83 FR 17174 - Notice of Preliminary Permit Application Accepted for Filing and Soliciting Comments, Motions To Intervene, and Competing Applications; Flat Canyon Hydro, LLC

DEPARTMENT OF ENERGY
Federal Energy Regulatory Commission

Federal Register Volume 83, Issue 75 (April 18, 2018)

Page Range17174-17174
FR Document2018-08078

Federal Register, Volume 83 Issue 75 (Wednesday, April 18, 2018)
[Federal Register Volume 83, Number 75 (Wednesday, April 18, 2018)]
[Notices]
[Page 17174]
From the Federal Register Online  [www.thefederalregister.org]
[FR Doc No: 2018-08078]


-----------------------------------------------------------------------

DEPARTMENT OF ENERGY

Federal Energy Regulatory Commission

[Project No. 14870-000]


Notice of Preliminary Permit Application Accepted for Filing and 
Soliciting Comments, Motions To Intervene, and Competing Applications; 
Flat Canyon Hydro, LLC

    On March 7, 2018, the Flat Canyon Hydro, LLC, filed an application 
for a preliminary permit, pursuant to section 4(f) of the Federal Power 
Act (FPA), proposing to study the feasibility of the Flat Canyon Pumped 
Storage Project (Flat Canyon Project or project) to be located in Flat 
Canyon, near the City of Elsinore, Sevier County, Utah. The sole 
purpose of a preliminary permit, if issued, is to grant the permit 
holder priority to file a license application during the permit term. A 
preliminary permit does not authorize the permit holder to perform any 
land-disturbing activities or otherwise enter upon lands or waters 
owned by others without the owners' express permission.
    The proposed project would be a closed-loop pumped storage 
hydropower facility that consists of the following: (1) A 37-acre upper 
reservoir having a total storage capacity of 1,800 acre-feet at a 
normal maximum operating elevation of 6,930 feet mean sea level (msl); 
(2) a 55-foot-high, 550-foot-long zoned earth/rockfill or concrete-
faced upper reservoir dam; (3) a 55-foot-high, 525-foot-long zoned 
earth/rockfill or concrete-faced second upper reservoir dam; (4) a 
1,350-foot-long, 15-foot-diameter low-pressure headrace tunnel either 
unlined or lined concrete-lined; (5) a 6,850-foot-long, 15-foot-
diameter high-pressure headrace tunnel lined with either concrete or 
steel; (6) a 220-foot-long, 60-foot-wide, 120-foot-high powerhouse 
housed in an underground cavern and accessed via a 2,600-foot-long, 18-
foot-diameter access tunnel, housing two variable-speed reversible 
pump/turbine-motor/generator units rated for 150 megawatts each at 
1,370 feet maximum gross head; (7) a 2,400-foot-long, 17.5-foot-
diameter tailrace tunnel lined with concrete; (8) a 37-acre lower 
reservoir having a total storage capacity 1,800 acre-feet at a normal 
maximum operating elevation of 5,630 feet msl; (9) a 75-foot-high, 850-
foot-long zoned earth/rockfill or concrete-faced lower reservoir dam; 
(10) a 13-mile-long, 230-kilovolt (kV) transmission line extending from 
the powerhouse that would follow an existing transmission corridor to 
the Sigurd Substation owned by Rocky Mountain Power, or, if possible, a 
direct connection to Rocky Mountain Power's Sigurd-Red Butte No. 2 345-
kV line adjacent to the project (the point of interconnection); and 
(11) appurtenant facilities. The estimated annual generation of the 
Flat Canyon Project would be 525.6 gigawatt-hours.
    Applicant Contact: Matthew Shapiro, CEO, Gridflex Energy, LLC, 1210 
W Franklin St, Ste. 2, Boise, Idaho 83702; phone: (208) 246-9925.
    FERC Contact: Kyle Olcott; phone: (202) 502-8963.
    Deadline for filing comments, motions to intervene, competing 
applications (without notices of intent), or notices of intent to file 
competing applications: 60 days from the issuance of this notice. 
Competing applications and notices of intent must meet the requirements 
of 18 CFR 4.36.
    The Commission strongly encourages electronic filing. Please file 
comments, motions to intervene, notices of intent, and competing 
applications using the Commission's eFiling system at http://www.ferc.gov/docs-filing/efiling.asp. Commenters can submit brief 
comments up to 6,000 characters, without prior registration, using the 
eComment system at http://www.ferc.gov/docs-filing/ecomment.asp. You 
must include your name and contact information at the end of your 
comments. For assistance, please contact FERC Online Support at 
[email protected], (866) 208-3676 (toll free), or (202) 502-
8659 (TTY). In lieu of electronic filing, please send a paper copy to: 
Secretary, Federal Energy Regulatory Commission, 888 First Street NE, 
Washington, DC 20426. The first page of any filing should include 
docket number P-14870-000.
    More information about this project, including a copy of the 
application, can be viewed or printed on the eLibrary link of 
Commission's website at http://www.ferc.gov/docs-filing/elibrary.asp. 
Enter the docket number (P-14870) in the docket number field to access 
the document. For assistance, contact FERC Online Support.

    Dated: April 12, 2018. .
Nathaniel J. Davis, Sr.,
Deputy Secretary.
[FR Doc. 2018-08078 Filed 4-17-18; 8:45 am]
 BILLING CODE 6717-01-P


Current View
CategoryRegulatory Information
CollectionFederal Register
sudoc ClassAE 2.7:
GS 4.107:
AE 2.106:
PublisherOffice of the Federal Register, National Archives and Records Administration
SectionNotices
FR Citation83 FR 17174 

2024 Federal Register | Disclaimer | Privacy Policy
USC | CFR | eCFR