read or download comments or other material in the 
docket, go to http://www.regulations.gov or the OSHA Docket Office at 
the above address. All documents in the docket (including this Federal 
Register notice) are listed in the http://www.regulations.gov index; 
however, some information (e.g., copyrighted material) is not publicly 
available to read or download through the website. All submissions, 
including copyrighted material, are available for inspection and 
copying at the OSHA Docket Office. You may also contact Kevin Robinson 
at the address below to obtain a copy of the ICR.
    Extension of comment period: Submit requests for an extension of 
the comment period on or before May 7, 2018 to the Office of Technical 
Programs and Coordination Activities, Directorate of Technical Support 
and Emergency Management, Occupational Safety and Health 
Administration, U.S. Department of Labor, 200 Constitution Avenue NW, 
Room N-3655, Washington, DC 20210, or by fax to (202) 693-1644.

FOR FURTHER INFORMATION CONTACT: Information regarding this notice is 
available from the following sources:
    Press inquiries: Contact Mr. Frank Meilinger, Director, OSHA Office 
of Communications, U.S. Department of Labor, telephone: (202) 693-1999; 
email: [email protected].

[[Page 17569]]

    General and technical information: Contact Mr. Kevin Robinson, 
Director, Office of Technical Programs and Coordination Activities, 
Directorate of Technical Support and Emergency Management, Occupational 
Safety and Health Administration, U.S. Department of Labor, phone: 
(202) 693-2110 or email: [email protected].

SUPPLEMENTARY INFORMATION: 

I. Notice of the Applications for Expansion

    The Occupational Safety and Health Administration is providing 
notice that Underwriters Laboratories, Inc., (UL) is applying for 
expansion of its current recognition as a NRTL. UL requests the 
addition of twenty-seven additional test standards to its NRTL scope of 
recognition.
    OSHA recognition of a NRTL signifies that the organization meets 
the requirements specified in 29 CFR 1910.7. Recognition is an 
acknowledgment that the organization can perform independent safety 
testing and certification of the specific products covered within its 
scope of recognition and is not a delegation or grant of government 
authority. Recognition enables employers to use products approved by 
the NRTL to meet OSHA standards that require product testing and 
certification.
    The Agency processes applications by a NRTL for initial recognition 
and for an expansion or renewal of this recognition, following 
requirements in Appendix A to 29 CFR 1910.7. This appendix requires 
that the Agency publish two notices in the Federal Register in 
processing an application. In the first notice, OSHA announces the 
application and provides its preliminary finding. In the second notice, 
the Agency provides its final decision on the application. These 
notices set forth the NRTL's scope of recognition or modifications of 
that scope. OSHA maintains an informational web page for each NRTL, 
including UL, which details the NRTL's scope of recognition. These 
pages are available from the OSHA website at http://www.osha.gov/dts/otpca/nrtl/index.html.
    Each NRTL's scope of recognition includes: (1) The type of products 
the NRTL may test, with each type specified by its applicable test 
standard; and (2) the recognized site(s) that has (have) the technical 
capability to perform the product testing and product-certification 
activities for test standards within the NRTL's scope.
    UL currently has fourteen facilities (sites) recognized by OSHA for 
product testing and certification, with its headquarters located at: 
Underwriters Laboratories, Inc. 333 Pfingsten Road, Northbrook, 
Illinois 60062. A complete list of UL sites recognized by OSHA is 
available at https://www.osha.gov/dts/otpca/nrtl/ul.html.

II. General Background on the Applications

    UL submitted an application, dated May 31, 2017, (OSHA-2009-0025-
0020), to expand its recognition to include the addition of 26 
additional test standards to UL's scope of recognition. This 
application was updated on November 1, 2017 (OSHA-2009-0025-0021) to 
include an additional standard for a total of 27 standards. OSHA staff 
performed detailed analyses of the application packets and other 
pertinent information. OSHA did not perform any on-site reviews in 
relation to these applications.
    OSHA preliminarily determined that one of the standards requested 
in UL's application, UL 2703, ``Standard for Mounting Systems, Mounting 
Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-
Plate Photovoltaic Modules and Panels,'' does not meet the requirements 
of 29 CFR 1910.7's for an appropriate test standard in OSHA's NRTL 
Program. This standard is not included on the NRTL Program's List of 
Appropriate Test Standards. The types of products covered by UL 2703 do 
not fit into any of the categories covered by OSHA's NRTL Program. 
Specifically, the standard covers mechanical mounting and support 
equipment for solar panels, i.e., mechanical products, while OSHA's 
NRTL Program addresses mainly electrical end products, as well as a few 
other product categories (e.g., fire detection and mitigation 
equipment, and Liquid Petroleum (LP) Gas equipment, and other gas-
powered equipment). The full list of the types of equipment covered by 
OSHA's NRTL Program can be viewed at https://www.osha.gov/dts/otpca/nrtl/prodcatg.html. Table 1, lists the appropriate test standards found 
in UL's application for expansion for testing and certification of 
products under the NRTL Program.

  Table 1--Proposed List of Appropriate Test Standards for Inclusion in
                     UL's NRTL Scope of Recognition
------------------------------------------------------------------------
         Test standard                     Test standard title
------------------------------------------------------------------------
*TIA 4950......................  Requirements for Battery-Powered,
                                  Portable Land Mobile Radio
                                  Applications in Class I, II, and III,
                                  Division 1, Hazardous (Classified)
                                  Locations.
*UL 25A........................  Standard for Meters for Gasoline and
                                  Gasoline/Ethanol Blends with Nominal
                                  Ethanol Concentrations up to 85
                                  Percent (E0-E85).
*UL 25B........................  Meters for Diesel Fuel, Biodiesel Fuel,
                                  Diesel/Biodiesel Blends with Nominal
                                  Biodiesel Concentrations up to 20
                                  Percent (B20), Kerosene, and Fuel Oil.
*UL 79A........................  Standard for Power-Operated Pumps for
                                  Gasoline and Gasoline/Ethanol Blends
                                  with Nominal Ethanol Concentrations up
                                  to 85 Percent (E0-E85).
*UL 79B........................  Standard for Power-Operated Pumps for
                                  Diesel Fuel, Biodiesel Fuel, Diesel/
                                  Biodiesel Blends with Nominal
                                  Biodiesel Concentrations up to 20
                                  Percent (B20), Kerosene, and Fuel Oil.
*UL 87A........................  Standard for Power-Operated Dispensing
                                  Devices for Gasoline and Gasoline/
                                  Ethanol Blends with Nominal Ethanol
                                  Concentrations up to 85 Percent (E0-
                                  E85).
*UL 87B........................  Power-Operated Dispensing Devices for
                                  Diesel Fuel, Biodiesel Fuel, Diesel/
                                  Biodiesel Blends with Nominal
                                  Biodiesel Concentrations up to 20
                                  Percent (B20), Kerosene, and Fuel Oil.
*UL 486F.......................  Bare and Covered Ferrules.
*UL 567A.......................  Standard for Emergency Breakaway
                                  Fittings, Swivel Connectors and Pipe-
                                  Connection Fittings for Gasoline and
                                  Gasoline/Ethanol Blends with Nominal
                                  Ethanol Concentrations up to 85
                                  Percent (E0-E85).
*UL 567B.......................  Standard for Emergency Breakaway
                                  Fittings, Swivel Connectors and Pipe-
                                  Connection Fittings for Diesel Fuel,
                                  Biodiesel Fuel, Diesel/Biodiesel
                                  Blends with Nominal Biodiesel
                                  Concentrations up to 20 Percent (B20),
                                  Kerosene, and Fuel Oil.
*UL 842A.......................  Standard for Valves for Gasoline and
                                  Gasoline/Ethanol Blends with Nominal
                                  Ethanol Concentrations up to 85
                                  Percent (E0-E85).
*UL 842B.......................  Standard for Valves for Diesel Fuel,
                                  Biodiesel Fuel, Diesel/Biodiesel
                                  Blends with Nominal Biodiesel
                                  Concentrations up to 20 Percent (B20),
                                  Kerosene, and Fuel Oil.
UL 962.........................  Standard for Household and Commercial
                                  Furnishings.

[[Page 17570]]

 
*UL 1973.......................  Standard for Batters for Use in Light
                                  Electric Rail (LER) Applications and
                                  Stationary Applications.
*UL 2054.......................  Standard for Household and Commercial
                                  Batteries.
*UL 2271.......................  Standard for Batteries for Use in Light
                                  Electric Vehicle (LEV) Applications.
*UL 2586A......................  Standard for Hose Nozzle Valves for
                                  Gasoline and Gasoline/Ethanol Blends
                                  with Nominal Ethanol Concentrations up
                                  to 85 Percent (E0-E85).
*UL 2586B......................  Standard for Hose Nozzle Valves for
                                  Diesel Fuel, Biodiesel Fuel, Diesel/
                                  Biodiesel Blends with Nominal
                                  Biodiesel Concentrations up to 20
                                  Percent (B20), Kerosene, and Fuel Oil.
*UL 2775.......................  Standard for Fixed Condensed Aerosol
                                  Extinguishing System Units.
UL 2594........................  Standard for Electric Vehicle Supply
                                  Equipment.
*UL 4703.......................  Standard for Photovoltaic Wire.
*UL 8753.......................  Standard for Field-Replaceable Light
                                  Emitting Diode (LED) Light Engines.
UL 60335-2-24..................  Household and Similar Electric
                                  Appliances--Safety--Part 2-24:
                                  Particular Requirements for
                                  Refrigerating Appliances, Ice-Cream
                                  Appliances and Ice-Makers.
*UL 60730-2-5..................  Automatic Electrical Controls for
                                  Household and Similar Use, Part 2-5:
                                  Particular Requirements for Automatic
                                  Electrical Burner Control Systems.
*UL 60947-5-1..................  Low-Voltage Switchgear and Controlgear--
                                  Part 5-1: Control Circuit Devices and
                                  Switching Elements--Electromechanical
                                  Control Circuit Devices.
UL 62109-1.....................  Standard for Safety of Power Converters
                                  for Use in Photovoltaic Power Systems--
                                  Part 1: General Requirements.
------------------------------------------------------------------------
* Represents the standard that OSHA proposes to add to the NRTL
  Program's List of Appropriate Test Standards.

III. Proposal To Add New Test Standard to the NRTL Program's List of 
Appropriate Test Standards

    Periodically, OSHA will propose to add new test standards to the 
NRTL List of Appropriate Test Standards following an evaluation of the 
test standard document. To qualify as an appropriate test standard, the 
Agency evaluates the document to (1) verify it represents a product 
category for which OSHA requires certification by a NRTL, (2) verify 
the document represents an end product and not a component, and (3) 
verify the document defines safety test specifications (not 
installation or operational performance specifications).
    In this notice, OSHA proposes to add twenty-two new test standards 
to the NRTL Program's List of Appropriate Test Standards. Table 2, 
lists the test standards that are new to the NRTL Program. OSHA 
preliminarily determined that these test standards are appropriate test 
standards and proposes to include them in the NRTL Program's List of 
Appropriate Test Standards. OSHA seeks public comment on this 
preliminary determination.

 Table 2--Test Standards OSHA Is Proposing To Add to the NRTL Program's
                   List of Appropriate Test Standards
------------------------------------------------------------------------
         Test standard                     Test standard title
------------------------------------------------------------------------
TIA 4950.......................  Requirements for Battery-Powered,
                                  Portable Land Mobile Radio
                                  Applications in Class I, II, and III,
                                  Division 1, Hazardous (Classified)
                                  Locations.
UL 25A.........................  Standard for Meters for Gasoline and
                                  Gasoline/Ethanol Blends with Nominal
                                  Ethanol Concentrations up to 85
                                  Percent (E0-E85).
UL 25B.........................  Meters for Diesel Fuel, Biodiesel Fuel,
                                  Diesel/Biodiesel Blends with Nominal
                                  Biodiesel Concentrations up to 20
                                  Percent (B20), Kerosene, and Fuel Oil.
UL 79A.........................  Standard for Power-Operated Pumps for
                                  Gasoline and Gasoline/Ethanol Blends
                                  with Nominal Ethanol Concentrations up
                                  to 85 Percent (E0-E85).
UL 79B.........................  Standard for Power-Operated Pumps for
                                  Diesel Fuel, Biodiesel Fuel, Diesel/
                                  Biodiesel Blends with Nominal
                                  Biodiesel Concentrations up to 20
                                  Percent (B20), Kerosene, and Fuel Oil.
UL 87A.........................  Standard for Power-Operated Dispensing
                                  Devices for Gasoline and Gasoline/
                                  Ethanol Blends with Nominal Ethanol
                                  Concentrations up to 85 Percent (E0-
                                  E85).
UL 87B.........................  Power-Operated Dispensing Devices for
                                  Diesel Fuel, Biodiesel Fuel, Diesel/
                                  Biodiesel Blends with Nominal
                                  Biodiesel Concentrations up to 20
                                  Percent (B20), Kerosene, and Fuel Oil.
UL 486F........................  Bare and Covered Ferrules.
UL 567A........................  Standard for Emergency Breakaway
                                  Fittings, Swivel Connectors and Pipe-
                                  Connection Fittings for Gasoline and
                                  Gasoline/Ethanol Blends with Nominal
                                  Ethanol Concentrations up to 85
                                  Percent (E0-E85).
UL 567B........................  Standard for Emergency Breakaway
                                  Fittings, Swivel Connectors and Pipe-
                                  Connection Fittings for Diesel Fuel,
                                  Biodiesel Fuel, Diesel/Biodiesel
                                  Blends with Nominal Biodiesel
                                  Concentrations up to 20 Percent (B20),
                                  Kerosene, and Fuel Oil.
UL 842A........................  Standard for Valves for Gasoline and
                                  Gasoline/Ethanol Blends with Nominal
                                  Ethanol Concentrations up to 85
                                  Percent (E0-E85).
UL 842B........................  Standard for Valves for Diesel Fuel,
                                  Biodiesel Fuel, Diesel/Biodiesel
                                  Blends with Nominal Biodiesel
                                  Concentrations up to 20 Percent (B20),
                                  Kerosene, and Fuel Oil.
UL 1973........................  Standard for Batters for Use in Light
                                  Electric Rail (LER) Applications and
                                  Stationary Applications.
UL 2054........................  Standard for Household and Commercial
                                  Batteries.
UL 2271........................  Standard for Batteries for Use in Light
                                  Electric Vehicle (LEV) Applications.
UL 2586A.......................  Standard for Hose Nozzle Valves for
                                  Gasoline and Gasoline/Ethanol Blends
                                  with Nominal Ethanol Concentrations up
                                  to 85 Percent (E0-E85).
UL 2586B.......................  Standard for Hose Nozzle Valves for
                                  Diesel Fuel, Biodiesel Fuel, Diesel/
                                  Biodiesel Blends with Nominal
                                  Biodiesel Concentrations up to 20
                                  Percent (B20), Kerosene, and Fuel Oil.
UL 2775........................  Standard for Fixed Condensed Aerosol
                                  Extinguishing System Units.

[[Page 17571]]

 
UL 4703........................  Standard for Photovoltaic Wire.
UL 8753........................  Standard for Field-Replaceable Light
                                  Emitting Diode (LED) Light Engines.
UL 60730-2-5...................  Automatic Electrical Controls for
                                  Household and Similar Use, Part 2-5:
                                  Particular Requirements for Automatic
                                  Electrical Burner Control Systems.
UL 60947-5-1...................  Low-Voltage Switchgear and Controlgear--
                                  Part 5-1: Control Circuit Devices and
                                  Switching Elements-Electromechanical
                                  Control Circuit Devices.
------------------------------------------------------------------------

    Because the mechanical equipment covered by UL 2703 does not fall 
within the type of equipment covered by OSHA's NRTL Program, OSHA 
preliminary determined that UL 2703 is not an appropriate test standard 
and does not propose to include it in the NRTL Program's List of 
Appropriate Test Standards. OSHA also seeks public comment on this 
preliminary determination.

IV. Preliminary Findings on the Applications

    UL submitted acceptable applications for expansion of its scope of 
recognition. OSHA's review of the application files and related 
material indicate that UL can meet the requirements prescribed by 29 
CFR 1910.7 for expanding its recognition to include the addition of the 
26 appropriate test standards for NRTL testing and certification listed 
above. This preliminary finding does not constitute an interim or 
temporary approval of UL's applications.
    OSHA welcomes public comment as to whether UL meets the 
requirements of 29 CFR 1910.7 for expansion of its recognition as a 
NRTL. Comments should consist of pertinent written documents and 
exhibits. Commenters needing more time to comment must submit a request 
in writing, stating the reasons for the request by the due date for 
comments. OSHA will limit any extension to 10 days unless the requester 
justifies a longer time period. OSHA may deny a request for an 
extension if it is not adequately justified. To obtain or review copies 
of the exhibits identified in this notice, as well as comments 
submitted to the docket, contact the Docket Office, Occupational Safety 
and Health Administration, U.S. Department of Labor, listed in 
ADDRESSES. These materials also are available online at http://www.regulations.gov under Docket No. OSHA-2009-0025.
    OSHA staff will review all comments to the docket submitted in a 
timely manner and, after addressing the issues raised by these 
comments, make a recommendation to the Assistant Secretary for 
Occupational Safety and Health on whether to grant UL's applications 
for expansion of its scope of recognition. The Assistant Secretary will 
make the final decision on granting the applications. In making this 
decision, the Assistant Secretary may undertake other proceedings 
prescribed in Appendix A to 29 CFR 1910.7.
    OSHA will publish a public notice of this final decision in the 
Federal Register.

Authority and Signature

    Loren Sweatt, Deputy Assistant Secretary of Labor for Occupational 
Safety and Health, authorized the preparation of this notice. 
Accordingly, the Agency is issuing this notice pursuant to 29 U.S.C. 
657(g)(2), Secretary of Labor's Order No. 1-2012 (77 FR 3912, Jan. 25, 
2012), and 29 CFR 1910.7.

    Signed at Washington, DC, on April 16, 2018.
Loren Sweatt,
Deputy Assistant Secretary of Labor for Occupational Safety and Health.
[FR Doc. 2018-08256 Filed 4-19-18; 8:45 am]
 BILLING CODE 4510-26-P



                                                17568                            Federal Register / Vol. 83, No. 77 / Friday, April 20, 2018 / Notices

                                                1977 sections 101 and 103(h) authorize                  other forms of information technology,                   Facsimile: If your comments,
                                                this information collection. See 30                     e.g., permitting electronic submission of             including attachments, are not longer
                                                U.S.C. 811, 813(h).                                     responses.                                            than 10 pages, you may fax them to the
                                                  This information collection is subject                  Agency: DOL–MSHA.                                   OSHA Docket Office at (202) 693–1648.
                                                to the PRA. A Federal agency generally                    Title of Collection: Permissible                       Mail, hand delivery, express mail,
                                                cannot conduct or sponsor a collection                  Equipment Testing.                                    messenger, or courier service: When
                                                of information, and the public is                         OMB Control Number: 1219–0066.                      using this method, you must submit a
                                                generally not required to respond to an                   Affected Public: Private Sector—                    copy of your comments and attachments
                                                information collection, unless it is                    businesses or other for-profits.                      to the OSHA Docket Office, Docket No.
                                                approved by the OMB under the PRA                         Total Estimated Number of                           OSHA–2009–0025, Occupational Safety
                                                and displays a currently valid OMB                      Respondents: 139.                                     and Health Administration, U.S.
                                                Control Number. In addition,                              Total Estimated Number of                           Department of Labor, Room N–3653,
                                                notwithstanding any other provisions of                 Responses: 296.                                       200 Constitution Avenue NW,
                                                law, no person shall generally be subject                 Total Estimated Annual Time Burden:                 Washington, DC 20210. Deliveries
                                                to penalty for failing to comply with a                 3,198 hours.                                          (hand, express mail, messenger, and
                                                collection of information that does not                   Total Estimated Annual Other Costs                  courier service) are accepted during the
                                                display a valid Control Number. See 5                   Burden: $1,732,147.                                   Docket Office’s normal business hours,
                                                CFR 1320.5(a) and 1320.6. The DOL                         Authority: 44 U.S.C. 3507(a)(1)(D).                 10:00 a.m. to 3:00 p.m., ET.
                                                obtains OMB approval for this                                                                                    Instructions: All submissions must
                                                                                                          Dated: April 13, 2018.
                                                information collection under Control                                                                          include the Agency name and OSHA
                                                Number 1219–0066.                                       Michel Smyth,                                         docket number (OSHA–2009–0025) for
                                                  OMB authorization for an ICR cannot                   Departmental Clearance Officer.                       the Information Collection Request
                                                be for more than three (3) years without                [FR Doc. 2018–08275 Filed 4–19–18; 8:45 am]           (ICR). All comments, including any
                                                renewal, and the current approval for                   BILLING CODE 4510–43–P                                personal information you provide, are
                                                this collection is scheduled to expire on                                                                     placed in the public docket without
                                                April 30, 2018. The DOL seeks to extend                                                                       change, and may be made available
                                                PRA authorization for this information                  DEPARTMENT OF LABOR                                   online at http://www.regulations.gov.
                                                collection for three (3) more years,                                                                          For further information on submitting
                                                without any change to existing                          Occupational Safety and Health                        comments, see the ‘‘Public
                                                requirements. The DOL notes that                        Administration                                        Participation’’ heading in the section of
                                                existing information collection                         [Docket No. OSHA–2009–0025]                           this notice titled SUPPLEMENTARY
                                                requirements submitted to the OMB                                                                             INFORMATION.
                                                receive a month-to-month extension                      Underwriters Laboratories, Inc.:                         Docket: To read or download
                                                while they undergo review. For                          Applications for Expansion of                         comments or other material in the
                                                additional substantive information                      Recognition and Proposed                              docket, go to http://www.regulations.gov
                                                about this ICR, see the related notice                  Modification To Update the Nationally                 or the OSHA Docket Office at the above
                                                published in the Federal Register on                    Recognized Testing Laboratory (NRTL)                  address. All documents in the docket
                                                November 17, 2017 (82 FR 54419).                        Program’s List of Appropriate Test                    (including this Federal Register notice)
                                                  Interested parties are encouraged to                  Standards                                             are listed in the http://
                                                send comments to the OMB, Office of                                                                           www.regulations.gov index; however,
                                                Information and Regulatory Affairs at                   AGENCY: Occupational Safety and Health                some information (e.g., copyrighted
                                                the address shown in the ADDRESSES                      Administration (OSHA), Labor.                         material) is not publicly available to
                                                section within thirty (30) days of                      ACTION: Notice.                                       read or download through the website.
                                                publication of this notice in the Federal                                                                     All submissions, including copyrighted
                                                                                                        SUMMARY:   In this notice, OSHA                       material, are available for inspection
                                                Register. In order to help ensure                       announces the applications of
                                                appropriate consideration, comments                                                                           and copying at the OSHA Docket Office.
                                                                                                        Underwriters Laboratories, Inc., for                  You may also contact Kevin Robinson at
                                                should mention OMB Control Number                       expansion of its scope of recognition as
                                                1219–0066. The OMB is particularly                                                                            the address below to obtain a copy of
                                                                                                        a Nationally Recognized Testing                       the ICR.
                                                interested in comments that:                            Laboratory and presents the Agency’s
                                                  • Evaluate whether the proposed                                                                                Extension of comment period: Submit
                                                                                                        preliminary finding to grant the                      requests for an extension of the
                                                collection of information is necessary
                                                                                                        applications. Additionally, OSHA                      comment period on or before May 7,
                                                for the proper performance of the
                                                                                                        proposes to add twenty-two test                       2018 to the Office of Technical
                                                functions of the agency, including
                                                                                                        standards to the NRTL Program’s List of               Programs and Coordination Activities,
                                                whether the information will have
                                                                                                        Appropriate Test Standards.                           Directorate of Technical Support and
                                                practical utility;
                                                  • Evaluate the accuracy of the                        DATES: Submit comments, information,                  Emergency Management, Occupational
                                                agency’s estimate of the burden of the                  and documents in response to this                     Safety and Health Administration, U.S.
                                                proposed collection of information,                     notice, or requests for an extension of               Department of Labor, 200 Constitution
                                                including the validity of the                           time to make a submission, on or before               Avenue NW, Room N–3655,
                                                methodology and assumptions used;                       May 7, 2018.                                          Washington, DC 20210, or by fax to
                                                  • Enhance the quality, utility, and                   ADDRESSES: Submit comments by any of                  (202) 693–1644.
sradovich on DSK3GMQ082PROD with NOTICES




                                                clarity of the information to be                        the following methods:                                FOR FURTHER INFORMATION CONTACT:
                                                collected; and                                            Electronically: You may submit                      Information regarding this notice is
                                                  • Minimize the burden of the                          comments and attachments                              available from the following sources:
                                                collection of information on those who                  electronically at: http://                               Press inquiries: Contact Mr. Frank
                                                are to respond, including through the                   www.regulations.gov, which is the                     Meilinger, Director, OSHA Office of
                                                use of appropriate automated,                           Federal eRulemaking Portal. Follow the                Communications, U.S. Department of
                                                electronic, mechanical, or other                        instructions online for submitting                    Labor, telephone: (202) 693–1999;
                                                technological collection techniques or                  comments.                                             email: meilinger.francis2@dol.gov.


                                           VerDate Sep<11>2014   17:44 Apr 19, 2018   Jkt 244001   PO 00000   Frm 00049   Fmt 4703   Sfmt 4703   E:\FR\FM\20APN1.SGM   20APN1


                                                                                   Federal Register / Vol. 83, No. 77 / Friday, April 20, 2018 / Notices                                          17569

                                                  General and technical information:                      Register in processing an application. In             2009–0025–0021) to include an
                                                Contact Mr. Kevin Robinson, Director,                     the first notice, OSHA announces the                  additional standard for a total of 27
                                                Office of Technical Programs and                          application and provides its preliminary              standards. OSHA staff performed
                                                Coordination Activities, Directorate of                   finding. In the second notice, the                    detailed analyses of the application
                                                Technical Support and Emergency                           Agency provides its final decision on                 packets and other pertinent information.
                                                Management, Occupational Safety and                       the application. These notices set forth              OSHA did not perform any on-site
                                                Health Administration, U.S. Department                    the NRTL’s scope of recognition or                    reviews in relation to these applications.
                                                of Labor, phone: (202) 693–2110 or                        modifications of that scope. OSHA                        OSHA preliminarily determined that
                                                email: robinson.kevin@dol.gov.                            maintains an informational web page for               one of the standards requested in UL’s
                                                SUPPLEMENTARY INFORMATION:                                each NRTL, including UL, which details                application, UL 2703, ‘‘Standard for
                                                                                                          the NRTL’s scope of recognition. These                Mounting Systems, Mounting Devices,
                                                I. Notice of the Applications for
                                                                                                          pages are available from the OSHA                     Clamping/Retention Devices, and
                                                Expansion
                                                                                                          website at http://www.osha.gov/dts/                   Ground Lugs for Use with Flat-Plate
                                                   The Occupational Safety and Health                     otpca/nrtl/index.html.
                                                Administration is providing notice that                                                                         Photovoltaic Modules and Panels,’’ does
                                                                                                             Each NRTL’s scope of recognition
                                                Underwriters Laboratories, Inc., (UL) is                                                                        not meet the requirements of 29 CFR
                                                                                                          includes: (1) The type of products the
                                                applying for expansion of its current                                                                           1910.7’s for an appropriate test standard
                                                                                                          NRTL may test, with each type specified
                                                recognition as a NRTL. UL requests the                                                                          in OSHA’s NRTL Program. This
                                                                                                          by its applicable test standard; and (2)
                                                addition of twenty-seven additional test                                                                        standard is not included on the NRTL
                                                                                                          the recognized site(s) that has (have) the
                                                standards to its NRTL scope of                            technical capability to perform the                   Program’s List of Appropriate Test
                                                recognition.                                              product testing and product-                          Standards. The types of products
                                                   OSHA recognition of a NRTL signifies                   certification activities for test standards           covered by UL 2703 do not fit into any
                                                that the organization meets the                           within the NRTL’s scope.                              of the categories covered by OSHA’s
                                                requirements specified in 29 CFR                             UL currently has fourteen facilities               NRTL Program. Specifically, the
                                                1910.7. Recognition is an                                 (sites) recognized by OSHA for product                standard covers mechanical mounting
                                                acknowledgment that the organization                      testing and certification, with its                   and support equipment for solar panels,
                                                can perform independent safety testing                    headquarters located at: Underwriters                 i.e., mechanical products, while OSHA’s
                                                and certification of the specific products                Laboratories, Inc. 333 Pfingsten Road,                NRTL Program addresses mainly
                                                covered within its scope of recognition                   Northbrook, Illinois 60062. A complete                electrical end products, as well as a few
                                                and is not a delegation or grant of                       list of UL sites recognized by OSHA is                other product categories (e.g., fire
                                                government authority. Recognition                         available at https://www.osha.gov/dts/                detection and mitigation equipment,
                                                enables employers to use products                         otpca/nrtl/ul.html.                                   and Liquid Petroleum (LP) Gas
                                                approved by the NRTL to meet OSHA                                                                               equipment, and other gas-powered
                                                standards that require product testing                    II. General Background on the                         equipment). The full list of the types of
                                                and certification.                                        Applications                                          equipment covered by OSHA’s NRTL
                                                   The Agency processes applications by                      UL submitted an application, dated                 Program can be viewed at https://
                                                a NRTL for initial recognition and for an                 May 31, 2017, (OSHA–2009–0025–                        www.osha.gov/dts/otpca/nrtl/
                                                expansion or renewal of this                              0020), to expand its recognition to                   prodcatg.html. Table 1, lists the
                                                recognition, following requirements in                    include the addition of 26 additional                 appropriate test standards found in UL’s
                                                Appendix A to 29 CFR 1910.7. This                         test standards to UL’s scope of                       application for expansion for testing and
                                                appendix requires that the Agency                         recognition. This application was                     certification of products under the
                                                publish two notices in the Federal                        updated on November 1, 2017 (OSHA–                    NRTL Program.

                                                  TABLE 1—PROPOSED LIST OF APPROPRIATE TEST STANDARDS FOR INCLUSION IN UL’S NRTL SCOPE OF RECOGNITION
                                                   Test standard                                                                       Test standard title

                                                *TIA 4950 .............    Requirements for Battery-Powered, Portable Land Mobile Radio Applications in Class I, II, and III, Division 1, Hazardous
                                                                             (Classified) Locations.
                                                *UL 25A ................   Standard for Meters for Gasoline and Gasoline/Ethanol Blends with Nominal Ethanol Concentrations up to 85 Percent (E0–
                                                                             E85).
                                                *UL 25B ................   Meters for Diesel Fuel, Biodiesel Fuel, Diesel/Biodiesel Blends with Nominal Biodiesel Concentrations up to 20 Percent
                                                                             (B20), Kerosene, and Fuel Oil.
                                                *UL 79A ................   Standard for Power-Operated Pumps for Gasoline and Gasoline/Ethanol Blends with Nominal Ethanol Concentrations up to
                                                                             85 Percent (E0–E85).
                                                *UL 79B ................   Standard for Power-Operated Pumps for Diesel Fuel, Biodiesel Fuel, Diesel/Biodiesel Blends with Nominal Biodiesel Con-
                                                                             centrations up to 20 Percent (B20), Kerosene, and Fuel Oil.
                                                *UL 87A ................   Standard for Power-Operated Dispensing Devices for Gasoline and Gasoline/Ethanol Blends with Nominal Ethanol Con-
                                                                             centrations up to 85 Percent (E0–E85).
                                                *UL 87B ................   Power-Operated Dispensing Devices for Diesel Fuel, Biodiesel Fuel, Diesel/Biodiesel Blends with Nominal Biodiesel Con-
                                                                             centrations up to 20 Percent (B20), Kerosene, and Fuel Oil.
                                                *UL 486F ..............    Bare and Covered Ferrules.
                                                *UL 567A ..............    Standard for Emergency Breakaway Fittings, Swivel Connectors and Pipe-Connection Fittings for Gasoline and Gasoline/
sradovich on DSK3GMQ082PROD with NOTICES




                                                                             Ethanol Blends with Nominal Ethanol Concentrations up to 85 Percent (E0–E85).
                                                *UL 567B ..............    Standard for Emergency Breakaway Fittings, Swivel Connectors and Pipe-Connection Fittings for Diesel Fuel, Biodiesel
                                                                             Fuel, Diesel/Biodiesel Blends with Nominal Biodiesel Concentrations up to 20 Percent (B20), Kerosene, and Fuel Oil.
                                                *UL 842A ..............    Standard for Valves for Gasoline and Gasoline/Ethanol Blends with Nominal Ethanol Concentrations up to 85 Percent (E0–
                                                                             E85).
                                                *UL 842B ..............    Standard for Valves for Diesel Fuel, Biodiesel Fuel, Diesel/Biodiesel Blends with Nominal Biodiesel Concentrations up to 20
                                                                             Percent (B20), Kerosene, and Fuel Oil.
                                                UL 962 .................   Standard for Household and Commercial Furnishings.



                                           VerDate Sep<11>2014     17:44 Apr 19, 2018   Jkt 244001   PO 00000   Frm 00050   Fmt 4703   Sfmt 4703   E:\FR\FM\20APN1.SGM   20APN1


                                                17570                               Federal Register / Vol. 83, No. 77 / Friday, April 20, 2018 / Notices

                                                 TABLE 1—PROPOSED LIST OF APPROPRIATE TEST STANDARDS FOR INCLUSION IN UL’S NRTL SCOPE OF RECOGNITION—
                                                                                              Continued
                                                   Test standard                                                                        Test standard title

                                                *UL   1973 ..............   Standard for Batters for Use in Light Electric Rail (LER) Applications and Stationary Applications.
                                                *UL   2054 ..............   Standard for Household and Commercial Batteries.
                                                *UL   2271 ..............   Standard for Batteries for Use in Light Electric Vehicle (LEV) Applications.
                                                *UL   2586A ............    Standard for Hose Nozzle Valves for Gasoline and Gasoline/Ethanol Blends with Nominal Ethanol Concentrations up to 85
                                                                              Percent (E0–E85).
                                                *UL 2586B ............      Standard for Hose Nozzle Valves for Diesel Fuel, Biodiesel Fuel, Diesel/Biodiesel Blends with Nominal Biodiesel Con-
                                                                              centrations up to 20 Percent (B20), Kerosene, and Fuel Oil.
                                                *UL 2775 ..............     Standard for Fixed Condensed Aerosol Extinguishing System Units.
                                                UL 2594 ...............     Standard for Electric Vehicle Supply Equipment.
                                                *UL 4703 ..............     Standard for Photovoltaic Wire.
                                                *UL 8753 ..............     Standard for Field-Replaceable Light Emitting Diode (LED) Light Engines.
                                                UL 60335–2–24 ...           Household and Similar Electric Appliances—Safety—Part 2–24: Particular Requirements for Refrigerating Appliances, Ice-
                                                                              Cream Appliances and Ice-Makers.
                                                *UL 60730–2–5 ....          Automatic Electrical Controls for Household and Similar Use, Part 2–5: Particular Requirements for Automatic Electrical
                                                                              Burner Control Systems.
                                                *UL 60947–5–1 ....          Low-Voltage Switchgear and Controlgear—Part 5–1: Control Circuit Devices and Switching Elements—Electromechanical
                                                                              Control Circuit Devices.
                                                UL 62109–1 .........        Standard for Safety of Power Converters for Use in Photovoltaic Power Systems—Part 1: General Requirements.
                                                   * Represents the standard that OSHA proposes to add to the NRTL Program’s List of Appropriate Test Standards.


                                                III. Proposal To Add New Test                              document to (1) verify it represents a                NRTL Program’s List of Appropriate
                                                Standard to the NRTL Program’s List of                     product category for which OSHA                       Test Standards. Table 2, lists the test
                                                Appropriate Test Standards                                 requires certification by a NRTL, (2)                 standards that are new to the NRTL
                                                                                                           verify the document represents an end                 Program. OSHA preliminarily
                                                  Periodically, OSHA will propose to                       product and not a component, and (3)                  determined that these test standards are
                                                add new test standards to the NRTL List                    verify the document defines safety test               appropriate test standards and proposes
                                                of Appropriate Test Standards following                    specifications (not installation or                   to include them in the NRTL Program’s
                                                an evaluation of the test standard                         operational performance specifications).              List of Appropriate Test Standards.
                                                document. To qualify as an appropriate                       In this notice, OSHA proposes to add                OSHA seeks public comment on this
                                                test standard, the Agency evaluates the                    twenty-two new test standards to the                  preliminary determination.
                                                      TABLE 2—TEST STANDARDS OSHA IS PROPOSING TO ADD TO THE NRTL PROGRAM’S LIST OF APPROPRIATE TEST
                                                                                               STANDARDS
                                                   Test standard                                                                        Test standard title

                                                TIA 4950 ..............     Requirements for Battery-Powered, Portable Land Mobile Radio Applications in Class I, II, and III, Division 1, Hazardous
                                                                              (Classified) Locations.
                                                UL 25A .................    Standard for Meters for Gasoline and Gasoline/Ethanol Blends with Nominal Ethanol Concentrations up to 85 Percent (E0–
                                                                              E85).
                                                UL 25B .................    Meters for Diesel Fuel, Biodiesel Fuel, Diesel/Biodiesel Blends with Nominal Biodiesel Concentrations up to 20 Percent
                                                                              (B20), Kerosene, and Fuel Oil.
                                                UL 79A .................    Standard for Power-Operated Pumps for Gasoline and Gasoline/Ethanol Blends with Nominal Ethanol Concentrations up to
                                                                              85 Percent (E0–E85).
                                                UL 79B .................    Standard for Power-Operated Pumps for Diesel Fuel, Biodiesel Fuel, Diesel/Biodiesel Blends with Nominal Biodiesel Con-
                                                                              centrations up to 20 Percent (B20), Kerosene, and Fuel Oil.
                                                UL 87A .................    Standard for Power-Operated Dispensing Devices for Gasoline and Gasoline/Ethanol Blends with Nominal Ethanol Con-
                                                                              centrations up to 85 Percent (E0–E85).
                                                UL 87B .................    Power-Operated Dispensing Devices for Diesel Fuel, Biodiesel Fuel, Diesel/Biodiesel Blends with Nominal Biodiesel Con-
                                                                              centrations up to 20 Percent (B20), Kerosene, and Fuel Oil.
                                                UL 486F ...............     Bare and Covered Ferrules.
                                                UL 567A ...............     Standard for Emergency Breakaway Fittings, Swivel Connectors and Pipe-Connection Fittings for Gasoline and Gasoline/
                                                                              Ethanol Blends with Nominal Ethanol Concentrations up to 85 Percent (E0–E85).
                                                UL 567B ...............     Standard for Emergency Breakaway Fittings, Swivel Connectors and Pipe-Connection Fittings for Diesel Fuel, Biodiesel
                                                                              Fuel, Diesel/Biodiesel Blends with Nominal Biodiesel Concentrations up to 20 Percent (B20), Kerosene, and Fuel Oil.
                                                UL 842A ...............     Standard for Valves for Gasoline and Gasoline/Ethanol Blends with Nominal Ethanol Concentrations up to 85 Percent (E0–
                                                                              E85).
                                                UL 842B ...............     Standard for Valves for Diesel Fuel, Biodiesel Fuel, Diesel/Biodiesel Blends with Nominal Biodiesel Concentrations up to 20
                                                                              Percent (B20), Kerosene, and Fuel Oil.
sradovich on DSK3GMQ082PROD with NOTICES




                                                UL   1973 ...............   Standard for Batters for Use in Light Electric Rail (LER) Applications and Stationary Applications.
                                                UL   2054 ...............   Standard for Household and Commercial Batteries.
                                                UL   2271 ...............   Standard for Batteries for Use in Light Electric Vehicle (LEV) Applications.
                                                UL   2586A .............    Standard for Hose Nozzle Valves for Gasoline and Gasoline/Ethanol Blends with Nominal Ethanol Concentrations up to 85
                                                                              Percent (E0–E85).
                                                UL 2586B .............      Standard for Hose Nozzle Valves for Diesel Fuel, Biodiesel Fuel, Diesel/Biodiesel Blends with Nominal Biodiesel Con-
                                                                              centrations up to 20 Percent (B20), Kerosene, and Fuel Oil.
                                                UL 2775 ...............     Standard for Fixed Condensed Aerosol Extinguishing System Units.



                                           VerDate Sep<11>2014      17:44 Apr 19, 2018   Jkt 244001   PO 00000   Frm 00051   Fmt 4703   Sfmt 4703   E:\FR\FM\20APN1.SGM   20APN1


                                                                                  Federal Register / Vol. 83, No. 77 / Friday, April 20, 2018 / Notices                                         17571

                                                    TABLE 2—TEST STANDARDS OSHA IS PROPOSING TO ADD TO THE NRTL PROGRAM’S LIST OF APPROPRIATE TEST
                                                                                       STANDARDS—Continued
                                                   Test standard                                                                      Test standard title

                                                UL 4703 ...............   Standard for Photovoltaic Wire.
                                                UL 8753 ...............   Standard for Field-Replaceable Light Emitting Diode (LED) Light Engines.
                                                UL 60730–2–5 .....        Automatic Electrical Controls for Household and Similar Use, Part 2–5: Particular Requirements for Automatic Electrical
                                                                            Burner Control Systems.
                                                UL 60947–5–1 .....        Low-Voltage Switchgear and Controlgear—Part 5–1: Control Circuit Devices and Switching Elements–Electromechanical
                                                                            Control Circuit Devices.



                                                  Because the mechanical equipment                       Health on whether to grant UL’s                       FOR FURTHER INFORMATION CONTACT:
                                                covered by UL 2703 does not fall within                  applications for expansion of its scope               Information regarding this notice is
                                                the type of equipment covered by                         of recognition. The Assistant Secretary               available from the following sources:
                                                OSHA’s NRTL Program, OSHA                                will make the final decision on granting                Press inquiries: Contact Mr. Frank
                                                preliminary determined that UL 2703 is                   the applications. In making this                      Meilinger, Director, OSHA Office of
                                                not an appropriate test standard and                     decision, the Assistant Secretary may                 Communications, U.S. Department of
                                                does not propose to include it in the                    undertake other proceedings prescribed                Labor; telephone: (202) 693–1999;
                                                NRTL Program’s List of Appropriate                       in Appendix A to 29 CFR 1910.7.                       email: meilinger.francis2@dol.gov.
                                                Test Standards. OSHA also seeks public                     OSHA will publish a public notice of                  General and technical information:
                                                comment on this preliminary                              this final decision in the Federal                    Contact Mr. Kevin Robinson, Director,
                                                determination.                                           Register.                                             Office of Technical Programs and
                                                                                                                                                               Coordination Activities, Directorate of
                                                IV. Preliminary Findings on the                          Authority and Signature                               Technical Support and Emergency
                                                Applications                                                                                                   Management, Occupational Safety and
                                                                                                           Loren Sweatt, Deputy Assistant
                                                  UL submitted acceptable applications                   Secretary of Labor for Occupational                   Health Administration; telephone: (202)
                                                for expansion of its scope of recognition.               Safety and Health, authorized the                     693–2110; email: robinson.kevin@
                                                OSHA’s review of the application files                   preparation of this notice. Accordingly,              dol.gov. OSHA’s web page includes
                                                and related material indicate that UL                    the Agency is issuing this notice                     information about the NRTL Program
                                                can meet the requirements prescribed by                  pursuant to 29 U.S.C. 657(g)(2),                      (see http://www.osha.gov/dts/otpca/
                                                29 CFR 1910.7 for expanding its                          Secretary of Labor’s Order No. 1–2012                 nrtl/index.html).
                                                recognition to include the addition of                   (77 FR 3912, Jan. 25, 2012), and 29 CFR               SUPPLEMENTARY INFORMATION:
                                                the 26 appropriate test standards for                    1910.7.
                                                NRTL testing and certification listed                                                                          I. Background
                                                above. This preliminary finding does                       Signed at Washington, DC, on April 16,                 The NRTL Program recognizes
                                                not constitute an interim or temporary                   2018.
                                                                                                                                                               organizations that provide product
                                                approval of UL’s applications.                           Loren Sweatt,                                         safety testing and certification services
                                                  OSHA welcomes public comment as                        Deputy Assistant Secretary of Labor for               to manufacturers. These organizations
                                                to whether UL meets the requirements                     Occupational Safety and Health.                       perform testing and certification, for
                                                of 29 CFR 1910.7 for expansion of its                    [FR Doc. 2018–08256 Filed 4–19–18; 8:45 am]           purposes of the Program, to U.S.
                                                recognition as a NRTL. Comments                          BILLING CODE 4510–26–P                                consensus-based product safety test
                                                should consist of pertinent written                                                                            standards. The products covered by the
                                                documents and exhibits. Commenters                                                                             Program consist of those items for
                                                needing more time to comment must                        DEPARTMENT OF LABOR                                   which OSHA safety standards require
                                                submit a request in writing, stating the                                                                       ‘‘certification’’ by a NRTL. The
                                                reasons for the request by the due date                  Occupational Safety and Health
                                                                                                                                                               requirements affect electrical products
                                                for comments. OSHA will limit any                        Administration
                                                                                                                                                               and 38 other types of products. OSHA
                                                extension to 10 days unless the                                                                                does not develop or issue these test
                                                requester justifies a longer time period.                [Docket No. OSHA–2013–0012]                           standards, but generally relies on
                                                OSHA may deny a request for an                                                                                 standards development organizations
                                                extension if it is not adequately                        Modification to the List of Appropriate               (SDOs) which develop and maintain the
                                                justified. To obtain or review copies of                 NRTL Program Test Standards and the                   standards using a method that provides
                                                the exhibits identified in this notice, as               Scopes of Recognition of Several                      input and consideration of views of
                                                well as comments submitted to the                        NRTLs                                                 industry groups, experts, users,
                                                docket, contact the Docket Office,                       AGENCY: Occupational Safety and Health                consumers, governmental authorities,
                                                Occupational Safety and Health                           Administration (OSHA), Labor.                         and others having broad experience in
                                                Administration, U.S. Department of                                                                             the safety field involved.
                                                Labor, listed in ADDRESSES. These                        ACTION: Notice of final decisions.
                                                materials also are available online at                                                                         Removal of Test Standards From the
                                                                                                         SUMMARY:   In this notice, OSHA                       NRTL List of Appropriate Test
sradovich on DSK3GMQ082PROD with NOTICES




                                                http://www.regulations.gov under
                                                Docket No. OSHA–2009–0025.                               announces its final decision to: (1)                  Standards
                                                  OSHA staff will review all comments                    Delete a test standard from the NRTL                    OSHA may propose to remove a test
                                                to the docket submitted in a timely                      Program’s list of appropriate test                    standard from the NRTL list of
                                                manner and, after addressing the issues                  standards; and (2) update the scopes of               appropriate test standards based on an
                                                raised by these comments, make a                         recognition of several NRTLs.                         internal review in which Program staff
                                                recommendation to the Assistant                          DATES: OSHA’s final decisions are                     review the NRTL list of appropriate test
                                                Secretary for Occupational Safety and                    effective on April 20, 2018.                          standards to determine if the test


                                           VerDate Sep<11>2014    17:44 Apr 19, 2018   Jkt 244001   PO 00000   Frm 00052   Fmt 4703   Sfmt 4703   E:\FR\FM\20APN1.SGM   20APN1



Document Created: 2018-04-20 00:02:41
Document Modified: 2018-04-20 00:02:41
CategoryRegulatory Information
CollectionFederal Register
sudoc ClassAE 2.7:
GS 4.107:
AE 2.106:
PublisherOffice of the Federal Register, National Archives and Records Administration
SectionNotices
ActionNotice.
DatesSubmit comments, information, and documents in response to this notice, or requests for an extension of time to make a submission, on or before May 7, 2018.
ContactInformation regarding this notice is available from the following sources:
FR Citation83 FR 17568 

2025 Federal Register | Disclaimer | Privacy Policy