Section 101(c) of the Federal Mine Safety and Health Act of 1977 and Title 30 of the Code of Federal Regulations Part 44 govern the application, processing, and disposition of petitions for modification. This notice is a summary of petitions for modification submitted to the Mine Safety and Health Administration (MSHA) by the parties listed below.

Federal Register, Volume 81 Issue 223 (Friday, November 18, 2016)
[Federal Register Volume 81, Number 223 (Friday, November 18, 2016)]
[Notices]
[Pages 81812-81813]
From the Federal Register Online  [www.thefederalregister.org]
[FR Doc No: 2016-27714]


-----------------------------------------------------------------------

DEPARTMENT OF LABOR


Mine Safety and Health Administration

Petitions for Modification of Application of Existing Mandatory 
Safety Standards

AGENCY: Mine Safety and Health Administration, Labor.

ACTION: Notice.

-----------------------------------------------------------------------

SUMMARY: Section 101(c) of the Federal Mine Safety and Health Act of 
1977 and Title 30 of the Code of Federal Regulations Part 44 govern the 
application, processing, and disposition of petitions for modification. 
This notice is a summary of petitions for modification submitted to the 
Mine Safety and Health Administration (MSHA) by the parties listed 
below.

DATES: All comments on the petitions must be received by MSHA's Office 
of Standards, Regulations, and Variances on or before December 19, 
2016.

ADDRESSES: You may submit your comments, identified by ``docket 
number'' on the subject line, by any of the following methods:
    1. Electronic Mail: [email protected]. Include the docket 
number of the petition in the subject line of the message.
    2. Facsimile: 202-693-9441.
    3. Regular Mail or Hand Delivery: MSHA, Office of Standards, 
Regulations, and Variances, 201 12th Street South, Suite 4E401, 
Arlington, Virginia 22202-5452, Attention: Sheila McConnell, Director, 
Office of Standards, Regulations, and Variances. Persons delivering 
documents are required to check in at the receptionist's desk in Suite 
4E401. Individuals may inspect copies of the petitions and comments 
during normal business hours at the address listed above.
    MSHA will consider only comments postmarked by the U.S. Postal 
Service or proof of delivery from another delivery service such as UPS 
or Federal Express on or before the deadline for comments.

FOR FURTHER INFORMATION CONTACT: Barbara Barron, Office of Standards, 
Regulations, and Variances at 202-693-9447 (Voice), 
[email protected] (Email), or 202-693-9441 (Facsimile). [These are 
not toll-free numbers.]

[[Page 81813]]


SUPPLEMENTARY INFORMATION:

I. Background

    Section 101(c) of the Federal Mine Safety and Health Act of 1977 
(Mine Act) allows the mine operator or representative of miners to file 
a petition to modify the application of any mandatory safety standard 
to a coal or other mine if the Secretary of Labor determines that:
    1. An alternative method of achieving the result of such standard 
exists which will at all times guarantee no less than the same measure 
of protection afforded the miners of such mine by such standard; or
    2. That the application of such standard to such mine will result 
in a diminution of safety to the miners in such mine.
    In addition, the regulations at 30 CFR 44.10 and 44.11 establish 
the requirements and procedures for filing petitions for modification.

II. Petitions for Modification

    Docket Number: M-2016-007-M.
    Petitioner: Vulcan Construction Materials, LLC, 11020 David Taylor 
Drive, Suite 105, Charlotte, NC 28262.
    Mines: Enka Quarry, MSHA I.D. No. 31-00084, located in Buncombe 
County, North Carolina; Rockingham Quarry, MSHA I.D. No. 31-00198, 
located in Richmond County, North Carolina; Lenoir Quarry, MSHA I.D. 
No. 31-01094, located in Caldwell County, North Carolina; Penrose 
Quarry, MSHA I.D. No. 31-00111, located in Transylvania County, North 
Carolina; East Forsyth Quarry, MSHA I.D. No. 31-01919, located in 
Forsyth County, North Carolina; Cabarrus Quarry, MSHA I.D. No. 31-
01357, located in Cabarrus County, North Carolina; and Clear Creek 
Quarry, MSHA I.D. No. 31-02087, located in Mecklenburg County, North 
Carolina.
    Regulation Affected: 30 CFR 56.13010 (Reciprocating-type air 
compressors).
    Modification Request: The petitioner requests a modification of the 
existing standard to allow the designated compressors outlined in this 
petition to be considered in compliance with the existing standard. The 
petitioner states that:
    (1) The compressor industry guidance has shown that the high 
temperature shutoff switch is not offered as a standard safety feature 
on an electrically motor-driven reciprocating-type air compressor 
between 2 horsepower and 30 horsepower. The only time a high 
temperature shutoff switch is used on a reciprocating-type compressor 
is when very large compressors (100 horsepower and up) are housed in 
buildings or containers that could allow intake air to be heated by 
other environmental influences. However, a high temperature shutoff 
switch has always been standard for a rotary or screw type compressor 
that is working off of a combustion engine. When discussing this 
standard with compressor manufacturers, the first statement that is 
often made is ``are you sure we are referring to a rotary compressor 
not a reciprocating compressor''.
    (2) The petitioner states the following facts related to electric 
motor-driven reciprocating air compressors:
    (a) The electric motor does not affect the temperature of the air 
in the compressor. The compressor and motor are only connected to 
sheaves on both sides.
    (b) Existing 30 CFR 56.13010 states that the temperature switch 
must be adjusted to shut down the compressor when the normal operating 
temperature is exceeded by more than 25 percent. This would be 
virtually impossible because the normal operating temperature is 
affected by the intake air temperature which can fluctuate by 30 
percent or more depending on the geographic location of the air 
compressor and the time of the year. According to manufacturers, the 
temperatures of supplied air can typically range from 32 degrees 
Fahrenheit to 115 degrees Fahrenheit. Due to the fluctuation in 
temperature ranges, the system could almost never be set to the actual 
25 percent above normal temperature. In addition, the temperature of 
the intake air affects the density of the air which changes the amount 
of air being compressed during the process. The phenomenon directly 
affects the output temperature of the air.
    (c) High temperature shutoff switches are considered unreliable in 
many applications because there is no true way to test whether the 
switch is actually working. To test a high temperature shutoff switch, 
the temperature would have to be altered to determine if the switch is 
working properly, which raises safety concerns.
    (d) High temperature switches are also very costly and in cases 
where it was not provided as standard equipment by the manufacturer, 
installing a switch could void warranty and UL listing of a compressor 
if not installed by a certified manufacturer's representative. Not all 
States have compressor inspection programs, which could potentially 
allow an unqualified person to install a switch to meet the MSHA 
standard resulting in potential hazards to persons from a possible 
faulty installation.
    (e) The units included in this petition currently are equipped with 
multiple safety features that include most of the following:

--Magnetic starter--prevents motor from electrical overload.
-- Low oil level switch--prevents unit from operating in low oil 
conditions.
-- Aftercoolers--cools discharge air that allows moisture to condense 
in the tank.
--Automatic condensate drain--ensures removal of water from tank.
--Unloader valve--relieves pressure on compressor head when unit shuts 
off. This prevents unit starting underload.
--Safety relief valves--relieves tank pressure at a set PSI to prevent 
over pressurization of tank. Line pressure relief valves are also 
utilized at aftercoolers.
--Tank pressure switch--cuts off pressure at a set normal PSI range.
--High amp fuse--cuts off motor if high amps are achieved.

    The petitioner further asserts that industry data suggests that the 
current safety devices as equipped on the compressors offer equal 
protection to the standard even if they are not equipped with the 
automatic temperature actuated shutoff mechanism.

Sheila McConnell,
Director, Office of Standards, Regulations, and Variances.
[FR Doc. 2016-27714 Filed 11-17-16; 8:45 am]
 BILLING CODE 4520-43-P



                                                  81812                       Federal Register / Vol. 81, No. 223 / Friday, November 18, 2016 / Notices

                                                  the last open crosscut will be examined                 nonpermissible electronic testing or                  less than the same measure of protection
                                                  by a qualified person (as defined in 30                 diagnostic equipment in return air outby              afforded by the existing standard.
                                                  CFR 75.153) prior to use to ensure the                  the last open crosscut. The petitioner                Sheila McConnell,
                                                  equipment is being maintained in a safe                 states that:
                                                  operating condition. The examination                                                                          Director, Office of Standards, Regulations,
                                                                                                            (1) Nonpermissible electronic testing               and Variances.
                                                  results will be recorded weekly in the                  and diagnostic equipment to be used                   [FR Doc. 2016–27713 Filed 11–17–16; 8:45 am]
                                                  examination book and will be made
                                                                                                          includes: Laptop/tablet computers,                    BILLING CODE 4520–43–P
                                                  available to MSHA and the miners at the
                                                                                                          oscilloscopes, vibration analysis
                                                  mine.
                                                                                                          machines, cable fault detectors, point
                                                     (3) A qualified person as defined in
                                                  existing 30 CFR 75.151 will                             temperature probes, infrared                          DEPARTMENT OF LABOR
                                                  continuously monitor for methane                        temperature devices, insulation testers
                                                                                                          (meggers), voltage, current, resistance               Mine Safety and Health Administration
                                                  immediately before and during the use
                                                  of nonpermissible electronic testing and                meters and power testers, and electronic
                                                                                                          tachometers. Other testing and                        Petitions for Modification of
                                                  diagnostic equipment in or inby the last                                                                      Application of Existing Mandatory
                                                  open crosscut.                                          diagnostic equipment may be used if
                                                                                                          approved in advance by the MSHA                       Safety Standards
                                                     (4) Nonpermissible electronic testing
                                                  and diagnostic equipment will not be                    District Manager.                                     AGENCY: Mine Safety and Health
                                                  used if methane is detected in                            (2) All nonpermissible testing and                  Administration, Labor.
                                                  concentrations at or above 1.0 percent.                 diagnostic equipment used in return air               ACTION: Notice.
                                                  When 1.0 percent or more methane is                     outby the last open crosscut will be
                                                  detected while the nonpermissible                       examined by a qualified person (as                    SUMMARY:    Section 101(c) of the Federal
                                                  electronic equipment is being used, the                 defined in 30 CFR 75.153) prior to use                Mine Safety and Health Act of 1977 and
                                                  equipment will be deenergized                                                                                 Title 30 of the Code of Federal
                                                                                                          to ensure the equipment is being
                                                  immediately and withdrawn outby the                                                                           Regulations Part 44 govern the
                                                                                                          maintained in a safe operating
                                                  last open crosscut.                                                                                           application, processing, and disposition
                                                                                                          condition. The examination results will
                                                     (5) All hand-held methane detectors                                                                        of petitions for modification. This notice
                                                                                                          be recorded weekly in the examination
                                                  will be MSHA-approved and                                                                                     is a summary of petitions for
                                                                                                          book and will be made available to                    modification submitted to the Mine
                                                  maintained in permissible and proper                    MSHA and the miners at the mine.
                                                  operating condition as defined in 30                                                                          Safety and Health Administration
                                                  CFR 75.320.                                               (3) A qualified person as defined in                (MSHA) by the parties listed below.
                                                     (6) Except for time necessary to                     existing 30 CFR 75.151 will                           DATES: All comments on the petitions
                                                  troubleshoot under actual mining                        continuously monitor for methane                      must be received by MSHA’s Office of
                                                  conditions, coal production on MMU                      immediately before and during the use                 Standards, Regulations, and Variances
                                                  will cease. However, coal may remain in                 of nonpermissible electronic testing and              on or before December 19, 2016.
                                                  or on the equipment to test and                         diagnostic equipment in return air outby              ADDRESSES: You may submit your
                                                  diagnose the equipment under ‘‘load.’’                  the last open crosscut.                               comments, identified by ‘‘docket
                                                     (7) All electronic testing and                         (4) Nonpermissible electronic testing               number’’ on the subject line, by any of
                                                  diagnostic equipment will be used in                    and diagnostic equipment will not be                  the following methods:
                                                  accordance with the manufacturer’s                      used if methane is detected in                           1. Electronic Mail: zzMSHA-
                                                  recommendations.                                        concentrations at or above 1.0 percent.               comments@dol.gov. Include the docket
                                                     (8) Qualified personnel who use                      When 1.0 percent or more methane is                   number of the petition in the subject
                                                  electronic testing and diagnostic                       detected while the nonpermissible                     line of the message.
                                                  equipment will be properly trained to                   electronic equipment is being used, the                  2. Facsimile: 202–693–9441.
                                                  recognize the hazards and limitations                   equipment will be deenergized                            3. Regular Mail or Hand Delivery:
                                                  associated with use of the equipment.                   immediately and withdrawn from the                    MSHA, Office of Standards,
                                                     The petitioner asserts that under the                                                                      Regulations, and Variances, 201 12th
                                                                                                          return air outby the last open crosscut.
                                                  terms and conditions of the petition for                                                                      Street South, Suite 4E401, Arlington,
                                                  modification, the use of nonpermissible                   (5) All hand-held methane detectors                 Virginia 22202–5452, Attention: Sheila
                                                  electronic testing and diagnostic                       will be MSHA-approved and                             McConnell, Director, Office of
                                                  equipment will at all times guarantee no                maintained in permissible and proper                  Standards, Regulations, and Variances.
                                                  less than the same measure of protection                operating condition as defined in 30                  Persons delivering documents are
                                                  afforded by the existing standard.                      CFR 75.320.                                           required to check in at the receptionist’s
                                                     Docket Number: M–2016–035–C.                           (6) All electronic testing and                      desk in Suite 4E401. Individuals may
                                                     Petitioner: Warrior Coal, LLC, 57 J.E.               diagnostic equipment will be used in                  inspect copies of the petitions and
                                                  Ellis Rd., Madisonville, Kentucky                       accordance with the manufacturer’s                    comments during normal business
                                                  42431.                                                  recommendations.                                      hours at the address listed above.
                                                     Mine: Warrior’s Cardinal Mine,                                                                                MSHA will consider only comments
                                                                                                            (7) Qualified personnel who use                     postmarked by the U.S. Postal Service or
                                                  MSHA I.D. No. 15–14335, located in
                                                                                                          electronic testing and diagnostic                     proof of delivery from another delivery
                                                  Hopkins County, Kentucky.
                                                                                                          equipment will be properly trained to                 service such as UPS or Federal Express
                                                     Regulation Affected: 30 CFR 75.507–
mstockstill on DSK3G9T082PROD with NOTICES




                                                                                                          recognize the hazards and limitations                 on or before the deadline for comments.
                                                  1(a) (Electric equipment other than
                                                  power-connection points; outby the last                 associated with use of the equipment.
                                                                                                                                                                FOR FURTHER INFORMATION CONTACT:
                                                  open crosscut; return air; permissibility                 The petitioner asserts that under the               Barbara Barron, Office of Standards,
                                                  requirements).                                          terms and conditions of the petition for              Regulations, and Variances at 202–693–
                                                     Modification Request: The petitioner                 modification, the use of nonpermissible               9447 (Voice), barron.barbara@dol.gov
                                                  requests a modification of the existing                 electronic testing and diagnostic                     (Email), or 202–693–9441 (Facsimile).
                                                  standard to permit the use of                           equipment will at all times guarantee no              [These are not toll-free numbers.]


                                             VerDate Sep<11>2014   20:21 Nov 17, 2016   Jkt 241001   PO 00000   Frm 00094   Fmt 4703   Sfmt 4703   E:\FR\FM\18NON1.SGM   18NON1


                                                                              Federal Register / Vol. 81, No. 223 / Friday, November 18, 2016 / Notices                                                81813

                                                  SUPPLEMENTARY INFORMATION:                              containers that could allow intake air to             safety features that include most of the
                                                                                                          be heated by other environmental                      following:
                                                  I. Background
                                                                                                          influences. However, a high temperature               —Magnetic starter—prevents motor
                                                     Section 101(c) of the Federal Mine                   shutoff switch has always been standard                 from electrical overload.
                                                  Safety and Health Act of 1977 (Mine                     for a rotary or screw type compressor                 — Low oil level switch—prevents unit
                                                  Act) allows the mine operator or                        that is working off of a combustion                     from operating in low oil conditions.
                                                  representative of miners to file a                      engine. When discussing this standard                 — Aftercoolers—cools discharge air that
                                                  petition to modify the application of any               with compressor manufacturers, the first                allows moisture to condense in the
                                                  mandatory safety standard to a coal or                  statement that is often made is ‘‘are you               tank.
                                                  other mine if the Secretary of Labor                    sure we are referring to a rotary                     —Automatic condensate drain—ensures
                                                  determines that:                                        compressor not a reciprocating                          removal of water from tank.
                                                     1. An alternative method of achieving                compressor’’.                                         —Unloader valve—relieves pressure on
                                                  the result of such standard exists which                   (2) The petitioner states the following              compressor head when unit shuts off.
                                                  will at all times guarantee no less than                facts related to electric motor-driven                  This prevents unit starting underload.
                                                  the same measure of protection afforded                 reciprocating air compressors:                        —Safety relief valves—relieves tank
                                                  the miners of such mine by such                            (a) The electric motor does not affect               pressure at a set PSI to prevent over
                                                  standard; or                                            the temperature of the air in the                       pressurization of tank. Line pressure
                                                     2. That the application of such                      compressor. The compressor and motor                    relief valves are also utilized at
                                                  standard to such mine will result in a                  are only connected to sheaves on both                   aftercoolers.
                                                  diminution of safety to the miners in                   sides.                                                —Tank pressure switch—cuts off
                                                  such mine.                                                 (b) Existing 30 CFR 56.13010 states                  pressure at a set normal PSI range.
                                                     In addition, the regulations at 30 CFR               that the temperature switch must be                   —High amp fuse—cuts off motor if high
                                                  44.10 and 44.11 establish the                           adjusted to shut down the compressor                    amps are achieved.
                                                  requirements and procedures for filing                  when the normal operating temperature
                                                                                                          is exceeded by more than 25 percent.                    The petitioner further asserts that
                                                  petitions for modification.
                                                                                                          This would be virtually impossible                    industry data suggests that the current
                                                  II. Petitions for Modification                          because the normal operating                          safety devices as equipped on the
                                                     Docket Number: M–2016–007–M.                         temperature is affected by the intake air             compressors offer equal protection to
                                                     Petitioner: Vulcan Construction                      temperature which can fluctuate by 30                 the standard even if they are not
                                                  Materials, LLC, 11020 David Taylor                      percent or more depending on the                      equipped with the automatic
                                                  Drive, Suite 105, Charlotte, NC 28262.                  geographic location of the air                        temperature actuated shutoff
                                                     Mines: Enka Quarry, MSHA I.D. No.                    compressor and the time of the year.                  mechanism.
                                                  31–00084, located in Buncombe County,                   According to manufacturers, the                       Sheila McConnell,
                                                  North Carolina; Rockingham Quarry,                      temperatures of supplied air can                      Director, Office of Standards, Regulations,
                                                  MSHA I.D. No. 31–00198, located in                      typically range from 32 degrees                       and Variances.
                                                  Richmond County, North Carolina;                        Fahrenheit to 115 degrees Fahrenheit.                 [FR Doc. 2016–27714 Filed 11–17–16; 8:45 am]
                                                  Lenoir Quarry, MSHA I.D. No. 31–                        Due to the fluctuation in temperature                 BILLING CODE 4520–43–P
                                                  01094, located in Caldwell County,                      ranges, the system could almost never
                                                  North Carolina; Penrose Quarry, MSHA                    be set to the actual 25 percent above
                                                  I.D. No. 31–00111, located in                           normal temperature. In addition, the
                                                  Transylvania County, North Carolina;                                                                          LEGAL SERVICES CORPORATION
                                                                                                          temperature of the intake air affects the
                                                  East Forsyth Quarry, MSHA I.D. No. 31–                  density of the air which changes the                  Sunshine Act Meeting: Board of
                                                  01919, located in Forsyth County, North                 amount of air being compressed during                 Directors and Operations &
                                                  Carolina; Cabarrus Quarry, MSHA I.D.                    the process. The phenomenon directly                  Regulations Committee Telephonic
                                                  No. 31–01357, located in Cabarrus                       affects the output temperature of the air.            Meetings
                                                  County, North Carolina; and Clear Creek                    (c) High temperature shutoff switches
                                                  Quarry, MSHA I.D. No. 31–02087,                         are considered unreliable in many                     AGENCY:    Legal Services Corporation
                                                  located in Mecklenburg County, North                    applications because there is no true                 ACTION:   Change Notice
                                                  Carolina.                                               way to test whether the switch is
                                                     Regulation Affected: 30 CFR 56.13010                 actually working. To test a high                      SUMMARY:   On November 6, 2016, the
                                                  (Reciprocating-type air compressors).                   temperature shutoff switch, the                       Legal Services Corporation (LSC)
                                                     Modification Request: The petitioner                 temperature would have to be altered to               published a notice in the Federal
                                                  requests a modification of the existing                 determine if the switch is working                    Register (81 FR 80686) titled ‘‘Board of
                                                  standard to allow the designated                        properly, which raises safety concerns.               Directors will meet telephonically on
                                                  compressors outlined in this petition to                   (d) High temperature switches are also             November 22, 2016. The meeting will
                                                  be considered in compliance with the                    very costly and in cases where it was                 commence at 2:00 Eastern Standard
                                                  existing standard. The petitioner states                not provided as standard equipment by                 Time (EST). Immediately following the
                                                  that:                                                   the manufacturer, installing a switch                 Board of Directors telephonic meeting,
                                                     (1) The compressor industry guidance                 could void warranty and UL listing of a               the Operations and Regulations
                                                  has shown that the high temperature                     compressor if not installed by a certified            Committee will hold a telephonic
                                                  shutoff switch is not offered as a                      manufacturer’s representative. Not all                meeting.’’ A correction to change item
                                                  standard safety feature on an electrically              States have compressor inspection                     #2 on the Board of Directors Agenda to
mstockstill on DSK3G9T082PROD with NOTICES




                                                  motor-driven reciprocating-type air                     programs, which could potentially                     read; Consider and act on the Board of
                                                  compressor between 2 horsepower and                     allow an unqualified person to install a              Directors’ transmittal to accompany the
                                                  30 horsepower. The only time a high                     switch to meet the MSHA standard                      Inspector General’s Semiannual Report
                                                  temperature shutoff switch is used on a                 resulting in potential hazards to persons             to Congress for the period of April 1,
                                                  reciprocating-type compressor is when                   from a possible faulty installation.                  2016 through September 30, 2016, all
                                                  very large compressors (100 horsepower                     (e) The units included in this petition            other items remain consecutively the
                                                  and up) are housed in buildings or                      currently are equipped with multiple                  same. This document changes the notice


                                             VerDate Sep<11>2014   20:21 Nov 17, 2016   Jkt 241001   PO 00000   Frm 00095   Fmt 4703   Sfmt 4703   E:\FR\FM\18NON1.SGM   18NON1



Document Created: 2018-02-14 08:31:55
Document Modified: 2018-02-14 08:31:55
CategoryRegulatory Information
CollectionFederal Register
sudoc ClassAE 2.7:
GS 4.107:
AE 2.106:
PublisherOffice of the Federal Register, National Archives and Records Administration
SectionNotices
ActionNotice.
DatesAll comments on the petitions must be received by MSHA's Office of Standards, Regulations, and Variances on or before December 19, 2016.
ContactBarbara Barron, Office of Standards, Regulations, and Variances at 202-693-9447 (Voice), [email protected] (Email), or 202-693-9441 (Facsimile). [These are not toll-free numbers.]
FR Citation81 FR 81812 