82_FR_26628 82 FR 26520 - South Carolina Electric & Gas Company; South Carolina Public Service Authority, Virgil C. Summer Nuclear Station, Units 2 and 3; Passive Core Cooling System (PXS) Condensate Return

82 FR 26520 - South Carolina Electric & Gas Company; South Carolina Public Service Authority, Virgil C. Summer Nuclear Station, Units 2 and 3; Passive Core Cooling System (PXS) Condensate Return

NUCLEAR REGULATORY COMMISSION

Federal Register Volume 82, Issue 108 (June 7, 2017)

Page Range26520-26521
FR Document2017-11803

The U.S. Nuclear Regulatory Commission (NRC) is granting an exemption to allow a departure from the certification information of Tier 1 of the generic design control document (DCD) and is issuing License Amendment No. 61 to Combined Licenses (COL), NPF-93 and NPF-94, respectively. The COLs were issued to South Carolina Electric & Gas Company and the South Carolina Public Service Authority, (both collectively referred to as the licensee) for construction and operation of the Virgil C. Summer Nuclear Station (VCSNS) Units 2 and 3, located in Fairfield County, South Carolina. The granting of the exemption allows the changes to Tier 1 information asked for in the amendment. Because the acceptability of the exemption was determined in part by the acceptability of the amendment, the exemption and amendment are being issued concurrently.

Federal Register, Volume 82 Issue 108 (Wednesday, June 7, 2017)
[Federal Register Volume 82, Number 108 (Wednesday, June 7, 2017)]
[Notices]
[Pages 26520-26521]
From the Federal Register Online  [www.thefederalregister.org]
[FR Doc No: 2017-11803]


-----------------------------------------------------------------------

NUCLEAR REGULATORY COMMISSION

[Docket Nos. 52-027 and 52-028; NRC-2008-0441]


South Carolina Electric & Gas Company; South Carolina Public 
Service Authority, Virgil C. Summer Nuclear Station, Units 2 and 3; 
Passive Core Cooling System (PXS) Condensate Return

AGENCY: Nuclear Regulatory Commission.

ACTION: Exemption and combined license amendment; issuance.

-----------------------------------------------------------------------

SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) is granting an 
exemption to allow a departure from the certification information of 
Tier 1 of the generic design control document (DCD) and is issuing 
License Amendment No. 61 to Combined Licenses (COL), NPF-93 and NPF-94, 
respectively. The COLs were issued to South Carolina Electric & Gas 
Company and the South Carolina Public Service Authority, (both 
collectively referred to as the licensee) for construction and 
operation of the Virgil C. Summer Nuclear Station (VCSNS) Units 2 and 
3, located in Fairfield County, South Carolina.
    The granting of the exemption allows the changes to Tier 1 
information asked for in the amendment. Because the acceptability of 
the exemption was determined in part by the acceptability of the 
amendment, the exemption and amendment are being issued concurrently.

DATES: The exemption and amendment were issued on February 28, 2017.

ADDRESSES: Please refer to Docket ID NRC-2008-0441 when contacting the 
NRC about the availability of information regarding this document. You 
may obtain publicly-available information related to this document 
using any of the following methods:
     Federal Rulemaking Web site: Go to http://www.regulations.gov and search for Docket ID NRC-2008-0441. Address 
questions about NRC dockets to Carol Gallagher; telephone: 301-415-
3463; email: [email protected]. For technical questions, contact 
the individual listed in the FOR FURTHER INFORMATION CONTACT section of 
this document.
     NRC's Agencywide Documents Access and Management System 
(ADAMS): You may obtain publicly-available documents online in the 
ADAMS Public Documents collection at http://www.nrc.gov/reading-rm/adams.html. To begin the search, select ``ADAMS Public Documents'' and 
then select ``Begin Web-based ADAMS Search.'' For problems with ADAMS, 
please contact the NRC's Public Document Room (PDR) reference staff at 
1-800-397-4209, 301-415-4737, or by email to [email protected]. The 
ADAMS accession number for each document referenced (if it is available 
in ADAMS) is provided the first time that it is mentioned in this 
document. The request for the amendment and exemption was submitted by 
letter dated November 18, 2016 (ADAMS Accession No. ML16323A335).
     NRC's PDR: You may examine and purchase copies of public 
documents at the NRC's PDR, Room O1-F21, One White Flint North, 11555 
Rockville Pike, Rockville, Maryland 20852.

FOR FURTHER INFORMATION CONTACT: Ruth C. Reyes, Office of New Reactors, 
U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001; 
telephone: 301-415-3249; email: [email protected].

SUPPLEMENTARY INFORMATION: 

I. Introduction

    The NRC is granting an exemption from paragraph B of section III, 
``Scope and Contents,'' of appendix D, ``Design Certification Rule for 
the AP1000,'' to part 52 of title 10 of the Code of Federal Regulations 
(10 CFR), and issuing License Amendment No. 61 to COLs, NPF-93 and NPF-
94, to the licensee. The exemption is required by Paragraph A.4 of 
Section VIII, ``Processes for Changes and Departures,'' of appendix D, 
to 10 CFR part 52 to allow the licensee to depart from Tier 1 
information. The amendment authorizes changes to the VCSNS Units 2 and 
3 Updated Final Safety Analysis Report in the form of departures from 
the incorporated plant specific DCD Tier 2 information, proposes to 
depart from involved plant-specific Tier 1 information (and associated 
COL Appendix C information) and from involved plant-specific Technical 
Specifications as incorporated in Appendix A of the COL. With the 
requested amendment, the licensee proposed changes to reflect an 
increase in the efficiency of the return of condensate utilized by the 
passive core cooling system to the in-containment refueling water 
storage tank to support the capability for long-term cooling.
    Part of the justification for granting the exemption was provided 
by the review of the amendment. Because the exemption is necessary in 
order to issue the requested license amendment, the NRC granted the 
exemption and issued the amendment concurrently, rather than in 
sequence. This included issuing a combined safety evaluation containing 
the NRC staff's review of both the exemption request and the license 
amendment. The exemption met all applicable regulatory criteria set 
forth in 10 CFR 50.12, 10 CFR 52.7, and Section VIII.A.4 of appendix D 
to 10 CFR part 52. The license amendment was found to be acceptable as 
well. The combined safety evaluation is available in ADAMS under 
Accession No. ML17026A479.
    Identical exemption documents (except for referenced unit numbers 
and license numbers) were issued to the licensee for VCSNS Units 2 and 
3 (COLs NPF-93 and NPF-94). The exemption documents for VCSNS Units 2 
and 3 can be found in ADAMS under Accession Nos. ML17026A400 and 
ML17026A410, respectively. The exemption is reproduced (with the 
exception of abbreviated titles and additional citations) in Section II 
of this document. The amendment documents for COLs NPF-93 and NPF-94 
are available in ADAMS under Accession Nos. ML17026A391 and 
ML17026A398, respectively. A summary of the amendment documents is 
provided in Section III of this document.

II. Exemption

    Reproduced below is the exemption document issued to VCSNS Units 2 
and Unit 3. It makes reference to the combined safety evaluation that 
provides the reasoning for the findings made by the NRC (and listed 
under Item 1) in order to grant the exemption:
    1. In a letter dated November 18, 2016, the licensee requested from 
the Commission an exemption to allow departures from Tier 1 information 
in the certified DCD incorporated by reference in 10 CFR part 52, 
appendix D, as part of license amendment request 16-06, ``Passive Core 
Cooling System (PXS) Condensate Return.''

[[Page 26521]]

    For the reasons set forth in Section 3.0 of the NRC staff's Safety 
Evaluation, which can be found in ADAMS under Accession No. 
ML17026A479, the Commission finds that:
    A. The exemption is authorized by law;
    B. the exemption presents no undue risk to public health and 
safety;
    C. the exemption is consistent with the common defense and 
security;
    D. special circumstances are present in that the application of the 
rule in this circumstance is not necessary to serve the underlying 
purpose of the rule;
    E. the special circumstances outweigh any decrease in safety that 
may result from the reduction in standardization caused by the 
exemption; and
    F. the exemption will not result in a significant decrease in the 
level of safety otherwise provided by the design.
    2. Accordingly, the licensee is granted an exemption from the 
certified DCD Tier 1 information, with corresponding changes to 
Appendix C of the Facility Combined Licenses as described in the 
licensee's request dated November 18, 2016. This exemption is related 
to, and necessary for the granting of License Amendment No. 61, which 
is being issued concurrently with this exemption.
    3. As explained in Section 5.0 of the NRC staff's Safety Evaluation 
(ADAMS Accession No. ML17026A479), this exemption meets the eligibility 
criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). 
Therefore, pursuant to 10 CFR 51.22(b), no environmental impact 
statement or environmental assessment needs to be prepared in 
connection with the issuance of the exemption.
    4. This exemption is effective as of the date of its issuance.

III. License Amendment Request

    By letter dated November 18, 2016 (ADAMS Accession No. 
ML16323A335), the licensee requested that the NRC amend the COLs for 
VCSNS, Units 2 and 3, COLs NPF-93 and NPF-94. The proposed amendment is 
described in Section I of this Federal Register notice.
    The Commission has determined for these amendments that the 
application complies with the standards and requirements of the Atomic 
Energy Act of 1954, as amended (the Act), and the Commission's rules 
and regulations. The Commission has made appropriate findings as 
required by the Act and the Commission's rules and regulations in 10 
CFR Chapter I, which are set forth in the license amendment.
    A notice of consideration of issuance of amendment to facility 
operating license or COL, as applicable, proposed no significant 
hazards consideration determination, and opportunity for a hearing in 
connection with these actions, was published in the Federal Register on 
December 15, 2016 (81 FR 90871). No comments were received during the 
30-day comment period.
    The Commission has determined that these amendments satisfy the 
criteria for categorical exclusion in accordance with 10 CFR 51.22. 
Therefore, pursuant to 10 CFR 51.22(b), no environmental impact 
statement or environmental assessment need be prepared for these 
amendments.

IV. Conclusion

    Using the reasons set forth in the combined safety evaluation, the 
staff granted the exemption and issued the amendment that the licensee 
requested on letter dated November 18, 2016. The exemption and 
amendment were issued on February 28, 2017, as part of a combined 
package to the licensee (ADAMS Accession No. ML17026A381).

    Dated at Rockville, Maryland, this 30th day of May 2017.

    For the Nuclear Regulatory Commission.
Jennifer Dixon-Herrity,
Chief, Licensing Branch 4, Division of New Reactor Licensing, Office of 
New Reactors.
[FR Doc. 2017-11803 Filed 6-6-17; 8:45 am]
 BILLING CODE 7590-01-P



                                                26520                         Federal Register / Vol. 82, No. 108 / Wednesday, June 7, 2017 / Notices

                                                persons planning to attend should check                 information related to this document                   information (and associated COL
                                                with these references if such                           using any of the following methods:                    Appendix C information) and from
                                                rescheduling would result in a major                       • Federal Rulemaking Web site: Go to                involved plant-specific Technical
                                                inconvenience.                                          http://www.regulations.gov and search                  Specifications as incorporated in
                                                  If attending this meeting, please enter               for Docket ID NRC–2008–0441. Address                   Appendix A of the COL. With the
                                                through the One White Flint North                       questions about NRC dockets to Carol                   requested amendment, the licensee
                                                building, 11555 Rockville Pike,                         Gallagher; telephone: 301–415–3463;                    proposed changes to reflect an increase
                                                Rockville, Maryland 20852. After                        email: Carol.Gallagher@nrc.gov. For                    in the efficiency of the return of
                                                registering with Security, please contact               technical questions, contact the                       condensate utilized by the passive core
                                                Mr. Theron Brown (Telephone 240–                        individual listed in the FOR FURTHER                   cooling system to the in-containment
                                                888–9835) to be escorted to the meeting                 INFORMATION CONTACT section of this                    refueling water storage tank to support
                                                room.                                                   document.                                              the capability for long-term cooling.
                                                  Dated: May 31, 2017.                                     • NRC’s Agencywide Documents                           Part of the justification for granting
                                                Mark L. Banks,
                                                                                                        Access and Management System                           the exemption was provided by the
                                                                                                        (ADAMS): You may obtain publicly-                      review of the amendment. Because the
                                                Chief, Technical Support Branch, Advisory
                                                Committee on Reactor Safeguards.
                                                                                                        available documents online in the                      exemption is necessary in order to issue
                                                                                                        ADAMS Public Documents collection at                   the requested license amendment, the
                                                [FR Doc. 2017–11799 Filed 6–6–17; 8:45 am]
                                                                                                        http://www.nrc.gov/reading-rm/                         NRC granted the exemption and issued
                                                BILLING CODE 7590–01–P
                                                                                                        adams.html. To begin the search, select                the amendment concurrently, rather
                                                                                                        ‘‘ADAMS Public Documents’’ and then                    than in sequence. This included issuing
                                                                                                        select ‘‘Begin Web-based ADAMS                         a combined safety evaluation containing
                                                NUCLEAR REGULATORY
                                                                                                        Search.’’ For problems with ADAMS,                     the NRC staff’s review of both the
                                                COMMISSION
                                                                                                        please contact the NRC’s Public                        exemption request and the license
                                                [Docket Nos. 52–027 and 52–028; NRC–                    Document Room (PDR) reference staff at                 amendment. The exemption met all
                                                2008–0441]                                              1–800–397–4209, 301–415–4737, or by                    applicable regulatory criteria set forth in
                                                                                                        email to pdr.resource@nrc.gov. The                     10 CFR 50.12, 10 CFR 52.7, and Section
                                                South Carolina Electric & Gas                           ADAMS accession number for each
                                                Company; South Carolina Public                                                                                 VIII.A.4 of appendix D to 10 CFR part
                                                                                                        document referenced (if it is available in             52. The license amendment was found
                                                Service Authority, Virgil C. Summer                     ADAMS) is provided the first time that
                                                Nuclear Station, Units 2 and 3; Passive                                                                        to be acceptable as well. The combined
                                                                                                        it is mentioned in this document. The                  safety evaluation is available in ADAMS
                                                Core Cooling System (PXS)                               request for the amendment and
                                                Condensate Return                                                                                              under Accession No. ML17026A479.
                                                                                                        exemption was submitted by letter                         Identical exemption documents
                                                AGENCY:  Nuclear Regulatory                             dated November 18, 2016 (ADAMS                         (except for referenced unit numbers and
                                                Commission.                                             Accession No. ML16323A335).                            license numbers) were issued to the
                                                ACTION: Exemption and combined                             • NRC’s PDR: You may examine and                    licensee for VCSNS Units 2 and 3 (COLs
                                                license amendment; issuance.                            purchase copies of public documents at                 NPF–93 and NPF–94). The exemption
                                                                                                        the NRC’s PDR, Room O1–F21, One                        documents for VCSNS Units 2 and 3 can
                                                SUMMARY:    The U.S. Nuclear Regulatory                 White Flint North, 11555 Rockville                     be found in ADAMS under Accession
                                                Commission (NRC) is granting an                         Pike, Rockville, Maryland 20852.                       Nos. ML17026A400 and ML17026A410,
                                                exemption to allow a departure from the                 FOR FURTHER INFORMATION CONTACT:                       respectively. The exemption is
                                                certification information of Tier 1 of the              Ruth C. Reyes, Office of New Reactors,                 reproduced (with the exception of
                                                generic design control document (DCD)                   U.S. Nuclear Regulatory Commission,                    abbreviated titles and additional
                                                and is issuing License Amendment No.                    Washington, DC 20555–0001; telephone:                  citations) in Section II of this document.
                                                61 to Combined Licenses (COL), NPF–                     301–415–3249; email: Ruth.Reyes@                       The amendment documents for COLs
                                                93 and NPF–94, respectively. The COLs                   nrc.gov.                                               NPF–93 and NPF–94 are available in
                                                were issued to South Carolina Electric &                                                                       ADAMS under Accession Nos.
                                                                                                        SUPPLEMENTARY INFORMATION:
                                                Gas Company and the South Carolina                                                                             ML17026A391 and ML17026A398,
                                                Public Service Authority, (both                         I. Introduction                                        respectively. A summary of the
                                                collectively referred to as the licensee)                  The NRC is granting an exemption                    amendment documents is provided in
                                                for construction and operation of the                   from paragraph B of section III, ‘‘Scope               Section III of this document.
                                                Virgil C. Summer Nuclear Station                        and Contents,’’ of appendix D, ‘‘Design
                                                (VCSNS) Units 2 and 3, located in                                                                              II. Exemption
                                                                                                        Certification Rule for the AP1000,’’ to
                                                Fairfield County, South Carolina.                       part 52 of title 10 of the Code of Federal               Reproduced below is the exemption
                                                  The granting of the exemption allows                                                                         document issued to VCSNS Units 2 and
                                                                                                        Regulations (10 CFR), and issuing
                                                the changes to Tier 1 information asked                                                                        Unit 3. It makes reference to the
                                                                                                        License Amendment No. 61 to COLs,
                                                for in the amendment. Because the                                                                              combined safety evaluation that
                                                                                                        NPF–93 and NPF–94, to the licensee.
                                                acceptability of the exemption was                                                                             provides the reasoning for the findings
                                                                                                        The exemption is required by Paragraph
                                                determined in part by the acceptability                                                                        made by the NRC (and listed under Item
                                                                                                        A.4 of Section VIII, ‘‘Processes for
                                                of the amendment, the exemption and                                                                            1) in order to grant the exemption:
                                                                                                        Changes and Departures,’’ of appendix
                                                amendment are being issued
                                                                                                        D, to 10 CFR part 52 to allow the                        1. In a letter dated November 18,
                                                concurrently.
                                                                                                        licensee to depart from Tier 1                         2016, the licensee requested from the
sradovich on DSK3GMQ082PROD with NOTICES




                                                DATES: The exemption and amendment                      information. The amendment authorizes                  Commission an exemption to allow
                                                were issued on February 28, 2017.                       changes to the VCSNS Units 2 and 3                     departures from Tier 1 information in
                                                ADDRESSES: Please refer to Docket ID                    Updated Final Safety Analysis Report in                the certified DCD incorporated by
                                                NRC–2008–0441 when contacting the                       the form of departures from the                        reference in 10 CFR part 52, appendix
                                                NRC about the availability of                           incorporated plant specific DCD Tier 2                 D, as part of license amendment request
                                                information regarding this document.                    information, proposes to depart from                   16–06, ‘‘Passive Core Cooling System
                                                You may obtain publicly-available                       involved plant-specific Tier 1                         (PXS) Condensate Return.’’


                                           VerDate Sep<11>2014   16:37 Jun 06, 2017   Jkt 241001   PO 00000   Frm 00098   Fmt 4703   Sfmt 4703   E:\FR\FM\07JNN1.SGM   07JNN1


                                                                              Federal Register / Vol. 82, No. 108 / Wednesday, June 7, 2017 / Notices                                                  26521

                                                   For the reasons set forth in Section 3.0             no significant hazards consideration                      The NRC Commission Meeting
                                                of the NRC staff’s Safety Evaluation,                   determination, and opportunity for a                   Schedule can be found on the Internet
                                                which can be found in ADAMS under                       hearing in connection with these                       at: http://www.nrc.gov/public-involve/
                                                Accession No. ML17026A479, the                          actions, was published in the Federal                  public-meetings/schedule.html.
                                                Commission finds that:                                  Register on December 15, 2016 (81 FR                   *      *     *    *      *
                                                   A. The exemption is authorized by                    90871). No comments were received                         The NRC provides reasonable
                                                law;                                                    during the 30-day comment period.                      accommodation to individuals with
                                                   B. the exemption presents no undue                     The Commission has determined that                   disabilities where appropriate. If you
                                                risk to public health and safety;                       these amendments satisfy the criteria for              need a reasonable accommodation to
                                                   C. the exemption is consistent with                  categorical exclusion in accordance                    participate in these public meetings, or
                                                the common defense and security;                        with 10 CFR 51.22. Therefore, pursuant                 need this meeting notice or the
                                                   D. special circumstances are present                 to 10 CFR 51.22(b), no environmental                   transcript or other information from the
                                                in that the application of the rule in this             impact statement or environmental                      public meetings in another format (e.g.,
                                                circumstance is not necessary to serve                  assessment need be prepared for these                  braille, large print), please notify
                                                the underlying purpose of the rule;                     amendments.                                            Kimberly Meyer, NRC Disability
                                                   E. the special circumstances outweigh                                                                       Program Manager, at 301–287–0739, by
                                                any decrease in safety that may result                  IV. Conclusion
                                                                                                                                                               videophone at 240–428–3217, or by
                                                from the reduction in standardization                     Using the reasons set forth in the                   email at Kimberly.Meyer-Chambers@
                                                caused by the exemption; and                            combined safety evaluation, the staff                  nrc.gov. Determinations on requests for
                                                   F. the exemption will not result in a                granted the exemption and issued the                   reasonable accommodation will be
                                                significant decrease in the level of safety             amendment that the licensee requested                  made on a case-by-case basis.
                                                otherwise provided by the design.                       on letter dated November 18, 2016. The
                                                   2. Accordingly, the licensee is granted                                                                     *      *     *    *      *
                                                                                                        exemption and amendment were issued
                                                an exemption from the certified DCD                                                                               Members of the public may request to
                                                                                                        on February 28, 2017, as part of a
                                                Tier 1 information, with corresponding                                                                         receive this information electronically.
                                                                                                        combined package to the licensee
                                                changes to Appendix C of the Facility                                                                          If you would like to be added to the
                                                                                                        (ADAMS Accession No. ML17026A381).
                                                Combined Licenses as described in the                                                                          distribution, please contact the Nuclear
                                                                                                          Dated at Rockville, Maryland, this 30th day          Regulatory Commission, Office of the
                                                licensee’s request dated November 18,                   of May 2017.
                                                2016. This exemption is related to, and                                                                        Secretary, Washington, DC 20555 (301–
                                                                                                          For the Nuclear Regulatory Commission.               415–1969), or email
                                                necessary for the granting of License
                                                Amendment No. 61, which is being                        Jennifer Dixon-Herrity,                                Brenda.Akstulewicz@nrc.gov or
                                                issued concurrently with this                           Chief, Licensing Branch 4, Division of New             Patricia.Jimenez@nrc.gov.
                                                exemption.                                              Reactor Licensing, Office of New Reactors.               Dated: June 2, 2017.
                                                   3. As explained in Section 5.0 of the                [FR Doc. 2017–11803 Filed 6–6–17; 8:45 am]
                                                                                                                                                               Denise L. McGovern,
                                                NRC staff’s Safety Evaluation (ADAMS                    BILLING CODE 7590–01–P
                                                                                                                                                               Policy Coordinator, Office of the Secretary.
                                                Accession No. ML17026A479), this                                                                               [FR Doc. 2017–11880 Filed 6–5–17; 11:15 am]
                                                exemption meets the eligibility criteria
                                                                                                        NUCLEAR REGULATORY                                     BILLING CODE 7590–01–P
                                                for categorical exclusion set forth in 10
                                                CFR 51.22(c)(9). Therefore, pursuant to                 COMMISSION
                                                10 CFR 51.22(b), no environmental                       [NRC–2017–0001]
                                                impact statement or environmental                                                                              POSTAL REGULATORY COMMISSION
                                                assessment needs to be prepared in                      Sunshine Act Meeting Notice                            [Docket Nos. CP2015–55; MC2017–138 and
                                                connection with the issuance of the                                                                            CP2017–196]
                                                exemption.                                              DATES:Week of June 5, 2017.
                                                   4. This exemption is effective as of the             PLACE:Commissioners’ Conference                        New Postal Products
                                                date of its issuance.                                   Room, 11555 Rockville Pike, Rockville,                 AGENCY:   Postal Regulatory Commission.
                                                                                                        Maryland.
                                                III. License Amendment Request                                                                                 ACTION:   Notice.
                                                                                                        STATUS: Public.
                                                   By letter dated November 18, 2016                                                                           SUMMARY:   The Commission is noticing a
                                                (ADAMS Accession No. ML16323A335),                      Week of June 5—Tentative
                                                                                                                                                               recent Postal Service filing for the
                                                the licensee requested that the NRC                     Friday, June 09, 2017                                  Commission’s consideration concerning
                                                amend the COLs for VCSNS, Units 2                                                                              negotiated service agreements. This
                                                and 3, COLs NPF–93 and NPF–94. The                         11:30 a.m. Affirmation Session
                                                                                                        (Public Meeting) (Tentative)                           notice informs the public of the filing,
                                                proposed amendment is described in                                                                             invites public comment, and takes other
                                                                                                           Entergy Nuclear Operations, LLC &
                                                Section I of this Federal Register notice.                                                                     administrative steps.
                                                   The Commission has determined for                    Entergy Nuclear Operations, Inc. (James
                                                                                                        A. FitzPatrick Nuclear Power Plant),                   DATES: Comments are due: June 8, 2017.
                                                these amendments that the application
                                                complies with the standards and                         Request for Hearing on Requests for                    ADDRESSES: Submit comments
                                                requirements of the Atomic Energy Act                   Extension of Time to Comply with EA–                   electronically via the Commission’s
                                                of 1954, as amended (the Act), and the                  12–049, EA–12–051, and EA–13–109                       Filing Online system at http://
                                                Commission’s rules and regulations.                     (Tentative).                                           www.prc.gov. Those who cannot submit
                                                                                                        *     *     *    *     *                               comments electronically should contact
sradovich on DSK3GMQ082PROD with NOTICES




                                                The Commission has made appropriate
                                                findings as required by the Act and the                    The schedule for Commission                         the person identified in the FOR FURTHER
                                                                                                        meetings is subject to change on short                 INFORMATION CONTACT section by
                                                Commission’s rules and regulations in
                                                10 CFR Chapter I, which are set forth in                notice. For more information or to verify              telephone for advice on filing
                                                the license amendment.                                  the status of meetings, contact Denise                 alternatives.
                                                   A notice of consideration of issuance                McGovern at 301–415–0681 or via email                  FOR FURTHER INFORMATION CONTACT:
                                                of amendment to facility operating                      at Denise.McGovern@nrc.gov.                            David A. Trissell, General Counsel, at
                                                license or COL, as applicable, proposed                 *     *     *    *     *                               202–789–6820.


                                           VerDate Sep<11>2014   16:37 Jun 06, 2017   Jkt 241001   PO 00000   Frm 00099   Fmt 4703   Sfmt 4703   E:\FR\FM\07JNN1.SGM   07JNN1



Document Created: 2017-06-07 02:01:01
Document Modified: 2017-06-07 02:01:01
CategoryRegulatory Information
CollectionFederal Register
sudoc ClassAE 2.7:
GS 4.107:
AE 2.106:
PublisherOffice of the Federal Register, National Archives and Records Administration
SectionNotices
ActionExemption and combined license amendment; issuance.
DatesThe exemption and amendment were issued on February 28, 2017.
ContactRuth C. Reyes, Office of New Reactors, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001; telephone: 301-415-3249; email: [email protected]
FR Citation82 FR 26520 

2025 Federal Register | Disclaimer | Privacy Policy