DEPARTMENT OF LABOR
Mine Safety and Health Administration

Federal Register Volume 83, Issue 14 (January 22, 2018)

Page Range3027-3031
FR Document2018-01008

This notice is a summary of petitions for modification submitted to the Mine Safety and Health Administration (MSHA) by the parties listed below.

Federal Register, Volume 83 Issue 14 (Monday, January 22, 2018)
[Federal Register Volume 83, Number 14 (Monday, January 22, 2018)]
[Notices]
[Pages 3027-3031]
From the Federal Register Online  [www.thefederalregister.org]
[FR Doc No: 2018-01008]


=======================================================================
-----------------------------------------------------------------------

DEPARTMENT OF LABOR

Mine Safety and Health Administration


Petitions for Modification of Application of Existing Mandatory 
Safety Standards

AGENCY: Mine Safety and Health Administration, Labor.

ACTION: Notice.

-----------------------------------------------------------------------

SUMMARY: This notice is a summary of petitions for modification 
submitted to the Mine Safety and Health Administration (MSHA) by the 
parties listed below.

DATES: All comments on the petitions must be received by MSHA's Office 
of Standards, Regulations, and Variances on or before February 21, 
2018.

ADDRESSES: You may submit your comments, identified by ``docket 
number'' on the subject line, by any of the following methods:
    1. Electronic Mail: [email protected]. Include the docket 
number of the petition in the subject line of the message.
    2. Facsimile: 202-693-9441.
    3. Regular Mail or Hand Delivery: MSHA, Office of Standards, 
Regulations, and Variances, 201 12th Street South, Suite 4E401, 
Arlington, Virginia 22202-5452, Attention: Sheila McConnell, Director, 
Office of Standards, Regulations, and Variances. Persons delivering 
documents are required to check in at the receptionist's desk in Suite 
4E401. Individuals may inspect copies of the petition and comments 
during normal business hours at the address listed above.
    MSHA will consider only comments postmarked by the U.S. Postal 
Service or proof of delivery from another delivery service such as UPS 
or Federal Express on or before the deadline for comments.

FOR FURTHER INFORMATION CONTACT: Barbara Barron, Office of Standards, 
Regulations, and Variances at 202-693-9447 (Voice), 
[email protected] (Email), or 202-693-9441 (Facsimile). [These are 
not toll-free numbers.]

SUPPLEMENTARY INFORMATION: Section 101(c) of the Federal Mine Safety 
and Health Act of 1977 and Title 30 of the Code of Federal Regulations 
Part 44 govern the application, processing, and disposition of 
petitions for modification.

I. Background

    Section 101(c) of the Federal Mine Safety and Health Act of 1977 
(Mine Act) allows the mine operator or representative of miners to file 
a petition to modify the application of any mandatory safety standard 
to a coal or other mine if the Secretary of Labor (Secretary) 
determines that:
    1. An alternative method of achieving the result of such standard 
exists which will at all times guarantee no less than the same measure 
of protection afforded the miners of such mine by such standard; or
    2. That the application of such standard to such mine will result 
in a diminution of safety to the miners in such mine.
    In addition, the regulations at 30 CFR 44.10 and 44.11 establish 
the requirements and procedures for filing petitions for modification.

II. Petitions for Modification

    Docket Number: M-2017-030-C.
    Petitioner: Bronco Utah Operations, LLC, P.O. Box 527, Emery, Utah 
84522.
    Mine: Emery Mine, MSHA I.D. No. 42-00079, located in Emery County, 
Utah.
    Regulation Affected: 30 CFR 75.500(d) (Permissible electric 
equipment).
    Modification Request: The petitioner requests a modification of the 
existing standard to permit the alternative method of compliance to 
allow the use of nonpermissible low-voltage or battery-powered 
electronic testing or diagnostic equipment in or inby the last open 
crosscut.
    The petitioner states that:
    (1) The use of nonpermissible low-voltage or battery-powered 
electronic testing and diagnostic equipment will be limited to laptop 
computers; oscilloscopes; vibration analysis machines; cable fault 
detectors; point temperature probes; infrared temperature devices; 
voltage, current, and power measurement recorders; pressure and flow 
measurement devices; signal analyzer devices; ultrasonic thickness 
gauges; electronic tachometers; and nonpermissible surveying equipment. 
Other testing and diagnostic equipment may be used if approved in 
advance by the MSHA District Office.
    (2) Nonpermissible electronic testing and diagnostic equipment will 
be used only when equivalent permissible equipment does not exist.
    (3) All other test and diagnostic equipment used in or inby the 
last open crosscut will be permissible.
    (4) All nonpermissible electronic testing and diagnostic equipment 
used in or inby the last open crosscut will be examined by a qualified 
person, as defined in 30 CFR 75.153, prior to being used to ensure the 
equipment is being maintained in safe operating condition. These 
examinations results will be recorded in the weekly examination of 
electrical equipment book and will be made available to MSHA and the 
miners at the mine.
    (5) A qualified person, as defined in 30 CFR 75.151, will 
continuously monitor for methane immediately before and during the use 
of nonpermissible electronic testing and diagnostic equipment in or 
inby the last open crosscut. The results of such examination(s) will be 
recorded as a special examination in the on-shift examination record 
books immediately after the shift on which the examination(s) were 
performed.
    (6) Nonpermissible electronic testing and diagnostic equipment will 
not be used if methane is detected in concentrations at or above 1.0 
percent. When a 1.0 percent or more methane concentration is detected 
while the nonpermissible electronic equipment is being used, the 
equipment will be deenergized immediately and withdrawn to outby the 
last open crosscut.
    (7) All hand-held methane detectors will be MSHA-approved and 
maintained in permissible and proper operating condition as defined in 
30 CFR 75.320.
    (8) Except for the time necessary to troubleshoot under actual 
mining conditions, coal production in the miner section will cease. 
However, coal may remain in or on the equipment in order to test and 
diagnose the equipment under ``load.''
    (9) Nonpermissible electronic testing and diagnostic equipment will 
not be used to test equipment when float coal dust is in suspension.
    (10) All electronic testing and diagnostic equipment will be used 
in accordance with the manufacturer's recommended safe use practices.
    (11) Qualified personnel engaged in the use of electronic testing 
and diagnostic equipment will be properly trained to recognize the 
hazards and limitations associated with use of the electronic testing 
and diagnostic equipment.
    (12) The petitioner will notify MSHA before using nonpermissible 
electronic

[[Page 3028]]

testing and diagnostic equipment in or inby the last open crosscut. The 
notice will advise MSHA when any nonpermissible electronic testing and 
diagnostic equipment is put in service and will give MSHA the 
opportunity to inspect such equipment before being used.
    (13) Within 60 days after the proposed decision and order (PDO) 
becomes final, the petitioner will submit proposed revisions for its 
approved 30 CFR part 48 training plan to the District Manager. These 
revisions will specify initial and refresher training regarding the 
terms and conditions of the PDO.
    The petitioner asserts that application of the existing standard 
will result in a diminution of safety to the miners and that the 
proposed alternative method will at all times guarantee no less than 
the same measure of protection afforded by the existing standard.

    Docket Number: M-2017-031-C.
    Petitioner: M & D Anthracite Coal Company, 2030 East Center Street, 
Tremont, Pennsylvania 17981.
    Mine: Slope #1 Mine, MSHA I.D. No. 36-09976, located in Schuylkill 
County, Pennsylvania.
    Regulation Affected: 30 CFR 49.2(b) (Availability of mine rescue 
teams).
    Modification Request: The petitioner requests a modification of the 
existing standard to permit the reduction of two mine rescue teams with 
five members and one alternate each to two mine rescue teams of three 
members each with one alternative for either team.
    The petitioner states that:
    (1) The underground mine is a small mine and there is hardly enough 
physical room to accommodate more than three or four miners in the 
working places. An attempt to utilize five or more rescue team members 
in the mine's confined working places would result in a diminution of 
safety to both the miners at the mine and members of the rescue team.
    (2) Records of Mine Emergency responses over the last 20 years 
indicate that rescue and recovery operations conducted by Anthracite 
Underground Rescue, Inc. (AUGR) have never utilized more than one team. 
In addition, when one rescue team was utilized there were no more than 
three rescue team members traveling to a working place simultaneously.
    (3) Employment in underground anthracite mines has decreased 
substantially and the ratio of mine rescue teams to underground miners 
has correspondingly been reduced. The loss of the underground work 
force dramatically reduces the pool of qualified people available to 
fill mine rescue positions.
    (4) Pennsylvania Deep Mine Safety presently has four deep mine 
inspectors that have deep mine rescue training and are pledged to 
assist if required in an emergency. In addition, the surrounding small 
mines have always provided assistance during mine emergencies.
    The petitioner asserts that the proposed alternative method will 
provide the same measure of protection afforded the miners under the 
existing standard.

    Docket Number: M-2017-032-C.
    Petitioner: M & D Anthracite Coal Company, 2030 East Center Street, 
Tremont, Pennsylvania 17981.
    Mine: Slope #1 Mine, MSHA I.D. No. 36-09976, located in Schuylkill 
County, Pennsylvania.
    Regulation Affected: 30 CFR 49.6(a)(1) and (a)(5) (Equipment 
maintenance requirements).
    Modification Request: The petitioner requests a modification of the 
existing standard to permit the reduction of twelve self-contained 
oxygen breathing apparatus, to eight self-contained apparatus and the 
reduction of twelve permissible cap lamps and charging rack to eight 
permissible cap lamps and charging rack.
    The petitioner states that:
    (1) A petition for modification of 30 CFR 49.2(b) allowing the 
reduction of two rescue teams with five members and one alternate each 
to two rescue teams of three members each with one alternate has been 
granted to all operating anthracite coal mines.
    (2) Eight self-contained breathing apparatus and eight permissible 
cap lamps are sufficient to supply the seven members of the rescue 
team.
    The petitioner asserts that the proposed alternative method will at 
all times guarantee no less than the same measure of protection 
afforded the miners under the existing standard.

    Docket Number: M-2017-033-C.
    Petitioner: M & D Anthracite Coal Company, 2030 East Center Street, 
Tremont, Pennsylvania 17981.
    Mine: Slope #1 Mine, MSHA I.D. No. 36-09976, located in Schuylkill 
County, Pennsylvania.
    Regulation Affected: 30 CFR 75.311(b)(2) and (b)(3) (Main mine fan 
operation).
    Modification Request: The petitioner requests a modification of the 
existing standard to permit the electrical circuits entering the 
underground mine to remain energized to the mine's pumps, while the 
main fan has been shut down during idle shifts when no miners are 
working underground.
    The petitioner states that:
    (1) The mine requires pumping water from the sump area of the 
intake haulage slope below the active gangway level workings 
intermittently and for different periods of time on a daily basis. 
During the wet season from late winter to early summer, the pumps are 
often required to operate for extended periods of time to keep the mine 
from flooding.
    (2) Most anthracite mines work only one shift per day, 5-6 days per 
week during the colder months when coal sales are greatest, and may 
only work 2-3 days per week during the warmer months because of lower 
coal sales.
    (3) The vast majority of underground anthracite mines are small, 
employ 5 or less miners underground, have very low daily coal 
production of less than 25 tons, and have never encountered a 
measurable quantity of methane during the life of the mine.
    (4) Methane liberation in the few underground mines with a history 
of liberation occurs only when coal is shot from the solid and is 
dissipated by face ventilation shortly thereafter.
    (5) Underground anthracite miners are significantly affected by 
natural ventilation that continues after the mine fan has been 
intentionally stopped during idle periods.
    (6) Accumulations of methane, in those underground mines with a 
history of liberation, are historically found in chutes and breasts 
(entries driven up the pitch) and are not yet connected to the adjacent 
return entry. These entries are not affected by the natural ventilation 
air currents.
    (7) The primary method of face ventilation utilized in underground 
anthracite mines is compressed air movers with approved tubing in the 
working place. They are shut off prior to the miners exiting the mine 
at the end of the shift and prior to the stoppage of the main fan for 
the idle shifts. Therefore, potential accumulation of methane in the 
working face is unlikely to be affected by natural ventilation 
currents.
    (8) The mine's pumping system typically consists of a submersible 
pump located below the water level in the sump and a centrifugal pump 
located in the intake haulage slope above the active gangway level. The 
pumps are started and shut off by a set of switches or electrodes 
located in the sump. The switch/electrode located at the highest 
elevation in the sump will start the pumps when the water depth 
increases to a pre-determined level to protect the active gangway level 
from flooding. The pumps will continue to operate until the water level 
depth decreases to the elevation of the lower switch/electrode.

[[Page 3029]]

    (9) Compliance with 30 CFR 75.311 through the continuous operation 
of the main mine fan when pumps are energized would result in a 
diminution of safety to the miners. During the colder months, the wet 
conditions present in the intake haulage slope will result in freezing 
and accumulations of ice creating a hazard to the miners riding the 
slope conveyance and to those miners who must manually chip away the 
ice in the pitching slope thereby increasing a fall hazard. The amount 
of ice accumulations during a single shift of production is usually 
minimal and can be melted during the idle shifts, with the main fan 
off, as the natural ventilating air current is warmed by the higher 
underground temperatures and carried through slope.
    (10) The mine operator proposes to initiate the following 
alternatives to ensure the safety of the miners:
    (a) The examiner will determine whether the pumps are operating and 
if the natural ventilation air current is moving in the proper 
direction prior to energizing the main mine fan and before starting the 
required pre-shift examination.
    (b) In the cases where the pumps are not operating when the 
examiner arrives, the examiner will deenergize the pump circuits before 
starting the main mine fan and will allow the fan to operate for 30 
minutes prior to entering the mine to conduct the pre-shift 
examination.
    (c) During the pre-shift examination, when no accumulation of 
methane is found in the vicinity of the pumps, the pump circuits may be 
energized before the miners travel underground.
    (d) In those cases where the pumps are found to be already in 
operation because of high water levels and when the natural ventilating 
currents are moving in the proper direction, the main mine fan will be 
started and run for 30 minutes before entering the mine to conduct a 
pre-shift examination. Examination of the mine pump installation will 
be completed prior to entering the active gangway level working and 
before continuing the pre-shift examination.
    The petitioner asserts that the proposed alternative method will 
provide no less than the same measure of protection afforded the miners 
under the existing standard.

    Docket Number: M-2017-034-C.
    Petitioner: M & D Anthracite Coal Company, 2030 East Center Street, 
Tremont, Pennsylvania 17981.
    Mine: Slope #1 Mine, MSHA I.D. No. 36-09976, located in Schuylkill 
County, Pennsylvania.
    Regulation Affected: 30 CFR 75.335 (Seal strengths, design 
applications, and installation).
    Modification Request: The petitioner requests a modification of the 
existing standard to permit alternative methods of construction 
employing wooden material of moderate size and weight due to the 
difficulty in accessing previously driven headings and breasts 
containing the inaccessible abandoned workings through the use of 
homemade ladders. Additionally, a design criterion in the 10-psi range 
should be accepted due to the non-explosibility of anthracite coal dust 
and minimal potential for either an accumulation of methane in 
previously mined pitching veins or an ignition source in the gob area, 
and that seals installed in pairs permit the water trap to be installed 
only in the gangway seal (lowest elevation) and sampling tube in the 
monkey (higher elevation) seal.
    The petitioner states that:
    (1) The required transportation of solid concrete blocks or 
equivalent materials manually on ladders on pitching anthracite veins 
will expose miners to greater hazards such as falling, being struck by 
falling materials, or resulting strains or sprains due to the weight of 
the materials.
    (2) No evidence of ignition in accessible abandoned anthracite 
workings has been found to date.
    (3) In veins pitching greater than 45 degrees, the weight of the 
seal is transferred to the low side rib (coal).
    (4) Irregularly shaped anthracite openings would require 
substantial cutting of rectangular blocks to ensure proper tie-in to 
hitches in the top rock, bottom rock, and low side coal rib.
    (5) Concrete block and mortar construction for openings parallel to 
the pitching vein would be almost impossible to construct and subject 
to failure by its own weight.
    (6) Isolation of inaccessible abandoned workings from an active 
section will permit natural venting of any potential methane build-up 
through surface breeches, and the mine has not experienced measurable 
liberation of methane to-date.
    The petitioner asserts that the proposed alternative method will 
provide no less than the same measure of protection afforded the miners 
under the existing standard.

    Docket Number: M-2017-035-C.
    Petitioner: M & D Anthracite Coal Company, 2030 East Center Street, 
Tremont, Pennsylvania 17981.
    Mine: Slope #1 Mine, MSHA I.D. No. 36-09976, located in Schuylkill 
County, Pennsylvania.
    Regulation Affected: 30 CFR 75.1002(a) (Installation of electric 
equipment and conductors; permissibility).
    Modification Request: The petitioner requests a modification of the 
existing standard to permit the use of nonpermissible electric 
equipment within 150 feet of the pillar line to include drags and 
battery locomotives due in part to the method of mining used in 
pitching anthracite mines and the alternative hourly evaluation of the 
mine air quality for methane during operation with one of the gas test 
results to be recorded in the on-shift examination record. Petitioner 
also proposes to suspend equipment operation anytime methane 
concentration at the equipment reaches 0.5 percent either during 
operation or when found during a pre-shift examination.
    The petitioner states that:
    (1) The equipment will be operated in the working section's only 
intake entry (gangway) which is regularly traveled and examined.
    (2) The use of drags on less than moderate pitching veins (less 
than 20 degrees pitch) is the only practical system of mining in use.
    (3) Permissible drags are not commercially available and, due in 
part to their small size, permissible locomotives are not commercially 
available.
    (4) As result of low daily production rates and full timbering 
support, in-rushes of methane due to massive pillar falls are unlikely 
to occur.
    (5) Recovery of the pillars above the first miner heading is 
usually accomplished on the advance within 150 feet of the section 
intake (gangway) and the remaining minable pillars recovered from the 
deepest point of penetration outby.
    (6) The 5,000 cfm of required intake air flow is measured just 
outby the nonpermissible equipment with the ventilating air passing 
over the equipment to ventilate the pillar being mined.
    (7) The nonpermissible electrical equipment is attended during 
operation and either power to the unit will be deenergized at the 
intersection of the working gangway and intake slope or the equipment 
will be moved to that area when production ceases, thereby, minimizing 
any ignition potential from the pillar recovery area.
    (8) Where more than one active line of pillar breast recovery 
exists, the locomotive may travel to a point just outby the deepest 
active chute/breast (room) workings or last open crosscut in a 
developing set of entries.

[[Page 3030]]

    The petitioner asserts that the proposed alternative method will 
provide no less than the same measure of protection afforded the miners 
under the existing standard.

    Docket Number: M-2017-037-C.
    Petitioner: M & D Anthracite Coal Company, 2030 East Center Street, 
Tremont, Pennsylvania 17981.
    Mine: Slope #1 Mine, MSHA I.D. No. 36-09976, located in Schuylkill 
County, Pennsylvania.
    Regulation Affected: 30 CFR 75.1200(d) and (i) (Mine map).
    Modification Request: The petitioner requests a modification of the 
existing standard to permit the substitution of cross-sections in lieu 
of contour lines through the intake slope, at locations of rock tunnel 
connections between veins, and at 1,000 feet intervals of advance from 
the intake slope and to limit the required mapping of mine workings 
above and below to those present within 100 feet of the vein(s) being 
mined unless these veins are interconnected to other veins beyond the 
100 feet limit, through rock tunnels.
    The petitioner states that:
    (1) Due to steep pitch encountered in mining anthracite coal veins, 
contours provide no useful information and their presence would make 
portions of the map illegible.
    (2) The vast majority of current underground anthracite mining 
involves either second mining of remnant pillars from previous mining/
mine operators or the mining of veins of lower quality in proximity to 
inaccessible and frequently flooded abandoned mine workings which may 
or may not be mapped.
    (3) All mapping for mines above and below will be researched by a 
contract engineer for the presence of interconnecting rock tunnels 
between veins in relation to the mine and a hazard analysis done when 
mapping indicates the presence of known or potentially flooded 
workings.
    (4) Mine workings found to exist beyond 100 feet from the mine, 
when no rock tunnel connections are found, will be recognized as 
presenting no hazard to the mine due to the pitch of the vein and rock 
separation between.
    (5) Additionally, the mine workings above and below are usually 
inactive and abandoned and therefore, not subject to changes during the 
life of the mine.
    (6) Where evidence indicates prior mining was conducted on a vein 
above or below and research exhausts the availability of mine mapping, 
the vein will be considered to be mined and flooded and appropriate 
precautions taken, as required by 30 CFR 75.388, where possible.
    (7) Where potential hazards exist and in-mine drilling capabilities 
limit penetration, surface boreholes may be used to intercept the 
workings and results analyzed prior to the beginning of mining in the 
affected area.
    The petitioner asserts that the proposed alternative method will 
provide no less than the same measure of protection afforded the miners 
under the existing standard.

    Docket Number: M-2017-038-C.
    Petitioner: M & D Anthracite Coal Company, 2030 East Center Street, 
Tremont, Pennsylvania 17981.
    Mine: Slope #1 Mine, MSHA I.D. No. 36-09976, located in Schuylkill 
County, Pennsylvania.
    Regulation Affected: 30 CFR 75.1202-1(a) (Temporary notations, 
revisions and supplements).
    Modification Request: The petitioner requests a modification of the 
existing standard to permit the required interval of survey to be on an 
annual basis from the initial survey in lieu of the current interval of 
not more than 6 months.
    The petitioner proposes to continue to update the mine map by hand 
notations on a daily basis and conduct subsequent surveys prior to 
commencing retreat mining, and when either a drilling program is 
required by 30 CFR 75.388 or a plan for mining into inaccessible areas 
is required by 30 CFR 75.389.
    The petitioner states that:
    (1) The low production and slow rate of advance in anthracite 
mining make surveying on 6-month intervals impractical. The mine 
operates using non-mechanized, hand-loading mining methods. In most 
cases, annual development is frequently limited to less than 500 feet 
of gangway advance with associated up-pitch development.
    (2) Development above the active gangway is designed to mine into 
the level above at designated intervals thereby maintaining sufficient 
control between both surveyed gangways.
    (3) The available engineering/surveyor resources are limited in the 
anthracite coal fields. Surveying on an annual basis is difficult to 
achieve with four individual contractors currently available.
    The petitioner asserts that the proposed alternative method will 
provide no less than the same measure of protection afforded the miners 
under the existing standard.

    Docket Number: M-2017-039-C.
    Petitioner: M & D Anthracite Coal Company, 2030 East Center Street, 
Tremont, Pennsylvania 17981.
    Mine: Slope #1 Mine, MSHA I.D. No. 36-09976, located in Schuylkill 
County, Pennsylvania.
    Regulation Affected: 30 CFR 75.1400(c) (Hoisting equipment; 
general).
    Modification Request: The petitioner requests a modification of the 
existing standard to permit the gunboat to transport persons without 
safety catches or other no less effective devices because to date, no 
such safety catch or device is available for steeply pitching and 
undulating slopes with numerous curves and knuckles present in the main 
haulage slopes of Anthracite mines, that range in length from 30 to 
4200 feet and vary in pitch from 12 degrees and 75 degrees.
    The petitioner states that:
    (1) A functional safety catch has not been developed. Makeshift 
devices, if installed, could be activated on knuckles and curves when 
no emergency exists causing a tumbling effect on the conveyance which 
would increase rather than decrease the hazard to miners.
    (2) As an alternative, the petitioner proposes to operate the man 
cage or steel gunboat with secondary safety connections securely 
fastened around the gunboat and to the hoisting rope above the main 
connecting device and use hoisting ropes having a factor of safety in 
excess of the 4 to 8 to 1 as suggested in the American Standards 
Specifications for Use of Wire Ropes for Mines.
    The petitioner asserts that the proposed alternative method will 
provide no less than the same measure of protection afforded the miners 
under the existing standard.

    Docket Number: M-2017-040-C.
    Petitioner: Mountain Coal Company, LLC, 5174 Hwy. 133, Somerset, CO 
81434.
    Mine: West Elk Mine, MSHA I.D. No. 05-03672, located in Gunnison 
County, Colorado.
    Regulation Affected: 30 CFR 75.364(b)(2) (Weekly examination).
    Modification Request: The petitioner requests a modification of the 
existing standard that requires at least one entry of each return air 
course to be traveled and examined in its entirety at least every 7 
days by a certified person. The petitioner proposes to establish 
multiple inlet and outlet evaluation points to measure and evaluate at 
least every 7 days the air quality, air quantity, and air direction of 
all air entering and leaving the Sly Gulch South Mains Return in lieu 
of traveling one of the affected entries. The petitioner states that:
    (1) Multiple roof falls and floor heave within the proposed 
evaluation area limits the entries that can be traveled by the weekly 
examiner. Some of the

[[Page 3031]]

traveled entries require the weekly examiner to crawl on his hands and 
knees, preventing quick egress if necessary.
    (2) All air entering and leaving the affected area can be measured 
and evaluated safely from the proposed inlet and outlet evaluation 
points shown on the drawing attached to this petition. Access to the 
proposed inlet and outlet evaluation points is not hindered by roof 
falls or excessive floor heave, allowing quick egress if necessary.
    (3) There are no seals or electrical installations within the 
proposed evaluation area that must be examined.
    (4) In lieu of traveling one of the return entries in the proposed 
evaluation area, at least every 7 days, a certified person will:
    (a) Measure the air quantity at each inlet and outlet evaluation 
point. If the combined air quantity at the outlet evaluation points 
differs by more than 20 percent from the combined air quantity at the 
inlet evaluation points, ventilation controls surrounding the affected 
area will be examined from the outby side and corrective measures will 
be implemented to repair the affected ventilation controls to restore 
the differential air quantities to within 20 percent.
    (b) Measure the air quality at each inlet and outlet evaluation 
point. Both the methane and oxygen concentrations will be measured. 
Methane concentrations at the inlet and outlet evaluation points will 
be a minimum of 19.5 percent.
    (c) Verify the proper air direction as indicated on the drawing at 
each inlet and outlet evaluation point.
    (d) Record the air quantity, air quality, and a notation of proper 
air direction at each inlet and outlet evaluation point in the weekly 
examination book.
    The petitioner asserts that the proposed alternative method will at 
all times guarantee no less than the same measure of protection as that 
afforded by the existing standard and that traveling one of the 
affected entries results in a diminution of safety.

Sheila McConnell,
Director, Office of Standards, Regulations, and Variances.
[FR Doc. 2018-01008 Filed 1-19-18; 8:45 am]
 BILLING CODE 4520-43-P



                                                                             Federal Register / Vol. 83, No. 14 / Monday, January 22, 2018 / Notices                                             3027

                                               ‘‘Libya III program’’), involving claims                SUPPLEMENTARY INFORMATION:     Section                 only when equivalent permissible
                                               of United States nationals against the                  101(c) of the Federal Mine Safety and                  equipment does not exist.
                                               Government of Libya that were settled                   Health Act of 1977 and Title 30 of the                    (3) All other test and diagnostic
                                               under the ‘‘Claims Settlement                           Code of Federal Regulations Part 44                    equipment used in or inby the last open
                                               Agreement Between the United States of                  govern the application, processing, and                crosscut will be permissible.
                                               America and the Great Socialist People’s                disposition of petitions for modification.                (4) All nonpermissible electronic
                                               Libyan Arab Jamahiriya,’’ dated August                                                                         testing and diagnostic equipment used
                                                                                                       I. Background                                          in or inby the last open crosscut will be
                                               14, 2008.
                                                                                                         Section 101(c) of the Federal Mine                   examined by a qualified person, as
                                               Brian M. Simkin,                                                                                               defined in 30 CFR 75.153, prior to being
                                                                                                       Safety and Health Act of 1977 (Mine
                                               Chief Counsel.                                          Act) allows the mine operator or                       used to ensure the equipment is being
                                               [FR Doc. 2018–01047 Filed 1–19–18; 8:45 am]             representative of miners to file a                     maintained in safe operating condition.
                                               BILLING CODE 4410–01–P                                  petition to modify the application of any              These examinations results will be
                                                                                                       mandatory safety standard to a coal or                 recorded in the weekly examination of
                                                                                                       other mine if the Secretary of Labor                   electrical equipment book and will be
                                               DEPARTMENT OF LABOR                                     (Secretary) determines that:                           made available to MSHA and the miners
                                                                                                         1. An alternative method of achieving                at the mine.
                                               Mine Safety and Health Administration                   the result of such standard exists which                  (5) A qualified person, as defined in
                                                                                                       will at all times guarantee no less than               30 CFR 75.151, will continuously
                                               Petitions for Modification of                                                                                  monitor for methane immediately before
                                                                                                       the same measure of protection afforded
                                               Application of Existing Mandatory                                                                              and during the use of nonpermissible
                                                                                                       the miners of such mine by such
                                               Safety Standards                                                                                               electronic testing and diagnostic
                                                                                                       standard; or
                                               AGENCY: Mine Safety and Health                            2. That the application of such                      equipment in or inby the last open
                                               Administration, Labor.                                  standard to such mine will result in a                 crosscut. The results of such
                                               ACTION: Notice.                                         diminution of safety to the miners in                  examination(s) will be recorded as a
                                                                                                       such mine.                                             special examination in the on-shift
                                               SUMMARY:    This notice is a summary of                   In addition, the regulations at 30 CFR               examination record books immediately
                                               petitions for modification submitted to                 44.10 and 44.11 establish the                          after the shift on which the
                                               the Mine Safety and Health                              requirements and procedures for filing                 examination(s) were performed.
                                               Administration (MSHA) by the parties                    petitions for modification.                               (6) Nonpermissible electronic testing
                                               listed below.                                                                                                  and diagnostic equipment will not be
                                                                                                       II. Petitions for Modification                         used if methane is detected in
                                               DATES: All comments on the petitions
                                               must be received by MSHA’s Office of                      Docket Number: M–2017–030–C.                         concentrations at or above 1.0 percent.
                                               Standards, Regulations, and Variances                     Petitioner: Bronco Utah Operations,                  When a 1.0 percent or more methane
                                               on or before February 21, 2018.                         LLC, P.O. Box 527, Emery, Utah 84522.                  concentration is detected while the
                                                                                                         Mine: Emery Mine, MSHA I.D. No.                      nonpermissible electronic equipment is
                                               ADDRESSES: You may submit your
                                                                                                       42–00079, located in Emery County,                     being used, the equipment will be
                                               comments, identified by ‘‘docket
                                                                                                       Utah.                                                  deenergized immediately and
                                               number’’ on the subject line, by any of
                                                                                                         Regulation Affected: 30 CFR 75.500(d)                withdrawn to outby the last open
                                               the following methods:
                                                                                                       (Permissible electric equipment).                      crosscut.
                                                  1. Electronic Mail: zzMSHA-                                                                                    (7) All hand-held methane detectors
                                               comments@dol.gov. Include the docket                      Modification Request: The petitioner
                                                                                                                                                              will be MSHA-approved and
                                               number of the petition in the subject                   requests a modification of the existing
                                                                                                                                                              maintained in permissible and proper
                                               line of the message.                                    standard to permit the alternative
                                                                                                                                                              operating condition as defined in 30
                                                  2. Facsimile: 202–693–9441.                          method of compliance to allow the use
                                                                                                                                                              CFR 75.320.
                                                  3. Regular Mail or Hand Delivery:                    of nonpermissible low-voltage or                          (8) Except for the time necessary to
                                               MSHA, Office of Standards,                              battery-powered electronic testing or                  troubleshoot under actual mining
                                               Regulations, and Variances, 201 12th                    diagnostic equipment in or inby the last               conditions, coal production in the miner
                                               Street South, Suite 4E401, Arlington,                   open crosscut.                                         section will cease. However, coal may
                                               Virginia 22202–5452, Attention: Sheila                    The petitioner states that:                          remain in or on the equipment in order
                                               McConnell, Director, Office of                            (1) The use of nonpermissible low-                   to test and diagnose the equipment
                                               Standards, Regulations, and Variances.                  voltage or battery-powered electronic                  under ‘‘load.’’
                                               Persons delivering documents are                        testing and diagnostic equipment will                     (9) Nonpermissible electronic testing
                                               required to check in at the receptionist’s              be limited to laptop computers;                        and diagnostic equipment will not be
                                               desk in Suite 4E401. Individuals may                    oscilloscopes; vibration analysis                      used to test equipment when float coal
                                               inspect copies of the petition and                      machines; cable fault detectors; point                 dust is in suspension.
                                               comments during normal business                         temperature probes; infrared                              (10) All electronic testing and
                                               hours at the address listed above.                      temperature devices; voltage, current,                 diagnostic equipment will be used in
                                                  MSHA will consider only comments                     and power measurement recorders;                       accordance with the manufacturer’s
                                               postmarked by the U.S. Postal Service or                pressure and flow measurement devices;                 recommended safe use practices.
                                               proof of delivery from another delivery                 signal analyzer devices; ultrasonic                       (11) Qualified personnel engaged in
                                               service such as UPS or Federal Express                  thickness gauges; electronic                           the use of electronic testing and
ethrower on DSK3G9T082PROD with NOTICES




                                               on or before the deadline for comments.                 tachometers; and nonpermissible                        diagnostic equipment will be properly
                                               FOR FURTHER INFORMATION CONTACT:                        surveying equipment. Other testing and                 trained to recognize the hazards and
                                               Barbara Barron, Office of Standards,                    diagnostic equipment may be used if                    limitations associated with use of the
                                               Regulations, and Variances at 202–693–                  approved in advance by the MSHA                        electronic testing and diagnostic
                                               9447 (Voice), barron.barbara@dol.gov                    District Office.                                       equipment.
                                               (Email), or 202–693–9441 (Facsimile).                     (2) Nonpermissible electronic testing                   (12) The petitioner will notify MSHA
                                               [These are not toll-free numbers.]                      and diagnostic equipment will be used                  before using nonpermissible electronic


                                          VerDate Sep<11>2014   19:00 Jan 19, 2018   Jkt 244001   PO 00000   Frm 00070   Fmt 4703   Sfmt 4703   E:\FR\FM\22JAN1.SGM   22JAN1


                                               3028                          Federal Register / Vol. 83, No. 14 / Monday, January 22, 2018 / Notices

                                               testing and diagnostic equipment in or                     (4) Pennsylvania Deep Mine Safety                   haulage slope below the active gangway
                                               inby the last open crosscut. The notice                 presently has four deep mine inspectors                level workings intermittently and for
                                               will advise MSHA when any                               that have deep mine rescue training and                different periods of time on a daily
                                               nonpermissible electronic testing and                   are pledged to assist if required in an                basis. During the wet season from late
                                               diagnostic equipment is put in service                  emergency. In addition, the surrounding                winter to early summer, the pumps are
                                               and will give MSHA the opportunity to                   small mines have always provided                       often required to operate for extended
                                               inspect such equipment before being                     assistance during mine emergencies.                    periods of time to keep the mine from
                                               used.                                                      The petitioner asserts that the                     flooding.
                                                 (13) Within 60 days after the proposed                proposed alternative method will                          (2) Most anthracite mines work only
                                               decision and order (PDO) becomes final,                 provide the same measure of protection                 one shift per day, 5–6 days per week
                                               the petitioner will submit proposed                     afforded the miners under the existing                 during the colder months when coal
                                               revisions for its approved 30 CFR part                  standard.                                              sales are greatest, and may only work
                                               48 training plan to the District Manager.                  Docket Number: M–2017–032–C.                        2–3 days per week during the warmer
                                               These revisions will specify initial and                   Petitioner: M & D Anthracite Coal                   months because of lower coal sales.
                                               refresher training regarding the terms                  Company, 2030 East Center Street,                         (3) The vast majority of underground
                                               and conditions of the PDO.                              Tremont, Pennsylvania 17981.                           anthracite mines are small, employ 5 or
                                                 The petitioner asserts that application                  Mine: Slope #1 Mine, MSHA I.D. No.                  less miners underground, have very low
                                               of the existing standard will result in a               36–09976, located in Schuylkill County,                daily coal production of less than 25
                                               diminution of safety to the miners and                  Pennsylvania.                                          tons, and have never encountered a
                                               that the proposed alternative method                       Regulation Affected: 30 CFR 49.6(a)(1)              measurable quantity of methane during
                                               will at all times guarantee no less than                and (a)(5) (Equipment maintenance                      the life of the mine.
                                               the same measure of protection afforded                 requirements).                                            (4) Methane liberation in the few
                                               by the existing standard.                                  Modification Request: The petitioner                underground mines with a history of
                                                 Docket Number: M–2017–031–C.                          requests a modification of the existing                liberation occurs only when coal is shot
                                                 Petitioner: M & D Anthracite Coal                     standard to permit the reduction of                    from the solid and is dissipated by face
                                               Company, 2030 East Center Street,                       twelve self-contained oxygen breathing                 ventilation shortly thereafter.
                                               Tremont, Pennsylvania 17981.                            apparatus, to eight self-contained                        (5) Underground anthracite miners are
                                                 Mine: Slope #1 Mine, MSHA I.D. No.                    apparatus and the reduction of twelve                  significantly affected by natural
                                               36–09976, located in Schuylkill County,                 permissible cap lamps and charging                     ventilation that continues after the mine
                                               Pennsylvania.                                           rack to eight permissible cap lamps and                fan has been intentionally stopped
                                                 Regulation Affected: 30 CFR 49.2(b)                   charging rack.                                         during idle periods.
                                               (Availability of mine rescue teams).                       The petitioner states that:
                                                 Modification Request: The petitioner                                                                            (6) Accumulations of methane, in
                                                                                                          (1) A petition for modification of 30
                                               requests a modification of the existing                                                                        those underground mines with a history
                                                                                                       CFR 49.2(b) allowing the reduction of
                                               standard to permit the reduction of two                                                                        of liberation, are historically found in
                                                                                                       two rescue teams with five members
                                               mine rescue teams with five members                                                                            chutes and breasts (entries driven up the
                                                                                                       and one alternate each to two rescue
                                               and one alternate each to two mine                                                                             pitch) and are not yet connected to the
                                                                                                       teams of three members each with one
                                               rescue teams of three members each                                                                             adjacent return entry. These entries are
                                                                                                       alternate has been granted to all
                                               with one alternative for either team.                                                                          not affected by the natural ventilation
                                                                                                       operating anthracite coal mines.
                                                 The petitioner states that:                              (2) Eight self-contained breathing                  air currents.
                                                 (1) The underground mine is a small                   apparatus and eight permissible cap                       (7) The primary method of face
                                               mine and there is hardly enough                         lamps are sufficient to supply the seven               ventilation utilized in underground
                                               physical room to accommodate more                       members of the rescue team.                            anthracite mines is compressed air
                                               than three or four miners in the working                   The petitioner asserts that the                     movers with approved tubing in the
                                               places. An attempt to utilize five or                   proposed alternative method will at all                working place. They are shut off prior
                                               more rescue team members in the                         times guarantee no less than the same                  to the miners exiting the mine at the end
                                               mine’s confined working places would                    measure of protection afforded the                     of the shift and prior to the stoppage of
                                               result in a diminution of safety to both                miners under the existing standard.                    the main fan for the idle shifts.
                                               the miners at the mine and members of                                                                          Therefore, potential accumulation of
                                                                                                          Docket Number: M–2017–033–C.
                                               the rescue team.                                           Petitioner: M & D Anthracite Coal                   methane in the working face is unlikely
                                                 (2) Records of Mine Emergency                         Company, 2030 East Center Street,                      to be affected by natural ventilation
                                               responses over the last 20 years indicate               Tremont, Pennsylvania 17981.                           currents.
                                               that rescue and recovery operations                        Mine: Slope #1 Mine, MSHA I.D. No.                     (8) The mine’s pumping system
                                               conducted by Anthracite Underground                     36–09976, located in Schuylkill County,                typically consists of a submersible
                                               Rescue, Inc. (AUGR) have never utilized                 Pennsylvania.                                          pump located below the water level in
                                               more than one team. In addition, when                      Regulation Affected: 30 CFR                         the sump and a centrifugal pump
                                               one rescue team was utilized there were                 75.311(b)(2) and (b)(3) (Main mine fan                 located in the intake haulage slope
                                               no more than three rescue team                          operation).                                            above the active gangway level. The
                                               members traveling to a working place                       Modification Request: The petitioner                pumps are started and shut off by a set
                                               simultaneously.                                         requests a modification of the existing                of switches or electrodes located in the
                                                 (3) Employment in underground                         standard to permit the electrical circuits             sump. The switch/electrode located at
                                               anthracite mines has decreased                          entering the underground mine to                       the highest elevation in the sump will
ethrower on DSK3G9T082PROD with NOTICES




                                               substantially and the ratio of mine                     remain energized to the mine’s pumps,                  start the pumps when the water depth
                                               rescue teams to underground miners has                  while the main fan has been shut down                  increases to a pre-determined level to
                                               correspondingly been reduced. The loss                  during idle shifts when no miners are                  protect the active gangway level from
                                               of the underground work force                           working underground.                                   flooding. The pumps will continue to
                                               dramatically reduces the pool of                           The petitioner states that:                         operate until the water level depth
                                               qualified people available to fill mine                    (1) The mine requires pumping water                 decreases to the elevation of the lower
                                               rescue positions.                                       from the sump area of the intake                       switch/electrode.


                                          VerDate Sep<11>2014   19:00 Jan 19, 2018   Jkt 244001   PO 00000   Frm 00071   Fmt 4703   Sfmt 4703   E:\FR\FM\22JAN1.SGM   22JAN1


                                                                             Federal Register / Vol. 83, No. 14 / Monday, January 22, 2018 / Notices                                              3029

                                                 (9) Compliance with 30 CFR 75.311                        Regulation Affected: 30 CFR 75.335                     Regulation Affected: 30 CFR
                                               through the continuous operation of the                 (Seal strengths, design applications, and              75.1002(a) (Installation of electric
                                               main mine fan when pumps are                            installation).                                         equipment and conductors;
                                               energized would result in a diminution                     Modification Request: The petitioner                permissibility).
                                               of safety to the miners. During the                     requests a modification of the existing                   Modification Request: The petitioner
                                               colder months, the wet conditions                       standard to permit alternative methods                 requests a modification of the existing
                                               present in the intake haulage slope will                of construction employing wooden                       standard to permit the use of
                                               result in freezing and accumulations of                 material of moderate size and weight                   nonpermissible electric equipment
                                               ice creating a hazard to the miners                     due to the difficulty in accessing                     within 150 feet of the pillar line to
                                               riding the slope conveyance and to                      previously driven headings and breasts                 include drags and battery locomotives
                                               those miners who must manually chip                     containing the inaccessible abandoned                  due in part to the method of mining
                                               away the ice in the pitching slope                      workings through the use of homemade                   used in pitching anthracite mines and
                                               thereby increasing a fall hazard. The                   ladders. Additionally, a design criterion              the alternative hourly evaluation of the
                                               amount of ice accumulations during a                    in the 10-psi range should be accepted                 mine air quality for methane during
                                               single shift of production is usually                   due to the non-explosibility of                        operation with one of the gas test results
                                               minimal and can be melted during the                    anthracite coal dust and minimal                       to be recorded in the on-shift
                                               idle shifts, with the main fan off, as the              potential for either an accumulation of                examination record. Petitioner also
                                               natural ventilating air current is warmed               methane in previously mined pitching                   proposes to suspend equipment
                                               by the higher underground temperatures                  veins or an ignition source in the gob                 operation anytime methane
                                               and carried through slope.                              area, and that seals installed in pairs                concentration at the equipment reaches
                                                 (10) The mine operator proposes to                    permit the water trap to be installed                  0.5 percent either during operation or
                                               initiate the following alternatives to                  only in the gangway seal (lowest                       when found during a pre-shift
                                               ensure the safety of the miners:                        elevation) and sampling tube in the                    examination.
                                                 (a) The examiner will determine                       monkey (higher elevation) seal.                           The petitioner states that:
                                               whether the pumps are operating and if                     The petitioner states that:                            (1) The equipment will be operated in
                                               the natural ventilation air current is                     (1) The required transportation of                  the working section’s only intake entry
                                               moving in the proper direction prior to                 solid concrete blocks or equivalent                    (gangway) which is regularly traveled
                                               energizing the main mine fan and before                 materials manually on ladders on                       and examined.
                                               starting the required pre-shift                         pitching anthracite veins will expose                     (2) The use of drags on less than
                                               examination.                                            miners to greater hazards such as                      moderate pitching veins (less than 20
                                                 (b) In the cases where the pumps are                  falling, being struck by falling materials,            degrees pitch) is the only practical
                                               not operating when the examiner                         or resulting strains or sprains due to the             system of mining in use.
                                               arrives, the examiner will deenergize                   weight of the materials.                                  (3) Permissible drags are not
                                               the pump circuits before starting the                      (2) No evidence of ignition in                      commercially available and, due in part
                                               main mine fan and will allow the fan to                 accessible abandoned anthracite                        to their small size, permissible
                                               operate for 30 minutes prior to entering                workings has been found to date.                       locomotives are not commercially
                                               the mine to conduct the pre-shift                          (3) In veins pitching greater than 45               available.
                                                                                                                                                                 (4) As result of low daily production
                                               examination.                                            degrees, the weight of the seal is
                                                                                                                                                              rates and full timbering support, in-
                                                 (c) During the pre-shift examination,                 transferred to the low side rib (coal).
                                                                                                                                                              rushes of methane due to massive pillar
                                               when no accumulation of methane is                         (4) Irregularly shaped anthracite
                                                                                                                                                              falls are unlikely to occur.
                                               found in the vicinity of the pumps, the                 openings would require substantial                        (5) Recovery of the pillars above the
                                               pump circuits may be energized before                   cutting of rectangular blocks to ensure                first miner heading is usually
                                               the miners travel underground.                          proper tie-in to hitches in the top rock,              accomplished on the advance within
                                                 (d) In those cases where the pumps                    bottom rock, and low side coal rib.                    150 feet of the section intake (gangway)
                                               are found to be already in operation                       (5) Concrete block and mortar                       and the remaining minable pillars
                                               because of high water levels and when                   construction for openings parallel to the              recovered from the deepest point of
                                               the natural ventilating currents are                    pitching vein would be almost                          penetration outby.
                                               moving in the proper direction, the                     impossible to construct and subject to                    (6) The 5,000 cfm of required intake
                                               main mine fan will be started and run                   failure by its own weight.                             air flow is measured just outby the
                                               for 30 minutes before entering the mine                    (6) Isolation of inaccessible                       nonpermissible equipment with the
                                               to conduct a pre-shift examination.                     abandoned workings from an active                      ventilating air passing over the
                                               Examination of the mine pump                            section will permit natural venting of                 equipment to ventilate the pillar being
                                               installation will be completed prior to                 any potential methane build-up through                 mined.
                                               entering the active gangway level                       surface breeches, and the mine has not                    (7) The nonpermissible electrical
                                               working and before continuing the pre-                  experienced measurable liberation of                   equipment is attended during operation
                                               shift examination.                                      methane to-date.                                       and either power to the unit will be
                                                 The petitioner asserts that the                          The petitioner asserts that the                     deenergized at the intersection of the
                                               proposed alternative method will                        proposed alternative method will                       working gangway and intake slope or
                                               provide no less than the same measure                   provide no less than the same measure                  the equipment will be moved to that
                                               of protection afforded the miners under                 of protection afforded the miners under                area when production ceases, thereby,
                                               the existing standard.                                  the existing standard.                                 minimizing any ignition potential from
ethrower on DSK3G9T082PROD with NOTICES




                                                 Docket Number: M–2017–034–C.                             Docket Number: M–2017–035–C.                        the pillar recovery area.
                                                 Petitioner: M & D Anthracite Coal                        Petitioner: M & D Anthracite Coal                      (8) Where more than one active line
                                               Company, 2030 East Center Street,                       Company, 2030 East Center Street,                      of pillar breast recovery exists, the
                                               Tremont, Pennsylvania 17981.                            Tremont, Pennsylvania 17981.                           locomotive may travel to a point just
                                                 Mine: Slope #1 Mine, MSHA I.D. No.                       Mine: Slope #1 Mine, MSHA I.D. No.                  outby the deepest active chute/breast
                                               36–09976, located in Schuylkill County,                 36–09976, located in Schuylkill County,                (room) workings or last open crosscut in
                                               Pennsylvania.                                           Pennsylvania.                                          a developing set of entries.


                                          VerDate Sep<11>2014   19:00 Jan 19, 2018   Jkt 244001   PO 00000   Frm 00072   Fmt 4703   Sfmt 4703   E:\FR\FM\22JAN1.SGM   22JAN1


                                               3030                          Federal Register / Vol. 83, No. 14 / Monday, January 22, 2018 / Notices

                                                  The petitioner asserts that the                        (7) Where potential hazards exist and                   Regulation Affected: 30 CFR
                                               proposed alternative method will                        in-mine drilling capabilities limit                    75.1400(c) (Hoisting equipment;
                                               provide no less than the same measure                   penetration, surface boreholes may be                  general).
                                               of protection afforded the miners under                 used to intercept the workings and                        Modification Request: The petitioner
                                               the existing standard.                                  results analyzed prior to the beginning                requests a modification of the existing
                                                  Docket Number: M–2017–037–C.                         of mining in the affected area.                        standard to permit the gunboat to
                                                  Petitioner: M & D Anthracite Coal                      The petitioner asserts that the                      transport persons without safety catches
                                               Company, 2030 East Center Street,                       proposed alternative method will                       or other no less effective devices
                                               Tremont, Pennsylvania 17981.                            provide no less than the same measure                  because to date, no such safety catch or
                                                  Mine: Slope #1 Mine, MSHA I.D. No.                   of protection afforded the miners under                device is available for steeply pitching
                                               36–09976, located in Schuylkill County,                 the existing standard.                                 and undulating slopes with numerous
                                               Pennsylvania.                                             Docket Number: M–2017–038–C.                         curves and knuckles present in the main
                                                  Regulation Affected: 30 CFR                            Petitioner: M & D Anthracite Coal                    haulage slopes of Anthracite mines, that
                                               75.1200(d) and (i) (Mine map).                          Company, 2030 East Center Street,                      range in length from 30 to 4200 feet and
                                                  Modification Request: The petitioner                 Tremont, Pennsylvania 17981.                           vary in pitch from 12 degrees and 75
                                               requests a modification of the existing                   Mine: Slope #1 Mine, MSHA I.D. No.                   degrees.
                                               standard to permit the substitution of                  36–09976, located in Schuylkill County,                   The petitioner states that:
                                               cross-sections in lieu of contour lines                 Pennsylvania.                                             (1) A functional safety catch has not
                                               through the intake slope, at locations of                 Regulation Affected: 30 CFR 75.1202–                 been developed. Makeshift devices, if
                                               rock tunnel connections between veins,                  1(a) (Temporary notations, revisions and               installed, could be activated on
                                               and at 1,000 feet intervals of advance                  supplements).                                          knuckles and curves when no
                                               from the intake slope and to limit the                    Modification Request: The petitioner                 emergency exists causing a tumbling
                                               required mapping of mine workings                       requests a modification of the existing                effect on the conveyance which would
                                               above and below to those present within                 standard to permit the required interval               increase rather than decrease the hazard
                                               100 feet of the vein(s) being mined                     of survey to be on an annual basis from                to miners.
                                               unless these veins are interconnected to                the initial survey in lieu of the current                 (2) As an alternative, the petitioner
                                               other veins beyond the 100 feet limit,                  interval of not more than 6 months.                    proposes to operate the man cage or
                                               through rock tunnels.                                     The petitioner proposes to continue to               steel gunboat with secondary safety
                                                  The petitioner states that:                          update the mine map by hand notations                  connections securely fastened around
                                                  (1) Due to steep pitch encountered in                                                                       the gunboat and to the hoisting rope
                                                                                                       on a daily basis and conduct subsequent
                                               mining anthracite coal veins, contours                                                                         above the main connecting device and
                                                                                                       surveys prior to commencing retreat
                                               provide no useful information and their                                                                        use hoisting ropes having a factor of
                                                                                                       mining, and when either a drilling
                                               presence would make portions of the                                                                            safety in excess of the 4 to 8 to 1 as
                                                                                                       program is required by 30 CFR 75.388
                                               map illegible.                                                                                                 suggested in the American Standards
                                                  (2) The vast majority of current                     or a plan for mining into inaccessible
                                                                                                       areas is required by 30 CFR 75.389.                    Specifications for Use of Wire Ropes for
                                               underground anthracite mining involves
                                                                                                         The petitioner states that:                          Mines.
                                               either second mining of remnant pillars
                                                                                                         (1) The low production and slow rate                    The petitioner asserts that the
                                               from previous mining/mine operators or
                                                                                                       of advance in anthracite mining make                   proposed alternative method will
                                               the mining of veins of lower quality in
                                                                                                       surveying on 6-month intervals                         provide no less than the same measure
                                               proximity to inaccessible and frequently
                                                                                                       impractical. The mine operates using                   of protection afforded the miners under
                                               flooded abandoned mine workings
                                                                                                       non-mechanized, hand-loading mining                    the existing standard.
                                               which may or may not be mapped.
                                                  (3) All mapping for mines above and                  methods. In most cases, annual                            Docket Number: M–2017–040–C.
                                               below will be researched by a contract                  development is frequently limited to                      Petitioner: Mountain Coal Company,
                                               engineer for the presence of                            less than 500 feet of gangway advance                  LLC, 5174 Hwy. 133, Somerset, CO
                                               interconnecting rock tunnels between                    with associated up-pitch development.                  81434.
                                               veins in relation to the mine and a                       (2) Development above the active                        Mine: West Elk Mine, MSHA I.D. No.
                                               hazard analysis done when mapping                       gangway is designed to mine into the                   05–03672, located in Gunnison County,
                                               indicates the presence of known or                      level above at designated intervals                    Colorado.
                                               potentially flooded workings.                           thereby maintaining sufficient control                    Regulation Affected: 30 CFR
                                                  (4) Mine workings found to exist                     between both surveyed gangways.                        75.364(b)(2) (Weekly examination).
                                               beyond 100 feet from the mine, when no                    (3) The available engineering/                          Modification Request: The petitioner
                                               rock tunnel connections are found, will                 surveyor resources are limited in the                  requests a modification of the existing
                                               be recognized as presenting no hazard to                anthracite coal fields. Surveying on an                standard that requires at least one entry
                                               the mine due to the pitch of the vein                   annual basis is difficult to achieve with              of each return air course to be traveled
                                               and rock separation between.                            four individual contractors currently                  and examined in its entirety at least
                                                  (5) Additionally, the mine workings                  available.                                             every 7 days by a certified person. The
                                               above and below are usually inactive                      The petitioner asserts that the                      petitioner proposes to establish multiple
                                               and abandoned and therefore, not                        proposed alternative method will                       inlet and outlet evaluation points to
                                               subject to changes during the life of the               provide no less than the same measure                  measure and evaluate at least every 7
                                               mine.                                                   of protection afforded the miners under                days the air quality, air quantity, and air
                                                  (6) Where evidence indicates prior                   the existing standard.                                 direction of all air entering and leaving
ethrower on DSK3G9T082PROD with NOTICES




                                               mining was conducted on a vein above                      Docket Number: M–2017–039–C.                         the Sly Gulch South Mains Return in
                                               or below and research exhausts the                        Petitioner: M & D Anthracite Coal                    lieu of traveling one of the affected
                                               availability of mine mapping, the vein                  Company, 2030 East Center Street,                      entries. The petitioner states that:
                                               will be considered to be mined and                      Tremont, Pennsylvania 17981.                              (1) Multiple roof falls and floor heave
                                               flooded and appropriate precautions                       Mine: Slope #1 Mine, MSHA I.D. No.                   within the proposed evaluation area
                                               taken, as required by 30 CFR 75.388,                    36–09976, located in Schuylkill County,                limits the entries that can be traveled by
                                               where possible.                                         Pennsylvania.                                          the weekly examiner. Some of the


                                          VerDate Sep<11>2014   19:00 Jan 19, 2018   Jkt 244001   PO 00000   Frm 00073   Fmt 4703   Sfmt 4703   E:\FR\FM\22JAN1.SGM   22JAN1


                                                                             Federal Register / Vol. 83, No. 14 / Monday, January 22, 2018 / Notices                                             3031

                                               traveled entries require the weekly                     DEPARTMENT OF LABOR                                    docket, go to http://www.regulations.gov
                                               examiner to crawl on his hands and                                                                             or the OSHA Docket Office at the above
                                               knees, preventing quick egress if                       Occupational Safety and Health                         address. All documents in the docket
                                               necessary.                                              Administration                                         (including this Federal Register notice)
                                                  (2) All air entering and leaving the                 [Docket No. OSHA–2011–0066]                            are listed in the http://
                                                                                                                                                              www.regulations.gov index; however,
                                               affected area can be measured and
                                                                                                       Vertical Tandem Lifts (VTLs) for Marine                some information (e.g., copyrighted
                                               evaluated safely from the proposed inlet
                                                                                                       Terminals; Extension of the Office of                  material) is not publicly available to
                                               and outlet evaluation points shown on                                                                          read or download through the website.
                                                                                                       Management and Budget’s (OMB)
                                               the drawing attached to this petition.                                                                         All submissions, including copyrighted
                                                                                                       Approval of Information Collection
                                               Access to the proposed inlet and outlet                                                                        material, are available for inspection
                                                                                                       (Paperwork) Requirements
                                               evaluation points is not hindered by                                                                           and copying at the OSHA Docket Office.
                                               roof falls or excessive floor heave,                    AGENCY:  Occupational Safety and Health                You may also contact Theda Kenney at
                                               allowing quick egress if necessary.                     Administration (OSHA), Labor.                          the address below to obtain a copy of
                                                  (3) There are no seals or electrical                 ACTION: Request for public comments.                   the ICR.
                                               installations within the proposed                       SUMMARY:    OSHA solicits public                       FOR FURTHER INFORMATION CONTACT:
                                               evaluation area that must be examined.                  comments concerning its proposal to                    Charles McCormick or Theda Kenney,
                                                  (4) In lieu of traveling one of the                  extend the Office of Management and                    Directorate of Standards and Guidance,
                                               return entries in the proposed                          Budget’s (OMB) approval of the                         OSHA, U.S. Department of Labor,
                                               evaluation area, at least every 7 days, a               information collection requirements                    telephone (202) 693–2222.
                                               certified person will:                                  specified in the Vertical Tandem Lifts                 SUPPLEMENTARY INFORMATION:
                                                                                                       (VTLs) for Marine Terminals.
                                                  (a) Measure the air quantity at each                                                                        I. Background
                                                                                                       DATES: Comments must be submitted
                                               inlet and outlet evaluation point. If the                                                                        The Department of Labor, as part of its
                                                                                                       (postmarked, sent, or received) by
                                               combined air quantity at the outlet                                                                            continuing effort to reduce paperwork
                                                                                                       March 23, 2018.
                                               evaluation points differs by more than                                                                         and respondent (i.e., employer) burden,
                                                                                                       ADDRESSES:
                                               20 percent from the combined air                           Electronically: You may submit                      conducts a preclearance consultation
                                               quantity at the inlet evaluation points,                comments and attachments                               program to provide the public with an
                                               ventilation controls surrounding the                    electronically at: http://                             opportunity to comment on proposed
                                               affected area will be examined from the                 www.regulations.gov, which is the                      and continuing information collection
                                               outby side and corrective measures will                 Federal eRulemaking Portal. Follow the                 requirements in accord with the
                                               be implemented to repair the affected                   instructions online for submitting                     Paperwork Reduction Act of 1995 (PRA)
                                               ventilation controls to restore the                     comments.                                              (44 U.S.C. 3506(c)(2)(A)). This program
                                               differential air quantities to within 20                   Facsimile: If your comments,                        ensures that information is in the
                                               percent.                                                including attachments, are not longer                  desired format, reporting burden (time
                                                                                                       than 10 pages, you may fax them to the                 and cost) is minimal, collection
                                                  (b) Measure the air quality at each
                                                                                                       OSHA Docket Office at (202) 693–1648.                  instruments are clearly understood, and
                                               inlet and outlet evaluation point. Both
                                                                                                          Mail, hand delivery, express mail,                  OSHA’s estimate of the information
                                               the methane and oxygen concentrations                                                                          collection burden is accurate. The
                                                                                                       messenger, or courier service: When
                                               will be measured. Methane                                                                                      Occupational Safety and Health Act of
                                                                                                       using this method, you must submit a
                                               concentrations at the inlet and outlet                                                                         1970 (the OSH Act) (29 U.S.C. 651 et
                                                                                                       copy of your comments and attachments
                                               evaluation points will be a minimum of                  to the OSHA Docket Office, Docket No.                  seq.) authorizes information collection
                                               19.5 percent.                                           OSHA–2011–0066, Occupational Safety                    by employers as necessary or
                                                  (c) Verify the proper air direction as               and Health Administration, U.S.                        appropriate for enforcement of the OSH
                                               indicated on the drawing at each inlet                  Department of Labor, Room N–3653,                      Act or for developing information
                                               and outlet evaluation point.                            200 Constitution Avenue NW,                            regarding the causes and prevention of
                                                                                                       Washington, DC 20210. Deliveries                       occupational injuries, illnesses, and
                                                  (d) Record the air quantity, air quality,
                                                                                                       (hand, express mail, messenger, and                    accidents (29 U.S.C. 657). The OSH Act
                                               and a notation of proper air direction at
                                                                                                       courier service) are accepted during the               also requires that OSHA obtain such
                                               each inlet and outlet evaluation point in
                                                                                                       Department of Labor’s and Docket                       information with minimum burden
                                               the weekly examination book.                                                                                   upon employers, especially those
                                                                                                       Office’s normal business hours, 10:00
                                                  The petitioner asserts that the                      a.m. to 3:00 p.m., E.T.                                operating small businesses, and to
                                               proposed alternative method will at all                    Instructions: All submissions must                  reduce to the maximum extent feasible
                                               times guarantee no less than the same                   include the Agency name and OSHA                       unnecessary duplication of effort in
                                               measure of protection as that afforded                  docket number (OSHA–2011–0066) for                     obtaining information (29 U.S.C. 657).
                                               by the existing standard and that                       the Information Collection Request                       The VTL Standard for Marine
                                               traveling one of the affected entries                   (ICR). All comments, including any                     Terminals (29 CFR part 1917) specifies
                                               results in a diminution of safety.                      personal information you provide, are                  the following collection of information
                                                                                                       placed in the public docket without                    requirements. The purpose of each of
                                               Sheila McConnell,                                       change, and may be made available                      these requirements is to provide
                                               Director, Office of Standards, Regulations,             online at http://www.regulations.gov.                  workers with safe work practices when
ethrower on DSK3G9T082PROD with NOTICES




                                               and Variances.                                          For further information on submitting                  conducting VTLs.
                                               [FR Doc. 2018–01008 Filed 1–19–18; 8:45 am]             comments, see the ‘‘Public                               Paragraph (i)(8)(iv) of § 1917.71
                                               BILLING CODE 4520–43–P                                  Participation’’ heading in the section of              requires employers to ensure that the
                                                                                                       this notice titled SUPPLEMENTARY                       interbox connectors used in VTLs have
                                                                                                       INFORMATION.                                           been certified by a competent authority
                                                                                                          Docket: To read or download                         authorized under § 1918.11 (for interbox
                                                                                                       comments or other material in the                      connectors that are part of a vessel’s


                                          VerDate Sep<11>2014   19:00 Jan 19, 2018   Jkt 244001   PO 00000   Frm 00074   Fmt 4703   Sfmt 4703   E:\FR\FM\22JAN1.SGM   22JAN1



Document Created: 2018-01-23 21:36:01
Document Modified: 2018-01-23 21:36:01
CategoryRegulatory Information
CollectionFederal Register
sudoc ClassAE 2.7:
GS 4.107:
AE 2.106:
PublisherOffice of the Federal Register, National Archives and Records Administration
SectionNotices
ActionNotice.
DatesAll comments on the petitions must be received by MSHA's Office of Standards, Regulations, and Variances on or before February 21, 2018.
ContactBarbara Barron, Office of Standards, Regulations, and Variances at 202-693-9447 (Voice), [email protected] (Email), or 202-693-9441 (Facsimile). [These are not toll-free numbers.]
FR Citation83 FR 3027 