81 FR 49690 - Virgil C. Summer Nuclear Station, Units 2 and 3; South Carolina Electric & Gas Company; Main Control Room Emergency Habitability System Design Changes

NUCLEAR REGULATORY COMMISSION

Federal Register Volume 81, Issue 145 (July 28, 2016)

Page Range49690-49691
FR Document2016-17918

The U.S. Nuclear Regulatory Commission (NRC) is granting an exemption to allow a departure from the certification information of Tier 1 of the generic design control document (DCD) and is issuing License Amendment No. 49 to Combined Licenses (COLs), NPF-93 and NPF- 94. The COLs were issued to South Carolina Electric & Gas (SCE&G) (the licensee); for construction and operation of the Virgil C. Summer Nuclear Station (VCSNS) Units 2 and 3, located in Fairfield County, South Carolina. The granting of the exemption allows the changes to Tier 1 information asked for in the amendment. Because the acceptability of the exemption was determined in part by the acceptability of the amendment, the exemption and amendment are being issued concurrently.

Federal Register, Volume 81 Issue 145 (Thursday, July 28, 2016)
[Federal Register Volume 81, Number 145 (Thursday, July 28, 2016)]
[Notices]
[Pages 49690-49691]
From the Federal Register Online  [www.thefederalregister.org]
[FR Doc No: 2016-17918]


=======================================================================
-----------------------------------------------------------------------

NUCLEAR REGULATORY COMMISSION

[Docket Nos. 52-027 and 52-028; NRC-2008-0441]


Virgil C. Summer Nuclear Station, Units 2 and 3; South Carolina 
Electric & Gas Company; Main Control Room Emergency Habitability System 
Design Changes

AGENCY: Nuclear Regulatory Commission.

ACTION: Exemption and combined license amendment; issuance.

-----------------------------------------------------------------------

SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) is granting an 
exemption to allow a departure from the certification information of 
Tier 1 of the generic design control document (DCD) and is issuing 
License Amendment No. 49 to Combined Licenses (COLs), NPF-93 and NPF-
94. The COLs were issued to South Carolina Electric & Gas (SCE&G) (the 
licensee); for construction and operation of the Virgil C. Summer 
Nuclear Station (VCSNS) Units 2 and 3, located in Fairfield County, 
South Carolina. The granting of the exemption allows the changes to 
Tier 1 information asked for in the amendment. Because the 
acceptability of the exemption was determined in part by the 
acceptability of the amendment, the exemption and amendment are being 
issued concurrently.

DATES: The exemption and combined license amendment referenced in this 
document are available on July 28, 2016.

ADDRESSES: Please refer to Docket ID NRC-2008-0441 when contacting the 
NRC about the availability of information regarding this document. You 
may obtain publicly-available information related to this document 
using any of the following methods:
     Federal Rulemaking Web site: Go to http://www.regulations.gov and search for Docket ID NRC-2008-0441. Address 
questions about NRC dockets to Carol Gallagher; telephone: 301-415-
3463; email: [email protected]. For technical questions, contact 
the individual listed in the FOR FURTHER INFORMATION CONTACT section of 
this document.
     NRC's Agencywide Documents Access and Management System 
(ADAMS): You may obtain publicly available documents online in the 
ADAMS Public Documents collection at http://www.nrc.gov/reading-rm/adams.html. To begin the search, select ``ADAMS Public Documents'' and 
then select ``Begin Web-based ADAMS Search.'' For problems with ADAMS, 
please contact the NRC's Public Document Room (PDR) reference staff at 
1-800-397-4209, 301-415-4737, or by email to [email protected]. The 
ADAMS accession number for each document referenced in this document 
(if that document is available in ADAMS) is provided the first time 
that a document is referenced. The request for the amendment and 
exemption was submitted by letter dated June 30, 2015 (ADAMS Accession 
No. ML15181A470)
     NRC's PDR: You may examine and purchase copies of public 
documents at the NRC's PDR, Room O1-F21, One White Flint North, 11555 
Rockville Pike, Rockville, Maryland 20852.

FOR FURTHER INFORMATION CONTACT: Paul Kallan, Office of New Reactors, 
U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001; 
telephone: 301-415-2809; email: [email protected].

SUPPLEMENTARY INFORMATION:

I. Introduction

    The NRC is granting an exemption from paragraph B of section III, 
``Scope and Contents,'' of Appendix D, ``Design Certification Rule for 
the AP1000,'' to part 52 of title 10 of the Code of Federal Regulations 
(10 CFR) and issuing License Amendment No. 49 to COLs, NPF-93 and NPF-
94, to the licensee. The exemption is required by paragraph A.4 of 
Section VIII, ``Processes for Changes and Departures,'' Appendix D, to 
10 CFR part 52 to allow the licensee to depart from Tier 1 information. 
With the requested amendment, the licensee sought proposed changes that 
would revise ASME safety classification and transition location, 
equipment orientation and removal, and identification of the number of

[[Page 49691]]

emergency air storage tanks. The proposed changes to the Main Control 
Room Emergency Habitability System (VES) revises Tier 1 and 
corresponding information in COL Appendix C, Figure 2.2.5-1. It also 
revises Tier 2 information in the Updated Final Safety Analysis Report.
    Part of the justification for granting the exemption was provided 
by the review of the amendment. Because the exemption is necessary in 
order to issue the requested license amendment, the NRC granted the 
exemption and issued the amendment concurrently, rather than in 
sequence. This included issuing a combined safety evaluation containing 
the NRC staff's review of both the exemption request and the license 
amendment. The exemption met all applicable regulatory criteria set 
forth in 10 CFR 50.12, 10 CFR 52.7, and Section VIII.A.4 of Appendix D 
to 10 CFR part 52. The license amendment was found to be acceptable as 
well. The combined safety evaluation is available in ADAMS under 
Accession No. ML16095A202.
    Identical exemption documents (except for referenced unit numbers 
and license numbers) were issued to the licensee for VCSNS Units 2 and 
3 (COLs NPF-93 and NPF-94). The exemption documents for VCSNS Units 2 
and 3 can be found in ADAMS under Accession Nos. ML16095A141 and 
ML16095A144, respectively. The exemption is reproduced (with the 
exception of abbreviated titles and additional citations) in Section II 
of this document. The amendment documents for COLs NPF-93 and NPF-94 
are available in ADAMS under Accession Nos. ML16095A132 and 
ML16095A137, respectively. A summary of the amendment documents is 
provided in Section III of this document.

II. Exemption

    Following is the exemption document issued to VCSNS Units 2 and 
Unit 3. It makes reference to the combined safety evaluation that 
provides the reasoning for the findings made by the NRC (and listed 
under Item 1) in order to grant the exemption:
    1. In a letter dated June 30, 2015, the licensee requested from the 
Commission an exemption from the provisions of 10 CFR part 52, appendix 
D, section III.B, as part of license amendment request 15-03, ``Main 
Control Room Emergency Habitability System (VES) Design Changes (LAR 
15-03).''
    For the reasons set forth in Section 3.1, ``Evaluation of 
Exemption,'' of the NRC staff's Safety Evaluation, which can be found 
in ADAMS under Accession No. ML16095A202, the Commission finds that:
    A. The exemption is authorized by law;
    B. the exemption presents no undue risk to public health and 
safety;
    C. the exemption is consistent with the common defense and 
security;
    D. special circumstances are present in that the application of the 
rule in this circumstance is not necessary to serve the underlying 
purpose of the rule;
    E. the special circumstances outweigh any decrease in safety that 
may result from the reduction in standardization caused by the 
exemption; and
    F. the exemption will not result in a significant decrease in the 
level of safety otherwise provided by the design.
    2. Accordingly, the licensee is granted an exemption from the 
certified DCD Tier 1, as described in the licensee's request dated June 
30, 2015. This exemption is related to, and necessary for the granting 
of License Amendment No. 49, which is being issued concurrently with 
this exemption.
    3. As explained in Section 5.0, ``Environmental Consideration,'' of 
the NRC staff's Safety Evaluation (ADAMS Accession No. ML16095A202), 
this exemption meets the eligibility criteria for categorical exclusion 
set forth in 10 CFR 51.22(c)(9). Therefore, pursuant to 10 CFR 
51.22(b), no environmental impact statement or environmental assessment 
needs to be prepared in connection with the issuance of the exemption.
    4. This exemption is effective as of the date of its issuance.

III. License Amendment Request

    By letter dated June 30, 2015, the licensee requested that the NRC 
amend the COLs for VCSNS, Units 2 and 3, COLs NPF-93 and NPF-94. The 
proposed amendment is described in Section I of this Federal Register 
Notice.
    The Commission has determined for these amendments that the 
application complies with the standards and requirements of the Atomic 
Energy Act of 1954, as amended (the Act), and the Commission's rules 
and regulations. The Commission has made appropriate findings as 
required by the Act and the Commission's rules and regulations in 10 
CFR Chapter I, which are set forth in the license amendment.
    A notice of consideration of issuance of amendment to facility 
operating license or combined license, as applicable, proposed no 
significant hazards consideration determination, and opportunity for a 
hearing in connection with these actions, was published in the Federal 
Register on October 15, 2015 (80 FR 61476). No comments were received 
during the 30-day comment period.
    The Commission has determined that these amendments satisfy the 
criteria for categorical exclusion in accordance with 10 CFR 51.22. 
Therefore, pursuant to 10 CFR 51.22(b), no environmental impact 
statement or environmental assessment need be prepared for these 
amendments.

IV. Conclusion

    Using the reasons set forth in the combined safety evaluation, the 
staff granted the exemption and issued the amendment that the licensee 
requested on June 30, 2015. The exemption and amendment were issued on 
June 2, 2016, as part of a combined package to the licensee (ADAMS 
Accession No. ML16095A115).

    Dated at Rockville, Maryland, this 18th day of July 2016.

    For the Nuclear Regulatory Commission.

Jennifer Dixon-Herrity,
Acting Chief, Licensing Branch 4, Division of New Reactor Licensing, 
Office of New Reactors.
[FR Doc. 2016-17918 Filed 7-27-16; 8:45 am]
BILLING CODE 7590-01-P


Current View
CategoryRegulatory Information
CollectionFederal Register
sudoc ClassAE 2.7:
GS 4.107:
AE 2.106:
PublisherOffice of the Federal Register, National Archives and Records Administration
SectionNotices
ActionExemption and combined license amendment; issuance.
DatesThe exemption and combined license amendment referenced in this document are available on July 28, 2016.
ContactPaul Kallan, Office of New Reactors, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001; telephone: 301-415-2809; email: [email protected]
FR Citation81 FR 49690 